Laserfiche WebLink
Service Voltage <br />240 <br />Section 220.82 Dwelling Unit <br />Part #1 - Section 220.82(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: <br />Amps Box A (VA) <br />27.15 6516 <br />Part #2 - Section 220.82(B)(3)a, b, c, d - Appliances and Dedicated Circuits: <br />Size in VA Size in VA <br />1500 <br />1500 <br />1500 <br />1000 <br />600 <br />1000 <br />1600 <br />Amps Box B (VA) <br />36.25 8700 <br />Total VA from Parts #1 and #2 combined:Box A + Box B =15216 <br />Total VA 15216 <br />First 10000 VA @ 100%10000 Remaining VA @ 40% <br />Remaining VA =5216 5216 x 40% =2086.4 VA <br />Adding First 10000 VA, if possible 10000 VA <br />Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:12086.4 VA <br />Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:50.36 Amps <br />Part #3 - Section 220.82(C) Heating and A/C loads: <br />*Combine the larger loads of either the Heating or the A/C loads togther <br />100% of all the Heating or A/C loads in VA:0 VA <br />100% of all the Heating or A/C loads in Amps:0.00 A <br />VA Volts Amps <br />Parts #1 & #2 12086.4 240 50.36 <br />Part #3 0 240 0.00 <br />Total VA for all Parts:12,086 <br />Totals Service/Feeder Load 50.36 <br />Dedicated circuit Dedicated circuit <br />Article 220 - Dedicated Backup Panel Calculation Job Code <br />526 S Ross St <br /> Santa Ana, CA 92701 <br />109R-526VEL1 <br />Building Square Footage VA (watts)Amps <br />House 2172.00 6516 27.15 <br />Total for Part #1: <br />Laundry <br />Appliance Circuit - 1 <br />Appliance Circuit - 2 <br />Dishwasher <br />Disposal <br />Refrigerator <br />Microwave <br />Totals for Part #2: <br />Totals from all Parts <br />HISTORIC-526 S <br />Ross St3/21/2025