Laserfiche WebLink
RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />soL-01 cBc 2013 <br />Solar Photovoltaic (PV) Checklist tor Detached STNGLE FAMTLY RESIDENCES Onty <br />lnstructions: The licensed contractor of record shall complete all sections, answer lhe ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum'11" x 17" size. lf answerino NOt o anv of the questions. Dlan check shall be required. <br />Proiect Address:1O3O S. SHERWOOD LANE, SANTA ANA, CA 92706 <br />Contractor Company Name:SOUTHWEST SUN SOLAR, INC <br />contractor License Number: 1004667 <br />2 <br />YES NOatr <br />Ettr <br />Etr <br />Etr <br />Etr <br />Etr <br />atr <br />Etr <br />Ettr <br />Etr <br />Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the Califomia Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one rooling layer with no <br />overlays? <br />Will the PV array be flush mounted to the exisling roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2, minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on lhe plans? <br />Are ALL tha structural pages of the plans WET stamped and signed by a California <br />licensed professional engineer? (including project specific site plan, PV layout, <br />3 <br />6 <br />7 <br />I <br />I <br />10. <br />anchorage spacing, anchorage details and manufacturefs PV supp ort information <br />I certify under penalty of periury under the laws of the Slate of California above is true: <br />print Name: TRANG CONG PHAM Signature <br />phone Number: 714 582 3909 Dale:c <br />Emait Address: PERIV lT@SOUTHWESTSUNSOLAR.COM <br />Revi 8/'1 7/201 5 <br />at <br />,--SANTA <br />NA-"ffiT <br />Planning & Building Agency <br />Building Satety Division <br />20 Civic Cenler Plaza <br />P.O. Box '1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-s8oo <br />www.santa.ana.org <br />4. <br />5.