My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180344_W 4TH - Plan
PBA
>
Building
>
Plans
>
F
>
Fourth St
>
209 W Fourth St
>
10180344_W 4TH - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2021 12:42:34 AM
Creation date
10/25/2020 5:19:27 PM
Metadata
Fields
Template:
Plan
Permit Number
10180344
Full Address
209 W Fourth St
Fully Linked
True
Document Relationships
10180344 - Permit
(Permit - Plan)
Path:
\Building\Permits\F\Fourth St\209 W Fourth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ESR-1112 \ Most Widely Accepted and Trusted Page 4 of 6 <br />drinking water treatment chemicals. The focus of <br />NSF/ANSI Standard 61 as it pertains to adhesive anchors <br />is to ensure that the contaminants or impurities imparted <br />from the adhesive product to the potable water do not <br />exceed acceptable levels. <br />5.0 CONDITIONS OF USE <br />The SET adhesive anchor systems for unreinforced <br />masonry, described in this report, comply with, or are <br />suitable alternatives to what is specified in, those codes <br />listed in Section 1.0 of this report, subject to the following <br />conditions: <br />control program with inspections by ICC-Evaluation <br />Service, LLC. <br />5.9 Anchors are not permitted to support fire-resistive <br />construction. Where not otherwise prohibited by the <br />code, anchors are permitted for installation in fire- <br />resistive construction provided that at least one of the <br />following conditions is fulfilled: <br />• Anchors are used to resist wind or seismic forces <br />only. <br />• Anchors are used to support nonstructural <br />elements. <br />5.1 Use and installation must be as set forth in this <br />evaluation report and the manufacturer's published <br />installation instructions (MPII) shown in Figure 2. In <br />case of conflict, this report governs. <br />5.2 Calculations and details must be submitted to the <br />code official for approval. <br />5.3 Special inspection must be in accordance with <br />Section 4.5 of this evaluation report. <br />5.4 Use of the anchor system must be approved by the <br />registered design professional. <br />5.5 Anchors must be limited to resisting transient wind or <br />6.0 EVIDENCE SUBMITTED <br />6.1 Data in accordance with the ICC-ES Acceptance <br />Criteria for Anchors in Unreinforced Masonry <br />Elements (AC60), dated December 2009 (effective <br />January 2010). <br />6.2 A quality control manual. <br />6.3 Data in accordance with NSF/ANSI Standard 61, <br />Drinking Water System Components-Health Effects, <br />for the SET adhesive. <br />7.0 IDENTIFICATION <br />seismic loads only. <br />5.6 Anchors are installed in holes predrilled with a <br />carbide-tipped masonry drill bit complying with ANSI <br />B212.15-1994, using rotation mode only. Impact tools <br />are not permitted <br />5.7 The adhesive must not be used after the expiration <br />date stamped on the cartridge. <br />5.8 The SET adhesive is manufactured and packaged <br />into the cartridges described in this report by <br />Simpson Strong-Tie Company, Inc., under a quality <br />Simpson Strong-Tie SET adhesive anchoring systems are <br />identified in the field by labels on the cartridges or <br />packaging,bearing the company name <br />(Simpson Strong-Tie Company, Inc.), the product name <br />(SET22, SET56, or SET-PAC-EZ), the batch number, the <br />expiration date, the name of the inspection agency <br />(ICC-ES),and the evaluation report number <br />(ESR-1772). Screen tubes are identified by a label on the <br />packaging, bearing the Simpson Strong-Tie name and the <br />tube type (plastic or metal) and size. <br />TABLE 1-MANUFACTURER'S GEL TIMES AND CURING TIMES FOR SET ADHESIVES1 <br />TEMPERATURE (°F)GEL TIME2 (hours)INITIAL CUREZ (hours) <br />40 2 72 <br />65 11/4 24 <br />85 1 20 <br />90 1 16 <br />For SI: 1°C = 5/9 (FF-32) <br />1Anchors installed or cured at temperatures below 40°F (4.4°C) are outside the scope of this report. <br />2Anchors must be not be disturbed after the gel time until the cure time has elapsed, and must be allowed to reach initial cure before <br />attachment of building components. <br />TABLE 2-SPACING AND EDGE DISTANCE REQUIREMENTS FOR SET ADHESIVE ANCHOR SYSTEMS <br />INSTALLED IN UNREINFORCED MASONRY <br />ANCHOR <br />ASSEMBLY <br />Shear anchor or rebar dowel <br />Configuration A <br />221/2° combination anchor <br />Configuration B <br />MINIMUM VERTICAL SPACING MINIMUM HORIZONTAL SPACING MINIMUM EDGE DISTANCE <br />(inches)(inches)(inches) <br />16 16 16 <br />16 16 16 <br />Through-bolt anchor 16 1616Configuration C
The URL can be used to link to this page
Your browser does not support the video tag.