My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2140 S Broadway - REV 1- 20185638 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
2140 S Broadway
>
2140 S Broadway - REV 1- 20185638 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:47:09 PM
Creation date
8/6/2025 10:18:48 AM
Metadata
Fields
Template:
Plan
Permit Number
20185638
Full Address
2140 S Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BACKUP LOADS <br />LOAD BREAKER RATING <br />(AMPS)LABEL DEMAND LOAD(VA) <br />1 100A-2P SUB PANEL 19200 W <br />2 30A-2P DRYER 5760 W <br />BACKUP LOAD CALCS <br />PV-4.2 <br />BACKUP LOAD CALCS <br />#ESTAMP <br />PAGE <br />REV: A 9/24/2024 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />MIGUEL TOLEDO <br />2140 S BROADWAY, SANTA ANA, <br />CA, 92707 <br />PROJECT NUMBER: <br /> 109R-140TOLE <br />SHEET <br />DESIGNER: <br />AL AMEEN V H <br />CUSTOMER RESIDENCE: <br />TEL. (714) 272-5451 <br />APN: 015-082-22 <br />GILBERT CORREIA, C10, C46 <br />CA CL #750184 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE PANEL. <br />BACKED UP LOADS CALCULATION: <br />(5760 VA)/ 240V = 24 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. <br />THE MAXIMUM CURRENT FOR ALL SMALL APPLIANCES LOADS IS 24A. <br />(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) = <br />24 A X 1.25 = 30A <br />BACKED UP LOADS PANEL BREAKER = 70A <br />30 A < 70A. <br />THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. <br />AC WIRE SIZING FOR BACKED UP LOADS PANEL: <br />MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />30 A X 1.25 = 38A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X <br />(CONDUCTOR AMPACITY)[TABLE 310.16] = <br />0.91 X 1 X 55A = 50.05A <br />TERMINAL RATING[110.14(C)] = <br />8 AWG, 75°C RATED = 50A <br />50A < 50.05A TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />38A ≤ 50A 8 AWG AMPACITY OK <br />THEREFORE 8 AWG IS SUFFICIENT. <br /> <br />AC WIRE SIZING FOR BACKED UP LOADS PANEL: <br />MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />12.5 A X 1.25 = 15.625A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X <br />(CONDUCTOR AMPACITY)[TABLE 310.16] = <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />12 AWG, 75°C RATED = 35A <br />35A < 36.4A TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />15.625A < 35A 12 AWG AMPACITY OK <br />THEREFORE 12 AWG IS SUFFICIENT. <br /> <br /> <br />2140 S Broadway <br />3/21/2025