My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2614 A Everglade St - 101118489 & 20182273 - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Everglade St
>
2614 S Everglade St
>
2614 A Everglade St - 101118489 & 20182273 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:47:40 PM
Creation date
8/6/2025 10:20:17 AM
Metadata
Fields
Template:
Plan
Permit Number
20182273
101118489
Full Address
2614 S Everglade St
Document Relationships
101118489 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Everglade St\2614 S Everglade St
20182273 - Permit
(Permit - Plan)
Path:
\Building\Permits\E\Everglade St\2614 S Everglade St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(N) 60ASINGLE VISIBLYOPEN & LOCKABLE,AC DISCONNECT240V NEMA-3RGEnphase IQ Gateway(N) 125A ENPHASE IQCOMBINER 4/4C NEMA-3RX-IQ-AM1-240-4/4C[CRD-PCS NEM) 240VREVENUE-GRADEPRODUCTION METERINGFACTORY INSTALLEDenphaseENERGY(N)20A/2P(N)15A/2PEACH WITH ANENPHASE IQ8M-72-2-USMICROINVERTERAC(N)J-BOXG1 BRANCH OFMODULES11SOURCE CIRCUIT #1Isc = 14.85 AENPHASE Q CABLE2-#121-#6 GRNDOPEN AIR(N)20A/2PEACH WITH ANENPHASE IQ8M-72-2-USMICROINVERTERAC(N)J-BOXG1 BRANCH OFMODULES10SOURCE CIRCUIT #2Isc = 13.5 ATHWN-23-#101-#8 GRND3/4" EMT CONDUITTHWN-23-#81-#8 GRND3/4" EMT CONDUITMAIN SERVICE PANEL, 240VGROUNDING ELECTRODE &AUXILIARY GROUNDINGELECTRODE AS NEEDED PERCEC 690.47 (6 FEET APART)LLLLGND <br />N LOADS (E) A TOP FEDMETER #222013-028556 (N)200200A/2P(N)(N)40A/2PE7SHEET NUMBER:SEMPER SOLARIS <br />1805 JOHN TOWERS AVE <br />EL CAJON, CA 92020 <br />C-10 LIC # 978152 <br />Lic. Holder Digitally Stamped <br />PROJECT FOR:PROPOSEDDRAWN BY:DATE:(DC) kW:PROJECT #:John AlmondEVOLUTION11/14/2023859428.400KAREN N FLORES & ORLANDO MACIAS <br />SANTA ANA CA 92704 <br />2614 S EVERGLADE ST <br />(714) 824-1142 <br />APN - 41406114 <br />SOLAR PHOTOVOLTAIC <br />SYSTEM SIZE: <br />8.400 kW DC PV <br />MAIN LINE: 619-357-4142 UTILITY COMPANY:MSP VOLTAGE:MSP GROUND:SERV. TYPE:SERVICE INFOSCE120/240UNDERGROUND(N) ROD2% Avg. 1"MINASHRAE AMBIENT TEMPERATURE SPECS° C° CHigh TempEXTREMEDISTANCEABOVE ROOFNO TEMP ADDERPER 310.15(B)(2)312BUSBARMAINBREAKERMAXPV OCP( 200A x 1.2 ) - 200A = 40ACEC705.12(B)(3)(2)INTERCONNECTION METHOD PER 705.12(B)(3)(2):WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHERANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THATCONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUTCIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTINGTHE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR.MSP IS UPGRADED TO 200A/200A NCF.(N)BRNSURGE SURGE PROTECTOR - COMPATIBLE WITH EATON, GE,SIEMENS, CROUSE HINDS PANELBOARDS2614 S EvergladeSt3/18/2024