Laserfiche WebLink
AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-1 <br />PROJECT INFORMATION/SCOPE OF WORK <br />VICINITY MAP <br />SHEET INDEX <br />APPLICABLE CODES <br />PLAN SET LEGEND <br />SUB SERVICE PANEL <br />AC DISCONNECT <br />DC DISCONNECT <br />SOLAR COMBINER BOX <br />INVERTER <br />SUB <br />AC <br />DC <br />SLC <br />INV <br />JUNCTION BOXJB <br />ABBREVIATIONS <br />EXTERIOR <br />INTERIOR <br />EXT <br />INT <br />NEW(N) <br />EXISTING(E) <br />ELECTRICAL METALLIC TUBINGEMT <br />RIGID METALLIC CONDUITRMC <br />VOLTAGE OPEN CIRCUITVOC <br />VOLTAGE AT MAX. POWERVMP <br />SHORT CIRCUIT CURRENTISC <br />CURRENT AT MAX. POWERIMP <br />AHJ NOTES <br />PV MONITORINGM <br />NOT TO SCALENTS <br />MAIN SERVICE PANELMSP <br />PROJECT INFORMATIONPV-1 PROJECT INFORMATION <br />PV-1A SITE PLAN, HOUSE PHOTO <br />PV-1B FIRE ACCESS PATHWAY PLAN <br />PV-2 ROOF PLAN <br />PV-2A ATTACHMENT DETAILS <br />PV-2B BATTERY DETAILS <br />PV-3 ELECTRICAL LINE DIAGRAM & <br /> ELECTRICAL CALCULATIONS <br />PV-3A ELECTRICAL NOTES <br />PV-4 & 4A REQUIRED SIGNAGE <br />ENPHASE AC SOLAR PVENCOMBINER BOX <br />PROJECT SITE <br />FLEXIBLE METALLIC CONDUITFMC <br />PERFORMANCE METER <br />STORAGE BATTERYBAT <br />PLP PROTECTED LOAD <br />PANEL <br />AUTHORITY HAVINGAHJ <br />JURISDICTION <br />RIGID GALVANIZED STEELRGS <br />ENERGY STORAGEESS <br />SYSTEM <br />14 X 400 W <br />LONGL GUHHQ EQHUJ\ THFKQRORJ\ <br />CR., LWG. LR5-54HABB-400M <br />ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES <br />14 X 290 W <br />EQSKDVH EQHUJ\ IQ8PLUS-72-2-US <br />(SI1-JUN20) (240V) <br />SYSTEM SIZE:5.600 NW DC STC, 5.083 NW CEC-AC <br />ARRAY AREA:294 SF <br />PANEL <br />UPGRADE:225 A <br />AHJ:CITY OF SANTA ANA <br />APN:001-055-05 <br />ROBERTO DOMINGUEZ <br />1422 MARION WAY WEST <br />SANTA ANA, CA 92706 <br />INSTALLATION OF NEW SOLAR PV & ESS SYSTEM: <br />ALL WORK TO COMPLY WITH <br />THE FOLLOWING CODES: <br />2022 CA BUILDING CODE <br />2022 CA RESIDENTIAL CODE <br />2022 CA MECHANICAL CODE <br />2022 CA ELECTRICAL CODE <br />2022 CA GREEN CODE <br />2022 CA PLUMBING CODE <br />2022 CA ENERGY CODE <br />2022 CA FIRE CODE <br />LOCAL JURISDICTION AMENDMENTS <br />GAT TESLA BACKUP <br />GATEWAY 2 <br />1 X TESLA BACKUP GATEWAY 2 <br />LATITUDE 33.767250 - LONGITUDE -117.887090 <br />OCCUPANCY: R-3 <br />CONSTRUCTION TYPE: VB <br />UNSPRINKLERED <br />1 X TESLA POWERWALL 3 BATTERY <br />PER SECTION R314 AND R315 OF CRC 2022, IT'S REQUIRED THAT <br />SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE <br />RETROFITTED INTO THE EXISTING DWELLING FOR A PERMIT <br />WITH REPAIRS OR ADDITIONS EXCEEDING 1,000. <br />ALL NEW UTILITY CONNECTIONS ARE REQUIRED TO BE <br />INSTALLED BELOW GRADE BY SANTA ANA MUNICOPAL CODE <br />41-626(B). THERE IS A STANDING EXCEPTION FOR EXISTING ONE <br />AND TWO FAMILY DWELLINGS. THIS EXCEPTION APPLIES ONLY <br />WHEN THE NEW ELECTRICAL SERVICE IS DESIGNATED TO BE <br />FED FROM BELOW GRADE AS WELL AS OVERHEAD. <br />ONLY LISTED COMBINATION OVERHEAD AND UNDERGROUND <br />FEED SERVICE BOXES MAY BE USED TO CONNECT TO AN <br />OVERHEAD UTILITY DROP. THIS EXCEPTION TO AN <br />UNDERGROUND FED SERVICE APPLIES ONLY TO EXISTING <br />SINGLE FAMILY AND TWO FAMILY RESIDENCES. <br />1422 W Marion <br />Way1/24/2025