My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 W Richland Ave - REV 1 - 20185604 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Richland Ave
>
1730 W Richland Ave
>
1730 W Richland Ave - REV 1 - 20185604 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:45:47 PM
Creation date
8/6/2025 9:56:56 AM
Metadata
Fields
Template:
Plan
Permit Number
20185604
Full Address
1730 W Richland Ave
Document Relationships
20185604 - Permit
(Permit - Plan)
Path:
\Building\Permits\R\Richland Ave\1730 W Richland Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: A 9/28/2024 <br />MONICA WILLIAMS <br />1730 W RICHLAND AVE, SANTA <br />ANA, CA, 92703 <br />PROJECT NUMBER: <br /> 109R-730WIL1 <br />SHEET <br />DESIGNER: <br />CUSTOMER RESIDENCE: <br />TEL. (714) 949-7874 <br />APN: 010-035-07 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 07 26 <br />RAHUL CHANDRA BHATT <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />PV-4.1 <br />ELECTRICAL CALCS <br />#ESTAMP <br />System Information <br />3.2 kW DC Photovoltaic System <br /> (8) LONGi Green Energy Technology Co Ltd: LR5-54HABB-400M, Tesla: Powerwall 3 1707000-xx-y <br />Allowable Backfeed <br />Allowable Backfeed = Main Panel Rating = 100A <br />Loads in Main Panel: 0A Loads + 70A Gateway Breaker = 70A ≤ 100A <br />Interconnection meets CEC 2022 705.12(B)(3)(3) requirements. <br />GATEWAY SYSTEM AC WIRE SIZING <br /> MAX AC OUTPUT CURRENT = 70 A <br /> ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(2)(A)] <br /> X (CONDUIT FILL)[TABLE 310.15(B)(3)(A)] X (CONDUCTOR <br />AMPACITY)[TABLE 310.15(B)(16)] = <br />0.91 X 1 X 95A = 86.45A <br /> TERMINAL RATING[110.14(C)] = <br /> 4 AWG, 75°C RATED = 85A <br />85A < 86.45A → TERMINAL RATING GOVERNS CONDUCTOR SIZING <br /> 70A ≤ 85A → 4 AWG AMPACITY OK <br /> THEREFORE 4 AWG IS SUFFICIENT. <br />Inverter Overcurrent Protection <br />(Inverter Max Current) x (Continuous Load) = <br />48 A x 1.25 = 60 A → 60 A Overcurrent Protection Per Manufacturer <br />DC Wire Sizing <br />Max Circuit Current = (Module Isc) x (High Irradiance)[690.8(A)(1)] x (Continuous Load)[690.8(B)(1)]= <br />13.72A x 1.56 = 21.4A <br />Adjusted Conductor Ampacity = (High Temp)[Table 310.15(B)(1)] x (Conduit Fill)[Table 310.15(C)(1)] x (Conductor Ampacity)[Table 310.16] = <br />0.91 x 0.8 x 40A = 29.12A <br />Terminal Rating[110.14(C)] = <br />10 AWG, Rated = 35A <br />29.12A < 35A → Terminal rating governs conductor sizing. <br />21.4A < 35A → 10 AWG Ampacity OK <br />Therefore 10 AWG is sufficient. <br />AC Wire Sizing <br />Max AC Output Current = (Max Inverter Output) x (Continuous Load)[210.19(A)(1)] = <br />48 A x 1.25 = 60 A <br />Adjusted Conductor Ampacity = (High Temp)[Table 310.15(B)(1)] x (Conduit Fill)[Table 310.15(C)(1)] x (Conductor Ampacity)[Table 310.16] = <br />0.91 x 1 x 75A = 68.25A <br />Terminal Rating[110.14(C)] = <br />6 AWG, Rated = 65A <br />65A < 68.25A → Terminal rating governs conductor sizing. <br />60A < 65A → 6 AWG Ampacity OK <br />Therefore 6 AWG is sufficient. <br />System Characteristics <br />Max Open Circuit Voltage = [((Temp Coef VOC) x (VOC)) / 100] x [Low Temp - STC Temp] + VOC x (# Modules / String) = <br />[(-0.26 %/°C x 37.05 V) / 100] x [2 °C - 25 °C] + 37.05 V x 4 = 159 V <br />Short Circuit Current = 1.25 x (Module Isc) x (# Strings) <br />1.25 x 13.72 A x 2 = 34.3A <br />1730 W Richland <br />Ave3/19/2025
The URL can be used to link to this page
Your browser does not support the video tag.