My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1418 W St Anne Pl & Unit# 2 - 101122594 & 101122596 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Anne Pl
>
1418 W St Anne Pl
>
1418 W St Anne Pl & Unit# 2 - 101122594 & 101122596 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:44:35 PM
Creation date
8/6/2025 9:48:20 AM
Metadata
Fields
Template:
Plan
Permit Number
101122594
101122596
Full Address
1418 W St Anne Pl
1418 W St Anne Pl Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2022 Single-Family Residential Mandatory Requirements Summary <br />5/6/22 <br /> <br /> <br /> <br /> <br />§ 150.0(m)13: <br />Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have <br />a hole for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must <br />be ≥ 350 CFM per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air <br />handlers and ≤ 0.58 watts per CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal <br />cooling capacity, and an air-handling unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with <br />Reference Residential Appendix RA3.3. * <br /> <br /> <br />Ventilation and Indoor Air Quality: <br />§ 150.0(o)1: Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, <br />Ventilation and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1. * <br />§ 150.0(o)1B: Central Fan Integrated (CFI) Ventilation Systems. Continuous operation of CFI air handlers is not allowed to provide the whole- <br />dwelling unit ventilation airflow required per §150.0(o)1C. A motorized damper(s) must be installed on the ventilation duct(s) that <br />prevents all airflow through the space conditioning duct system when the damper(s) is closed andcontrolled per §150.0(o)1Biii&iv. CFI <br />ventilation systems must have controls that track outdoor air ventilation run time, and either open or close the motorized damper(s) for <br />compliance with §150.0(o)1C. <br /> <br />§ 150.0(o)1C: <br />Whole-Dwelling Unit Mechanical Ventilation for Single-Family Detached and townhouses . Single-family detached dwelling units, <br />and attached dwelling units not sharing ceilings or floors with other dwelling units, occupiable spaces, public garages, or commercial <br />spaces must have mechanical ventilation airflow specified in § 150.0(o)1Ci-iii. <br />§ 150.0(o)1G: Local Mechanical Exhaust. Kitchens and bathrooms must have local mechanical exhaust; nonenclosed kitchens must have demand- <br />controlled exhaust system meeting requirements of §150.0(o)1Giii,enclosed kitchens and bathrooms can use demand-controlled or <br />continuous exhaust meeting §150.0(o)1Giii-iv. Airflow must be measured by the installer per §150.0(o)1Gv, and rated for sound per <br />§150.0(o)1Gvi. * <br />§ 150.0(o)1H&I: Airflow Measurement and Sound Ratings of Whole-Dwelling Unit Ventilation Systems. The airflow required per § 150.0(o)1C must <br />be measured by using a flow hood, flow grid, or other airflow measuring device at the fan’s inlet or outlet terminals/grilles per Reference <br />Residential Appendix RA3.7. Whole-Dwelling unit ventilation systems must be rated for sound per ASHRAE 62.2 §7.2 at no less than the <br />minimum airflow rate required by §150.0(o)1C. <br /> <br />§ 150.0(o)2: Field Verification and Diagnostic Testing. Whole-Dwelling Unit ventilation airflow, vented range hood airflow and sound rating, <br />and HRV and ERV fan efficacy must be verified in accordance with Reference Residential Appendix RA3.7. Vented range hoods <br />must be verified per Reference Residential Appendix RA3.7.4.3 to confirm if it is rated by HVI or AHAM to comply with the airflow <br />rates and sound requirements per §150.0(o)1G <br />Pool and Spa Systems and Equipment: <br /> <br />§ 110.4(a): <br />Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: compliance with the Appliance Efficiency Regulations and listing in MAEDbS; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating. * <br />§ 110.4(b)1: Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. <br />§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. <br />§ 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. <br />§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. <br />§ 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves. * <br />Lighting: <br /> <br />§ 110.9: <br />Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable <br />requirements of § 110.9. * <br />§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A, except lighting integral to exhaust fans, kitchen <br />range hoods, bath vanity mirrors, and garage door openers; navigation lighting less than 5 watts; and lighting internal to drawers, cabinets, and linen <br />closets with an efficacy of at least 45 lumens per watt. <br />§ 150.0(k)1B: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8. * <br />§ 150.0(k)1C: Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must not contain screw based sockets, must be airtight, <br />and must be sealed with a gasket or caulk. California Electrical Code § 410.116 must also be met. <br />§ 150.0(k)1D: Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires. <br />§ 150.0(k)1E: Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or other device shall be no more than the number of bedrooms. These boxes must be served by a dimmer, vacancy sensor control, low voltage wiring, or fan speed control. <br />§ 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k). *
The URL can be used to link to this page
Your browser does not support the video tag.