My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
610 S BroadwayV2 - 101110702 & 20176387 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
610 S Broadway
>
610 S BroadwayV2 - 101110702 & 20176387 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 10:19:21 AM
Creation date
8/7/2025 10:17:40 AM
Metadata
Fields
Template:
Plan
Permit Number
20176387
101110702
Full Address
610 S Broadway
Document Relationships
101110702 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Broadway\610 S Broadway
20176387 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Broadway\610 S Broadway
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET: <br />DRAFTER <br />SIGNATURE <br />PROJECT ADDRESS: <br />REVISION # <br />DATE: <br />05/12/2022 <br />DRAWING <br />TYPE <br />PENGUIN HOME SOLUTIONS IBARRA, BELEN <br />610 S BROADWAY, <br />SANTA ANA, CA 92701 <br />(000) 000-0000 <br />21860 VAN BUREN BLVD, BLDG 11, SUITE 101, <br />RIVERSIDE, CA 92518 <br />(888) 488 8001 <br />LICENSE#: C-10 1033658 <br />PV-5 <br />SINGLE LINE DIAGRAM <br />NOTES: <br />· CONDUTORS ON ROOF MUST BE SUNLIGHT RESISTANT, 90°C RATED AND SUITABLE FOR WET LOCATIONS. <br />· SEE RACKING SPEC SHEETS FOR RACKING EQUIPMENT GROUNDING METHOD. <br />· ALL GROUNDING CONDUCTORS MUST BE PROTECTED FROM DAMAGE IF NOT INSTALLED IN CONDUIT. <br />· ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR <br /> SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF. <br />· ALL DEVICES USED FOR BONDING FRAMES OF MODULES OR OTHER EQUIPMENT TO THE GROUNDING SYSTEM <br /> MUST BE LISTED AND IDENTIFIED FOR THE PURPOSE. <br />· SOLAREDGE OPTIMIZERS ARE TO BE BONDED TO RACKING BY USING EITHER AN OPTIMIZER ATTACHMENT KIT <br /> OR A SOLAREDGE GROUNDING PLATE. (SEE SPEC SHEETS). <br />· ALL CONDUCTORS SHALL BE COPPER. <br />· ALL ROOFTOP RACEWAYS SHALL BE INSTALLED A>=7/8" ABOVE ROOF. <br />· INTEGRATED GROUNDING IN ACCORDANCE WITH THE RACKING MANUFACTURER INSTALLATION INSTRUCTIONS <br />CAN ONLY BE USED FOR BONDING THE MODULES TO THE RACKING WHERE THE SPECIFIC MODULE CATALOG <br />NUMBER HAS BEEN TESTED TO UL2703 STANDARDS BY AN ACCREDITED NRTL. WHERE THE MODULE CATALOG <br />NUMBER IS NOT PART OF THE RACKING SYSTEM APPROVED MODULE LIST, BOND ALL MODULES AND ALL RAILS <br />USING A UL2703 LISTED LAY-IN LUG SUCH AS ILSCO GBL-4DBT. <br />5.135 kW (DC) SOLAR ARRAY: <br />(13) CANADIAN SOLAR CS3N-395MS (395W) WITH <br />(13) SOLAREDGE POWER OPTIMIZERS: P400 WITH <br />(1) SOLAREDGE WAVE 3.8KW INVERTER: SE3800H-US-RGM <br />(1) STRING OF (13) MODULES <br />UTILITY <br />METER <br />100AMP 2-POLE <br />MAIN BREAKER <br />(N)20AMP 2-POLE <br />PV BREAKER <br />N <br />G <br />3/4" EMT OR EQUIVALENT (ON ROOF, UNDER EAVES) <br />(2) #10 AWG THWN-2 CONDUCTORS <br />(1) #8 AWG THWN-2 GROUND <br />CONDUCTORS EXPOSED TO FREE AIR <br />(2) #10 AWG PV-WIRE 600V/RHW-2 <br />(1) #6 AWG BARE COPPER GROUND <br />WIRE IN CONDUIT CAN BE #8 AWG THWN-2 <br />3/4" EMT OR EQUIVALENT <br />(2) #8 AWG THWN-2 CONDUCTORS <br />(1) #8 AWG THWN-2 NEUTRAL <br />(1) #8 AWG THWN-2 GROUND <br />AC DISCONNECT <br />(WITHIN 10' OF MSP) <br />NEMA <br />TYPE 3R <br />UL LISTED <br />JUNCTION <br />BOX <br />AR-01 <br />(13) CANADIAN SOLAR CS3N-395MS <br />(395W) IN (1) STRING OF (13) MODULES <br />AT (20°) PITCH AND (180°) ORIENTATION <br />120/240 VAC SERVICE <br />EXISTING 100A MAIN SERVICE <br />PANEL W/ 100A MAIN <br />BREAKER ON CENTER FED. <br />INSTALL NEW <br />20A 2-POLE PV BREAKER AT <br />END OF BUS BAR. <br />AC OUT <br />DC IN <br />NOTE: INTEGRATED DC DISCONNECT IS <br />INSTALLED WITH RAPID SHUTDOWN <br />DEVICE BY MANUFACTURER IN <br />COMPLIANCE WITH NEC 690.12. <br />(13) SOLAREDGE: P400 <br />DC OPTIMIZERS <br />NEW SQUARE D <br />DU221RB <br />30A, 240V, 2P <br />NON-FUSED, <br />NEMA 3R ENCLOSURE <br />(OR EQUIV.) <br />SOLAREDGE TECHNOLOGIES: <br />SE3800H-US-RGM (240V) GRID TIED <br />2-POLE 3800 WATTS INVERTER <br />AC MAX OUTPUT CURRENT OF 16A <br />MAX OUTPUT CURRENT 16.89A <br />1.56 <br />MULTIPLE CONDUCTOR FACTOR 1.0 <br />TEMP CORRECTION FACTOR 0.71 <br />AMPACITY OF #10 WIRE (THWN-2 @ 90 °C) 40A <br />MAXIMUM AMPACITY <br />16.89A * 1.56 = 26.34A < 40A <br />CONTINUOUS DUTY AND HIGH <br />IRIDESCENCE FACTOR <br />DC AMPACITY CALCULATION <br />40A * 1.0 * 0.71 = 28.4A > 16.89A <br />ADJUSTED AMPACITY <br />INVERTER OUTPUT CURRENT 16A <br />CONTINUOUS DUTY FACTOR 1.25 <br />MULTIPLE CONDUCTOR FACTOR 1.0 <br />TEMP CORRECTION FACTOR 0.88 <br />AMPACITY OF #8 WIRE (USE 75°)50A <br />MAXIMUM AMPACITY <br />16A * 1.25 = 20.0A < 50A <br />ADJUSTED AMPACITY <br />INVERTER OCPD RATING <br />AC AMPACITY CALCULATION FOR 3.8KW INVERTER <br />50A * 0.88 = 44.0A > 16A <br />20A <br />(E) UFER <br />#4 AWG CU GEC <br />610 S Broadway <br />06/09/22
The URL can be used to link to this page
Your browser does not support the video tag.