My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2060 N Tustin Ave- need V2 & V3 - 101116106 & 20180500 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tustin Ave
>
2060 N Tustin Ave
>
2060 N Tustin Ave- need V2 & V3 - 101116106 & 20180500 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:46:42 PM
Creation date
8/6/2025 10:09:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20180500
101116106
Full Address
2060 N Tustin Ave
Document Relationships
101116106 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\2060 N Tustin Ave
20180500 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\2060 N Tustin Ave
Text box
ID:
1
Creator:
COSA-PRIVATE\WRIDHUAN
Created:
8/6/2025 10:09 AM
Modified:
8/6/2025 10:08 AM
Text:
https://link.enphase.com/module-compatibility
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. <br />(2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per <br />branch in your area. <br />IQ7 and IQ7+ Microinverters <br />INPUT DATA (DC)UNITS IQ7-60-2-US IQ7PLUS-72-2-US <br />Commonly used module pairings1 W 235–350 235–440 <br />Module compatibility 60-cell/120 half-cell PV modules only 60-cell/120-half-cell and 72-cell/144-half-cell PV <br />modules <br />MPPT voltage range V 27–37 27–45 <br />Operating range V 16–48 16–60 <br />Min./max. start voltage V 22/48 22/60 <br />Max. input DC voltage V 50 60 <br />Max. continuous input DC current A 10 12 <br />Max. input DC short-circuit current A 25 <br />Max. module Isc A 20 <br />Overvoltage class DC port II <br />DC port back-feed current mA 0 <br />PV array configuration 1 × 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20 A <br />per branch circuit <br />OUTPUT DATA (AC)UNITS IQ7-60-2-US IQ7PLUS-72-2-US <br />Peak output power VA 250 295 <br />Max. continuous output power VA 240 290 <br />Nominal (L-L) voltage/range2 V 240/211–264, 208/183-229 <br />Max. continuous output current A 1.0 (240 V)/1.15 (208 V)1.21 (240 V)/1.39 (208 V) <br />Nominal frequency Hz 60 <br />Extended frequency range Hz 49–68 <br />AC short circuit fault current over <br />three cycles Arms 5.8 <br />Max. units per 20 A (L-L) branch circuit3 16/13 13/11 <br />Total harmonic distortion %<5 <br />Overvoltage class AC port III <br />AC port back-feed current mA 18 <br />Power factor setting 1.0 <br />Grid-tied power factor (adjustable)0.85 leading ... 0.85 lagging <br />Peak efficiency %97.6 (240 V)97.5 (240 V)/97.3 (208 V) <br />CEC weighted efficiency %97 <br />Nighttime power consumption mW 60 <br />MECHANICAL DATA <br />Ambient temperature range -40°C to 65°C (-40°F to 149°F) <br />Relative humidity range 4% to 100% (condensing) <br />DC connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) <br />Dimensions (H × W × D)212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2") without bracket <br />Weight 1.08 kg (2.38 lbs) <br />Cooling Natural convection—no fans <br />Approved for wet locations Yes <br />Pollution degree PD3 <br />Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure <br />Environ. category/UV exposure rating NEMA Type 6/outdoor <br />COMPLIANCE <br />Certifications <br />CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), HEI Rule 14H SRD 2.0, FCC Part 15 Class B, ICES-0003 Class B, CAN/ <br />CSA-C22.2 NO. 107.1-01 <br />This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2015 <br />Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to the manufacturer’s instructions. <br />IQ7-IQ7Plus-DS-02-EN-US-2023-04-14 <br />2060 N Tustin Ave - 101116106 & <br />20180500 <br />10/4/2023
The URL can be used to link to this page
Your browser does not support the video tag.