My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
526 S Ross St - 101122337 & 20185008 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
526 S Ross St
>
526 S Ross St - 101122337 & 20185008 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 1:48:10 PM
Creation date
8/6/2025 10:26:03 AM
Metadata
Fields
Template:
Plan
Permit Number
20185008
101122337
Full Address
526 S Ross St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BACKUP LOADS <br />LOAD BREAKER RATING <br />(AMPS)LABEL DEMAND <br />LOAD <br />1 15A-1P GAR LITES 1500 VA <br />2 15A-1P LIGHTING/RECEPTACLES 1500 VA <br />3 20A-1P GAR OUTSIDE 1500 VA <br />4 20A-1P PLUGS 1500 VA <br />5 20A-1P MASTER BATH 1500 VA <br />6 20A-1P DISH WASHER 1500 VA <br />7 20A-1P DISPOSAL 1500 VA <br />8 20A-1P GAR PLUGS 1500 VA <br />9 20A-1P LIGHTS 1500 VA <br />10 20A-1P LIGHTING/RECEPTACLES 1500 VA <br />11 50A-2P SUB PANEL 9600 VA <br />PAGE <br />REV: A 1/16/2025 <br />RUBEN VELASCO <br />526 S ROSS ST, SANTA ANA, CA, <br />92701 <br />PROJECT NUMBER: <br /> 109R-526VEL1 <br />SHEET <br />DESIGNER: <br />CHIPPY PRINCE <br />CUSTOMER RESIDENCE: <br />TEL. 7143818044 <br />APN: 010-134-15 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />#ESTAMP <br />PV-4.3 <br />ALL BACKED UP LOADS ABOVE IN THE BACKED UP LOADS PANEL ARE RELOCATED FROM THE MAIN SERVICE <br />PANEL. <br />BACKED UP LOADS CALCULATION: <br />(9600VA)/ 240V = 40 A PER CEC 2022 ARTICLE 690.10 OR NEC 2020 ARTICLE 710.15. <br />THE MAXIMUM CURRENT FOR ALL LARGE APPLIANCES LOADS IS 40 A. <br />(MAX LOADS OUTPUT) X (CONTINUOUS LOADS) = <br />40 A X 1.25 = 50A <br />GATEWAY FEEDER BREAKER = 70A <br />50 A < 70A. <br />THEREFORE, THE AMPERAGE OF THE BACKED UP LOADS IS LESS THAN THAT OF THE OCPD. <br />AC WIRE SIZING FOR BACKUP LOADS PANEL <br />MAX AC OUTPUT CURRENT = (MAX LOADS OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />40 A X 1.25 = 50A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X <br />(CONDUCTOR AMPACITY)[TABLE 310.16] = <br />0.91 X .5X 55A = 25.02A <br />TERMINAL RATING[110.14(C)] = <br />8 AWG, 75°C RATED =50A <br />25.02A < 50A TERMINAL RATING GOVERNS CONDUCTOR SIZING <br />40A ≤ 50A 8 AWG AMPACITY OK <br />THEREFORE 8 AWG IS SUFFICIENT. <br /> <br /> <br />BACKUP LOAD CALCS <br />BACKUP LOAD <br />CALCS <br />HISTORIC-526 S <br />Ross St3/21/2025