Laserfiche WebLink
STRUCTURAL NOTES <br />NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THESE STANDARD <br />STRUCTURAL NOTES.DETAILS NOTED AS "TYPICAL"SHALL BE USED WHENEVER APPLICABLE. <br />REFER TO SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE NOTES OR DRAWINGS. <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE <br />STARTING WORK, AND THE ENGINEER/ARCHITECT SHALL BE IMMEDIATELY NOTIFIED, IN WRITING, <br />OF ANY DISCREPANCIES. IN NO CASE SHALL DIMENSIONS BE SCALED FROM PLANS, SECTIONS, <br />OR DETAILS ON THE STRUCTURAL DRAWINGS. <br />ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE STRUCTURAL DRAWINGS <br />AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF, AND RESOLVED WITH, THE <br />ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. <br />WHERE A CONSTRUCTION DETAIL IS NOT SPECIFICALLY SHOWN OR NOTED, THE DETAIL SHALL BE <br />THE SAME AS FOR OTHER SIMILAR WORK. <br />THE CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN THE AREA TO BE <br />EXCAVATED, BEFORE BEGINNING EXCAVATION. <br />NO PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL BE PLACED IN OR THRU SLABS, BEAMS, OR <br />WALLS, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC. EXCEPT AS <br />INDICATED ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR <br />INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. <br />THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS <br />DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS <br />AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL <br />WORKING HOURS. <br />RETAIN A CALIFORNIA REGISTERED CIVIL ENGINEER TO DESIGN ALL TEMPORARY BRACING, <br />SHORING, AND SUPPORT REQUIRED DURING CONSTRUCTION. <br />INCLUDE ENGINEERING FEES, ENGINEERING DESIGN TIME AND BUILDING DEPARTMENT APPROVAL <br />TIME IN THE COST OF PROPOSED MATERIAL ALTERNATES. CONTACT ENGINEER FOR FEE AMOUNT. <br />SUBMIT MATERIAL ALTERNATE FOR REVIEW BEFORE CONSTRUCTION. <br />ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE 2019 CBC. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />8. <br />9. <br />10. <br />7. <br />GENERAL <br />11. IF STRUCTURAL OBSERVATIONS ARE REQUIRED, PROVIDE 72 HOURS NOTICE PRIOR TO OBSERVATION. <br />STRUCTURAL STEEL <br />ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE CBC CHAPTER 22, <br />FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL BUILDINGS. <br />WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. OTHER ROLLED SHAPES AND PLATES SHALL <br />CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE. HSS SHALL CONFORM TO ASTM A500, <br />GRADE-B. PIPES SHALL CONFORM TO ASTM A53, GRADE-B. IDENTIFICATION PROCEDURES SHALL <br />CONFORM TO ASTM A6. <br />MACHINE BOLTS SHALL BE GRADE-A CONFORMING TO ASTM A307. ANCHOR BOLTS SHALL BE ASTM F1554, <br />GRADE 36. NUTS FOR MACHINE BOLTS AND ANCHOR BOLTS SHALL CONFORM TO ASTM A563, HEX <br />GRADE-A. THREADED RODS SHALL CONFORM TO ASTM A36. THREADED AND NUTTED ANCHOR BOLTS <br />SHALL BE ASTM F1554, GRADE 36. ROUND WASHERS SHALL CONFORM TO ASTM F436. <br />HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325. NUTS FOR HEIGHT STRENGTH BOLTS <br />SHALL BE HEAVY HEX, GRADE-C, CONFORMING TO ASTM A563. INSTALLATION OF HIGH STRENGTH <br />BOLTS SHALL BE INSPECTED AS REQUIRED BY "SPECIFICATION FOR STRUCTURAL JOINTS USING <br />ASTM A325 OR A 490 BOLTS" (JUNE 2004). <br />ALL BOLT HOLES SHALL BE 1/16" LARGER THAN THE BOLT, UNLESS NOTED OTHERWISE. <br />HEADED STUDS EMBEDDED IN CONCRETE SHALL CONFORM TO ASTM A108. <br />NON-SHRINK GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 7000 SPI PER <br />ASTM C109. NON-SHRINK GROUT SHALL BE INSTALLED IMMEDIATELY AFTER COLUMN IS PLUMBED. <br />CONTRACTOR SHALL NOT LOAD COLUMN ANCHOR BOLTS BEFORE PLACEMENT OF NON-SHRINK GROUT <br />WITHOUT TAKING MEASURES TO PREVENT BUCKLING OF ANCHOR BOLTS UNDER CONSTRUCTION LOAD. <br />WELDING SHALL CONFORM TO THE LATEST EDITION OF AWS D1.1 AND SHALL USE EITHER THE <br />SHIELDED OR FLUX CORE METHODS. ELECTRODES USED SHALL BE E70XX, E71-T8 OR E70-T6. <br />WELDERS SHALL BE CERTIFIED. <br />WELDS IDENTIFIED AS REQUIRING CONTINUOUS OR PERIODIC SPECIAL INSPECTION NEED NOT HAVE <br />CONTINUOUS SPECIAL INSPECTION WHEN THE WELDING IS DONE IN AN APPROVED FABRICATOR'S SHOP. <br />HOWEVER, THE APPROVED FABRICATOR MUST SUBMIT A CERTIFICATE OF COMPLIANCE IN ACCORDANCE <br />WITH CBC SECTION 1704.2. <br />ALL FULL PENETRATION GROOVE WELDS FOR MOMENT FRAME MEMBERS SHALL BE ULTRASONICALLY <br />INSPECTED BY AN APPROVED TESTING AGENCY AND SHALL CONFORM TO THE LATEST EDITION OF <br />AWS D1.1, SECTION 5 & 6. <br />ALL STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED AND ALL FIELD WELDS <br />FOR SUCH MEMBERS SHALL BE TOUCHED UP WITH GALVALOID. <br />STEEL FABRICATOR TO VERIFY ALL DIMENSIONS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. <br />STEEL FABRICATOR TO COORDINATE WITH MECHANICAL SUBCONTRACTOR FOR THE SIZE, LOCATION, <br />AND DIMENSIONS OF MECHANICAL UNITS AND OPENINGS. <br />ALL FABRICATION SHALL BE DONE IN A SHOP OF AN APPROVED FABRICATOR. STRUCTURAL STEEL <br />SHOP DRAWINGS SHALL BE SUBMITTED TO AND REVIEWED BY THE ENGINEER BEFORE FABRICATION. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />SPECIAL INSPECTION REQUIRED <br />SPECIAL INSPECTION <br />1.SPECIAL INSPECTION SHALL MEET THE REQUIREMENTS OF CBC SECTION 1704. <br />2.SPECIAL INSPECTORS SHALL: <br />A.BE UNDER THE SUPERVISION OF A CALIFORNIA REGISTERED CIVIL ENGINEER. <br />B.OBSERVE THE WORK ASSIGNED FOR CONFORMANCE WITH THE APPROVED DRAWINGS AND <br />SPECIFICATIONS. <br />C.FURNISH INSPECTION REPORTS TO THE ENGINEER AND BUILDING DEPARTMENT. DISCREPANCIES SHALL BE <br />BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN IF NOT <br />CORRECTED, TO THE ENGINEER AND BUILDING DEPARTMENT. <br />D.SUBMIT TO THE ENGINEER AND BUILDING DEPARTMENT A FINAL REPORT, SIGNED BY A CALIFORNIA <br />REGISTERED CIVIL ENGINEER, STATING THAT THE WORK WAS IN CONFORMANCE WITH THE APPROVED <br />DRAWINGS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CBC. <br />3.INSPECTION NOTES: <br />A.CONSTRUCTION INSPECTIONS LISTED ARE IN ADDITION TO THE CALLED INSPECTIONS REQUIRED BY CBC <br />SECTION 109,APPENDIX CHAPTER 1. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY A <br />BUILDING OFFICIAL. SPECIALLY INSPECTED WORK WHICH IS INSTALLED OR COVERED WITHOUT APPROVAL <br />OF THE BUILDING OFFICIAL IS SUBJECT TO REMOVAL OR EXPOSURE. <br />B.CONTINUOUS INSPECTION IS ALWAYS REQUIRED DURING PERFORMANCE OF THE WORK UNLESS <br />SPECIFICALLY NOTED. <br />C.SPECIAL INSPECTORS MUST BE CERTIFIED BY THE BUILDING DEPARTMENT TO PERFORM THE TYPES OF <br />INSPECTIONS SPECIFIED. <br />D.IT IS THE RESPONSIBILITY OF THE OWNER TO INFORM THE SPECIAL INSPECTOR OR INSPECTION AGENCY AT <br />LEAST ONE WORKING DAY BEFORE PERFORMING ANY WORK THAT REQUIRES SPECIAL INSPECTION. ALL <br />WORK PERFORMED WITHOUT REQUIRED SPECIAL INSPECTION IS SUBJECT TO REMOVAL. <br />1.ANCHORS, ANCHOR BOLTS, & DOWELS <br />A.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS (AND TESTING) OF EPOXIED DOWELS IN <br />CONCRETE AT (HOLDOWNS) (EXISTING FOOTINGS) (CONCRETE REPAIRS). <br />B.VERIFY MANUFACTURERS INSTALLATION REQUIREMENTS OF WEDGE AND SLEEVE ANCHORS (WHERE <br />INDICATED). <br />SCHED.SCHEDULEHDHOLD DOWNBOTTOMBTM. <br />DITTO (REPEAT) <br />EXST. (E) <br />EXP. <br />EXT. <br />EXPANSION <br />EXTERIOR <br />EXISTING <br />DP (D) <br />EL. <br />EQ. <br />ENG. <br />E.N. <br />EMBD. <br />ELEV. <br />ELEC. <br />EQPT. <br />DWG. <br />DWL. <br />EA. <br />E.J. <br />E.F. <br />ELEVATION <br />ENGINEER <br />EDGE NAIL/SCREWS <br />EMBED(MENT) <br />ELECTRICAL <br />EQUIPMENT <br />EQUAL <br />ELEVATOR <br />DEEP (DEPTH) <br />DRAWING(S) <br />EXPANSION JOINT <br />EACH FACE <br />DOWEL(S) <br />EACHEACH <br />EACH <br />CONSTRUCTIONCONST. <br />DIA. ( ) <br />DIAPH. <br />DEPT. <br />D.F. <br />DIAG. <br />DIM. <br />DN. <br />do <br />CONT. <br />CTR. <br />C.Y. <br />d <br />DBL. <br />CTSK. <br />DEPARTMENT <br />DOUGLAS FIR <br />DIAPHRAGM <br />DIMENSION <br />Ø DIAMETER <br />DIAGONAL <br />DOWN <br />CONTINUOUS <br />CENTER(ED) <br />CUBIC YARD <br />PENNY(NAILS) <br />COUNTERSINK <br />DOUBLE <br />CAMB.(C) <br />CONN. <br />CL. OR <br />C.J. <br />CLG. <br />CLR. <br />CMU. <br />COL. <br />CONC. <br />BTWN. <br />CANT. <br />C.F. <br />C.G. <br />C.I.P. <br />CONSTRUCTION JOINT <br />CENTER LINE <br />CONCRETE <br />CONNECTION <br />CONC. MASONRY UNIT <br />CEILING <br />CLEAR <br />COLUMN <br />L(C) <br />CAMBER(ED) <br />CANTILEVERED <br />CAST IN PLACE <br />CUBIC FEET (FOOT) <br />CENTER OF GRAVITY <br />BETWEEN <br />VERIFY IN FIELD <br />VERTICAL <br />UNLESS NOTED OTHERWISE <br />UNIFORM BUILDING CODE <br />WELDED WIRE FABRIC <br />WELDED STUD(S) <br />WEAKENED PLANE JOINT <br />WORK POINT <br />WIDE (WIDTH) <br />DOUBLE EXTRA STRONG <br />EXTRA STRONG <br />OPEN WEB JOISTS <br />OUTSIDE DIAMETER <br />ON CENTER <br />ORIENTATE(ION) <br />OPENING <br />OPPOSITE HAND <br />OUTSIDE FACE <br />O.C. <br />ORNT. <br />OPNG. <br />O.H. <br />O.F. <br />O.D. <br />XX-STG <br />YD YARD <br />NON-SHRINK GROUT <br />MTL.METAL <br />NOT TO SCALE <br />NEAR SIDE <br />NUMBER <br />NEW <br />N.T.S. <br />N.S.G. <br />N.S. <br />NO. (#) <br />(N) <br />MACHINE BOLT <br />MECHANICAL <br />MEZZANINE <br />MANUFACTURER <br />MISCELLANEOUS <br />MINI-LAM-BM. <br />MINIMUM <br />M.B. <br />MECH. <br />MEZZ. <br />MFR. <br />MISC. <br />MLB <br />MIN. <br />WOODWD. <br />X-STG <br />WWF <br />WT <br />W.S. <br />WPJ <br />W.P. <br />WEIGHT <br />VIF <br />VERT. <br />U.N.O. <br />UBC <br />w/ <br />(W) <br />WITH <br />SQUARE <br />SIMILAR <br />SELECT STRUCTURAL <br />SPECIFICATION(S) <br />SPACE(S)(ING) <br />SKEW(ED) <br />SHEATHING <br />STAGGER(ED) <br />SYMMETRICAL <br />SUSPENDED(TION) <br />STRUCTURAL <br />STIRRUP(S) <br />STIFFENER(S) <br />TOP AND BOTTOM <br />TOP OF WALL <br />TOP OF SHEATHING <br />TOE NAIL <br />TEMPORARY <br />THREADED <br />THICK(NESS) <br />TONGUE AND GROOVE <br />TEMPERATURE <br />TYPICAL <br />TOP OF STEEL <br />TRANSVERSE <br />STANDARD <br />SYMM.K KIPS (1000) <br />LINEAR FEET (FOOT) <br />LGTH LENGTH <br />LONG LEG HORIZ. <br />LONG LEG VERT. <br />LIGHT WEIGHT <br />MASONRY <br />MATERIAL <br />MAXIMUM <br />LLH <br />LLV <br />LT.WT. <br />MAS. <br />MAT'L. <br />MAX. <br />LATERAL <br />POUNDS <br />LAG BOLTS <br />LEDGER <br />LONG(ITUDINAL) <br />LAT. <br />LB (#) <br />L.B. <br />LDGR <br />L.F. <br />LG. <br />TMPRY. <br />TRANSV. <br />T.O.W. <br />T.O.S. <br />T.N. <br />TYP. <br />T.S. <br />T & B <br />T & G <br />THRD. <br />THK. <br />TEMP. <br />(T)TOP <br />INCH(ES) <br />INTERIOR <br />JOIST <br />JOINT <br />INSIDE FACE <br />IN. (") <br />INT. <br />JST. <br />JT. <br />I.F. <br />HEADER <br />HANGER <br />HORIZONTAL <br />HIGH STRENGTH BOLTS <br />HEIGHT <br />INSIDE DIAMETER <br />INVERT ELEVATION <br />HDR. <br />HGR. <br />HORZ. (H) <br />HSB <br />HT. <br />I.D. <br />I.E. <br />STRUC. <br />SUSP. <br />STL. <br />STIR. <br />STIFF. <br />STGR. <br />STD. <br />STEEL <br />SHT. <br />SS <br />SQ. <br />SPEC. <br />SPC. <br />SKW. <br />SIM. <br />SHTG. <br />SHEET <br />STRUCTURAL ABBREVIATIONS <br />APPROXIMATE(LY)APPRX. <br />BNDRY. <br />BLKG. <br />BM. <br />B.N. <br />B.O.F. <br />BRDG. <br />BRG. <br />ARCH. <br />& OR <br />@ <br />B.F. <br />BLDG. <br />BLK. <br />BEL. <br />BLOCKING <br />BOUNDARY <br />BRIDGE(ING) <br />BOUNDARY NAILING <br />BOTTOM OF FOOTING <br />BEAM <br />BEARING <br />ARCHITECT(TURAL) <br />BRACED FRAME <br />AND <br />AT <br />BUILDING <br />BLOCK <br />BELOW <br />A.B. <br />ABV. <br />ADD'L <br />ADJ. <br />ALUM. <br />ALT. <br />ANCHOR BOLT <br />ADDITIONAL <br />ADJACENT <br />ALUMINUM <br />ALTERNATE <br />ABOVE <br />RIDGE BOARD <br />PARALLEL <br />PRECAST CONCRETE <br />PERPENDICULAR <br />PARALLEL STRAND LUMBER <br />PLYWOOD <br />POUNDS PER SQUARE FOOT <br />POUNDS PER SQUARE INCH <br />PRESSURE TREATED <br />POSTTENSIONED <br />(PRESTRESSED) <br />QUANTITY <br />REINFORCED CONCRETE PIPE <br />REFERENCE <br />REINFORCEMENT(ING) <br />REQUIRED <br />RIGID FRAME <br />ROUGH OPENING <br />P.S.F.F.O.C.FACE OF CONCRETE <br />FACE OF MASONRY <br />GLUED LAMINATED BEAM <br />GYPSUM WALLBOARD <br />GAUGE <br />GALVANIZED <br />GRADE BEAM <br />GRADE <br />GA. <br />GALV. <br />GB <br />GLB <br />GRD. <br />GYPDB. <br />FACE OF STUD <br />FACE OF WALL <br />FRAME(ING) <br />FOOT (FEET) <br />FOOTING <br />FAR SIDE <br />F.O.M. <br />F.O.S. <br />F.O.W. <br />FRM. <br />FT. (') <br />FTG. <br />F.S. <br />RAD. (R) <br />REQ'D. <br />R.B. <br />R.C.P. <br />REF. <br />REINF. <br />R.F. <br />R.O. <br />P.S.I. <br />P.T. <br />P/T <br />QTY. <br />RADIUS <br />FABRICATION <br />FOUNDATION <br />FINISH(ED) <br />FLANGE <br />FLOOR <br />FIELD (FACE) NAIL <br />FAB. <br />FND. <br />FIN. <br />FLG. <br />FLR. <br />F.N. <br />PAR. (//) <br />P <br />PERP. ( ) <br />PL. ( ) <br />P/C <br />PSL <br />PLY. <br />L PLATE <br />OWJ. <br />E.S.EDGE SCREWS <br />FIELD VERIFYF.V. <br />4. <br />5. <br />6. <br />THE MAXIMUM THICKNESS APPROVED FOR THE USE IS 14" WITH THE EXCEPTION <br />FIBREBOLTS WHICH ARE LIMITED TO 12" AND 5 8" DIAMETER BOLTS. <br />PRODUCTS SHALL BE LABELED OR PACKAGE CLEARLY IDENTIFYING THE PRODUCT AS <br />EXTREN 525 MANUFACTURED BY STRONGWELL COMPANY. <br />7. <br />THE MAXIMUM ALLOWABLE TENSILE LOAD FOR 12" & 5 8" DIAMETER BOLTS SHALL BE 550 LBS., <br />AND682 LBS. RESPECTIVELY, THE MAXIMUM ALLOWABLE SHEAR LOAD FOR THE 12" AND 5 8" <br />DIAMETER BOLTS SHALL BE 861 LBS. AND 1052 LBS. RESPECTIVELY. <br />6 <br />2. <br />1. <br />PROPERTIES OF FRP: <br />FU= 30,000 PSI <br />FIBERGLASS REINFORCED PLASTIC IS A COMPOSITE CONSISTING OF A PLASTIC RESIN <br />MATRIX REINFORCED BY EMBEDDED GLASS FIBERS. <br />FIBERGLASS REINFORCED PLASTIC (FRP) <br />3.ANCHOR BOLTS SHALL BE 1/2"Ø FRP BOLTS UNLESS NOTED OTHERWISE. <br />E= 2.6x10 PSI <br />8. <br />9.THE FIBERGLASS PRODUCT SHALL PROTECTED WITH AN MFG APPROVED UV INHIBITOR. <br />THE DESIGN OF ALL FRP STRUCTURAL SHAPES, EXCLUDING BOLTS EXCEPT AS APPROVED <br />HEREIN, SHALL BE IN ACCORDANCE WITH THE ASCE PRE-STANDARD FOR LOAD & <br />RESISTANCE FACTOR DESIGN (LRFD) OF PULTRUDED FIBER REINFORCED POLYMER (FRP) <br />STRUCTURES. <br />ONLY FIBERGLASS NUTS SHALL BE USED WITH THE FIBREBOLTS, STEEL NUTS SHALL BE <br />PROHIBITED. <br />10.ALL FRP MEMBERS SHALL BE IDENTIFIED WITH LARR #25536 AND FIBERGATE LABEL. <br />DESIGN CRITERIA <br />LATERAL LOADS: <br /> A) EARTHQUAKE DESIGN DATA: <br /> SEISMIC IMPORTANCE FACTOR...................................... <br /> OCCUPANCY CATEGORY................................................. <br /> MAPPED SPECTRAL RESPONSE ACCEL.....................Ss <br /> S1 <br /> SITE CLASS......................................................................... <br /> SPRECTRAL RESPONSE COEFF................................SDS <br /> SD1 <br /> SEISMIC DESIGN CATEGORY.......................................... <br /> B) WIND: <br /> BASIC WIND SPEED........................................................ <br /> SITE EXPOSURE.............................................................. <br /> I.......................................................................................... <br />=1.25 <br />=II <br />=1.304 <br />=0.468 <br />=D <br />=1.043 <br />=N/A <br />=D <br />101 MPH <br />= D <br />=1.25 <br />1452 EDINGER AVE. <br />TUSTIN, CALIFORNIA 92780 <br />10 CHURCH CIRCLE <br />ANNAPOLIS, MD 21401 <br />4430 E. MIRALOMA AVE. SUITE D <br />ANAHEIM, CALIFORNIA 92807 <br />S-1 <br />George Gomez, P.E. <br />C VI <br />C 92845 <br />EORGE GOME <br />REGISTERED PROFESSIONALENGINEER <br />STATE OF CAL IFORNIAIL <br />ZG