Laserfiche WebLink
PAGE <br />REV: I 2/14/2025 <br />MIGUEL TOLEDO <br />2140 S BROADWAY, SANTA ANA, <br />CA, 92707 <br />PROJECT NUMBER: <br /> 109R-140TOLE <br />SHEET <br />DESIGNER: <br />AL AMEEN V H <br />CUSTOMER RESIDENCE: <br />TEL. (714) 272-5451 <br />APN: 015-082-22 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024.02.28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (2) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 PV Load Center Output (2) 3 AWG <br />THHN/THWN-2 <br />(1) 3 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT <br />E EXISTING <br />EXISTING 100A <br />MAIN BREAKER <br />END FED <br />EXISTING 125A <br />MAIN PANEL <br />125A BUS <br />(N) LOCKABLE <br />BLADE TYPE <br />AC DISCONNECT <br />SQUARE D <br />DU222RB <br />3R, 60A , 2P <br />120/240VAC <br />3 <br />A <br />A <br />EXISTING 100A SUB PANEL <br />WITH 100A MAIN BREAKER <br />(E) LOADS <br />E <br />TESLA <br />POWERWALL 3 1707000-XX-Y <br />TESLA: POWERWALL <br />3 1707000-XX-Y <br />11500 WATT <br />INVERTER <br />LOAD RATED DC <br />DISCONNECT WITH <br />AFCI RAPID <br />SHUTDOWN COMPLIANT, <br />POWER CONTROL SYSTEM <br />3 <br />J-BOX <br />LONGi Green Energy Technology Co Ltd <br />LR5-54HABB-395M <br />STRING 1 OF 7 MODULES <br />3 MODULE LEVEL <br />RAPID SHUTDOWN DEVICES <br />12 <br /> POINT OF INTERCONNECTION:705.13, GATEWAY FEEDER <br />BREAKER AT OPPOSITE END OF BUSBAR <br /> METER NUMBER: 222013-165258 <br /> EQUIPMENT CHARACTERISTICS <br />INCLUDED IN SPEC SHEETS <br /> NOTE: TOTAL PV BACKFEED(E+N) <br />= 80A USED FOR INTERCONNECTION CALCULATIONS <br />J-BOX <br />(15) HANWHA Q-CELLS: <br />Q.PRO-G4 265 MODULES <br />AND MICRO-INVERTER PAIRS <br />(15) ENPHASE ENERGY: <br />M215-60-2LL-S2X-IG <br />EE <br />E <br /> 20A OCPD <br />M <br />Existing <br />Production Meter <br />E <br />Existing <br />Knife Disconnect 30A Rated <br />E <br />Existing <br />Combiner Panel XA Rated <br />E <br />E <br />(N) TESLA <br />REMOTE METER <br />SOLAR CURRENT <br />TRANSFORMERS <br />M <br />TESLA <br />BACKUP <br />SWITCH <br />NEW 200A <br />PV LOAD CENTER <br />(N) (1) - 60A (ESS+PV)BREAKER <br />(E) 20A PV BREAKER <br />4100AOCPD <br />100AOCPD <br />UL 9540 <br />FACTORY <br />WIRING <br />ASSEMBLY <br />(1 ) TESLA <br />POWERWALL 3 <br />EXPANSION PACK 1807000-XX-Y <br />PV-4.0 <br />ELECTRICAL <br />#ESTAMP <br />MODULE CHARACTERISTICS <br />LONGI GREEN ENERGY <br />TECHNOLOGY CO LTD: <br />LR5-54HABB-395M <br />395 W <br />OPEN CIRCUIT VOLTAGE 36.81 V <br />MAX POWER VOLTAGE 30.7 V <br />SHORT CIRCUIT CURRENT 14.79 A <br />GENERAL NOTES: <br />• CITY REQUIRES TWO SOURCES OF GROUND - UFER, <br />TWO GROUNDS RODS OR COLD WATER GAS BOND <br />POWER CONTROL SYSTEM (PCS): <br /> • A PCS IS INSTALLED IN ACCORDANCE WITH NEC 705.13 <br /> • THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT <br />CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE <br />RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER <br />PRODUCTION SOURCES <br /> • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE <br />SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL <br />COMPLY WITH ARTICLE 705.12. <br /> • ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED <br />PERSONS IN ACCORDANCE WITH 240.6(C). <br /> • ENERGY STORAGE SYSTEM: TESLA: POWERWALL 3 1707000-XX-Y <br /> • ENABLE PCS <br /> SETPOINTS: <br /> - 100A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED <br />PANEL <br /> - 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY <br />(120% COMPLIANT) <br />INSTALL THE BACKED UP LOAD CONDUCTORS AND THE <br /> GATEWAY BREAKER CONDUCTORS IN TWO SEPARATE CONDUITS. <br />I <br />2140 S Broadway <br />3/21/2025