Laserfiche WebLink
PAGE <br />REV: A 9/28/2024 <br />MONICA WILLIAMS <br />1730 W RICHLAND AVE, SANTA <br />ANA, CA, 92703 <br />PROJECT NUMBER: <br />109R-730WIL1 <br />SHEET <br />DESIGNER: <br />CUSTOMER RESIDENCE: <br />TEL. (714) 949-7874 <br />APN: 010-035-07 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 07 26 <br />RAHUL CHANDRA BHATT <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />COVER SHEET <br />SCOPE OF WORK GENERAL NOTES <br />PV-1.0 <br />VICINITY MAP <br />LTD: LR5-54HABB-400M <br />WITH STANDOFF TO FRAMING: SNR-DC-01249 [FLAT, FLUSH <br />MOUNT ( ROLLED COMP/ MEMBRANE/ FOAM) 1 LAG <br />OMNIBASE] <br />1707000-XX-Y <br />(MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE <br />#SSTAMPCS <br />#ESTAMPCS <br />ABBREVIATIONS <br />A AMPERE <br />AC ALTERNATING CURRENT <br />AFC ARC FAULT CIRCUIT INTERUPTER <br />AZIM AZIMUTH <br />COMP COMPOSITION <br />DC DIRECT CURRENT <br />(E)EXISTING <br />ESS ENERGY STORAGE SYSTEM <br />MSP MAIN SERVICE PANEL <br />(N) NEW <br />PRE-FAB PRE-FABRICATED <br />PSF POUNDS PER SQUARE FOOT <br />PV PHOTOVOLTAIC <br />RSD RAPID SHUTDOWN DEVICE <br />TL TRANSFORMERLESS <br />V VOLTS <br />W WATTS <br />SHEET INDEX <br />PAGE # DESCRIPTION <br />PV-1.0 COVER SHEET <br />PV-2.0 SITE PLAN <br />PV-2.1 ESS ELEVATION VIEW <br />PV-3.0 LAYOUT <br />PV-3.1 MOUNTING DETAIL <br />PV-4.0 ELECTRICAL <br />PV-4.1 ELECTRICAL CALCS <br />PV-4.2 BACKUP LOAD CALCS <br />PV-4.3 PANEL SCHEDULE <br />PV-5.0 SIGNAGE <br />NOTE: CEC 2022: 705.12(B)(3)(3): THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF BUSBAR. <br />MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION <br />INSTRUCTIONS. <br />SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A). <br />MODULES, ARE CLASS A FIRE RATED. <br />CONDUCTORS OUTSIDE OF THE ARRAY ARE LIMITED TO LESS THAN 30V IN 30 <br />SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE THE <br />ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS <br />ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH CEC 706.20 <br />AND EXCEPTION 1 CEC 706.20 (B). <br />CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER <br />706.15(D). <br />CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY <br />ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). <br />GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION <br />EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) <br />***The scope of the plans is for the <br />installation of the solar photovoltaic system <br />only and the approval is subject to <br />compliance with all applicable city and state <br />codes and regulations regarding <br />construction. The approval of the plans <br />does not constitute any certification of the <br />accuracy, completeness, or building permit <br />status of the existing buildings and <br />structures as shown. *** <br />Elect #20184329 <br /> <br />APPROVALS : <br />ELECT - M. Smith <br />1730 W Richland <br />Ave3/19/2025