Laserfiche WebLink
.--SANTA <br />NA <br />PI-$]NC <br />&BUIDIIC <br />tcilcI <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-'19) <br />Santa Ana, CA927Oz <br />(714) 647-s800 <br />www.santa -ana.org <br />RESIDENTIAL <br />PHOTOVOLTA!C <br />CHECKLIST <br />sol-01 cBC 2013 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall fill in the address of the project, contractor's <br />licensing information and answer queslions 1 -10 below. Complete and sign the certiflcation section**lf answering NO to any of the questions, plan check shall be required.*' <br />Project Address:2'103 North Ross Street Santa Ana, CA 92706 <br />Contractor Gompany Name:VERENGO, INC. <br />contractor License Number' 935263 <br />Are the following applicable to the proposed project? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 3 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to l0" maximum between <br />the underside of modules and the surface of the roof? <br />Witl the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV system layout provide a three-foot wide clear access pathway per the <br />latest edition of "Guideline for Fire Safety Elements of Solar Photovoltaic Systems" <br />by OCFA? (Guideline available on the OCFA website: htto://wiarw.ocfa.orq) <br />Do the plans show a maximum horizontal anchor spacing of6 feet? <br />Do the plans show a minimum ol 2-112 inch lag screw embedment into roof rafters? <br />Are ALL the structural pages of the plans WET stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />I certify under penalty of perj ury under the laws of the State of Ca ea s true <br />print name: MICHAEL KAISERNTAN Signature <br />Phone Number: 3'10-953-9293 <br />, refunds@verengosolar.comEma Address: <br />YES NOgtr <br />Eltr <br />Eltr <br />2 <br />3 <br />4 <br />5 <br />6 <br />sltr <br />rylu(s <br />Mn7 <br />8 gEl <br />e gtr <br />10 EE <br />Rev:211712015 <br />Date. MAY 15. 2018 <br />1