Laserfiche WebLink
AB1/9/2025-ISSUED FOR: PERMITDATE:Solar Photovoltaic System11/26/2024ROBERTO DOMINGUEZ1422 MARION WAY WESTSANTA ANA, CA 9270624-1937(714)-742-42569880 Indiana Avenue, Suite 2Riverside, CA 92503Phone: (866) 464-8968CSLB #997054 (B,C-10,C-46,C-39)X_______________________GUYOU CONSTRUCTION,INC.PV-4REQUIRED SIGNAGEFRONT OF HOME <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS <br />LOCATED AS SHOWN: <br />SOLAR ARRAY <br /> MAP PLACARD ON FACE OF THE MAIN SERVICE PANEL <br />PER CEC 705.10: <br />MSP6 <br />MARION WAY WEST <br />1422 MARION WAY WESTSANTA ANA, CA 92706 <br />YOU ARE <br />HERE <br /> ON THE FACE OF THE MAIN SERVICE <br />DISCONNECT PER CEC 690.13(B): <br />PV SYSTEM <br />DISCONNECT <br />THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM <br />OF 3/8" HIGH LETTERING, IN ARIAL FONT <br />(NON-BOLD), WITH CAPITAL LETTERS, WHITE ON <br />RED BACKGROUND AND ON A REFLECTIVE, <br />WEATHER RESISTANT MATERIAL. <br /> ON FACE OF THE SERVICE METER PANEL: <br />SIGNAGE AT MAIN SERVICE PANEL: <br />MSP1 <br />MSP2 <br />MSP5 <br />MSP3 <br />MAXIMUM AC OPERATING CURRENT = 16.94A <br />MAXIMUM AC OPERATING VOLTAGE = 240V <br />RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM <br /> ON FACE OF THE SERVICE METER PANEL PER <br />CEC 690.56 (C)(1)(a): <br />SOLAR PV SYSTEM <br />EQUIPPED WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE SHOCK <br />HAZARD IN ARRAY <br />SOLAR PV SYSTEM IS EQUIPPED WITH RAPID <br />SHUTDOWN" SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT OF 3/8" <br />IN BLACK ON YELLOW BACKGROUND, AND THE <br />REMAINING CHARACTERS SHALL BE <br />CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16" <br />IN BLACK ON WHITE BACKGROUND. <br /> ON RAPID SHUTDOWN SWITCH LOCATED ON OR WITHIN <br />3' FROM SWITCH, IN 38" LETTERS IN WHITE ON RED <br />BACKGROUND ON A REFLECTIVE LABEL PER CEC 690.56 <br />(C)(3): <br />MSP4 <br />WARNING <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />LOCATED AT BACKFED BREAKER PER CEC <br />705.12(B)(2)(3)(b): <br />MSP7 ON FACE OF THE SERVICE METER PANEL <br />PER CEC 705.10: <br />CAUTION <br />MULTIPLE SOURCES OF POWER <br />SERVICE POINT & <br />UTILITY METERING <br />BATTERY <br />DISCONNECT <br />MSP8 <br />WARNING <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES <br />TOTAL RATING OF ALL OVERCURRENT DEVICES <br />EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF BUSBAR <br />LOCATED AT MAIN SERVICE PANEL PER CEC <br />705.12(B)(3)(3):PV DISCONNECT <br />PROTECTED LOAD PANEL <br />GATEWAY <br />PV COMBINER <br />BOX <br />STORAGE <br />BATTERY <br />A <br />1422 W Marion <br />Way1/24/2025