Laserfiche WebLink
AB--ISSUED FOR: PERMITDATE:SRODU PKRWRYROWDLF S\VWHP11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 IQGLDQD AYHQXH, SXLWH 2RLYHUVLGH, CA 92503PKRQH: (866) 464-8968CSLB 997054 (B,C-10,C-46,C-39)XBBBBBBBBBBBBBBBBBBBBBBBGUYOU CONSTRUCTION,INC.PV-3AELECTRICAL NOTESELECTRICAL NOTES <br />PER 2022 CEC, 690.64 (B)(7): LOCATE INVERTER OUTPUT AS FAR AS POSSIBLE FROM NORMAL POWER <br />SUPPLY AT SERVICE PANEL. RELOCATION OF EXISTING CIRCUITS MAY BE NEEDED. DO NOT CHANGE <br />PHASING OF MULTI-WIRE CIRCUITS. PERMANENT SIGNAGE AT PV SUPPLY CIRCUIT BREAKERS MUST <br />SAY: WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. <br />SIGNAGE TO BE LOCATED ADJACENT TO BACKFED BREAKER. <br />ADDITIONAL AHJ REQUIRED ELECTRICAL NOTES <br />1. PV ARRAYS ARE PER SINGLE LINE.. <br />2. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO <br />CONDUIT WIRING. <br />3. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE <br />GROUND ELECTRODE PER CEC 250.58. <br />4. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. <br />5. CONNECTORS SHALL BE POLARIS OR EUROSTRIP IT CONNECTORS. <br />6. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHED CUT SHEET. <br />7. AC DISCONNECT SHALL BE PER SINGLE LINE. <br />8. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO CEC 690. <br />9. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT <br />SHALL BE THWN-2. <br />10. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5 <br />11. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. <br />12. ALL WORK TO COMPLY WITH 2022 CALIFORNIA ELECTRIC CODE, 2022 CALIFORNIA BUILDING <br />CODE <br />13. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. <br />14. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED <br />FROM SOLAR ARRAY. <br />15. CONDUCTORS ON ROOF ARE TO BE A MINIMUM OF 7/8" OFF OF THE ROOF SURFACE. <br />16.GEC TO BE CONNECTED TO EXISTING UFER. IF UFER IS NOT PRESENT THEN A NEW <br />GROUND ROD WILL BE ADDED FOR GROUNDNG PURPOSES. <br />17. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS <br />WHITE. <br />18. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE SMALLER THAN 14 AWG. <br />19. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS <br />LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE <br />MADE AS PERMITTED. <br />RACKING & MODULES ARE CONNECTED TO THE EGC W/ UNIRAC NXT UMOUNT LUG. MODULES <br />ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS <br />DC SIDE OF ARRAY IS UNGROUNDED AND THEREFORE GEC IS NOT REQUIRED. <br />ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH <br />ARTICLE 250. <br />ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES <br />LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES PER CEC 690.9 <br />(A) <br />GROUNDING: <br />UNIRAC NXT UMOUNT LUG <br />UL LISTED 2703 <br />1422 W Marion <br />Way1/24/2025