My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3925_Hazard_P0115656_2024-194175_Grading - Plan (2)
PBA
>
Building
>
ProjectDox
>
H
>
Hazard Ave
>
3925 W Hazard Ave Unit# 2
>
3925_Hazard_P0115656_2024-194175_Grading - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 7:46:09 AM
Creation date
8/13/2025 11:26:56 AM
Metadata
Fields
Template:
Plan
Permit Number
P0115656
Full Address
3925 W Hazard Ave Unit# 2
Street Number
3925
Street Direction
W
Street Name
Hazard
Street Suffix
Ave
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY <br />Project Name Date <br /> <br />System Name Floor Area <br /> <br />ENGINEERING CHECKS SYSTEM LOAD <br />Number of Systems COIL COOLING PEAK COIL HTG. PEAK <br />Heating System CFM Sensible Latent CFM Sensible <br /> Output per System Total Room Loads <br /> Total Output (Btuh) Return Vented Lighting <br /> Output (Btuh/sqft) Return Air Ducts <br />Cooling System Return Fan <br /> Output per System Ventilation <br /> Total Output (Btuh) Supply Fan <br /> Total Output (Tons) Supply Air Ducts <br /> Total Output (Btuh/sqft) <br /> Total Output (sqft/Ton) TOTAL SYSTEM LOAD <br />Air System <br /> CFM per System HVAC EQUIPMENT SELECTION <br /> Airflow (cfm) <br /> Airflow (cfm/sqft) <br /> Airflow (cfm/Ton) <br /> Outside Air (%) Total Adjusted System Output <br /> Outside Air (cfm/sqft) (Adjusted for Peak Design conditions) <br />Note: values above given at ARI conditions TIME OF SYSTEM PEAK <br />HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />NEW DETACHED ADU 4/22/2024 <br />SHP 1,000 <br />1 <br />24,000 <br />24,000 <br />24.0 <br />24,000 <br />24,000 <br />2.0 <br />24.0 <br />500.0 <br />800 <br />800 <br />0.80 <br />400.0 <br />0.0% <br />0.00 <br />239 <br />7,460 <br />0 <br />0 <br />0 <br />0 <br />0 <br />335 <br />9,608 <br />0 <br />0 <br />00 <br />335 <br />0 <br />239 <br />75921,614 <br />5447,938 <br />21,614 <br />17,930 <br />759 17,930 <br />SHP <br />Aug 3 PM Jan 1 AM <br />282 544 445 <br />33 ºF <br />Outside Air <br />0 cfm <br />70 ºF 70 ºF 90 ºF <br />90 ºF <br />800 cfm <br />Supply Fan <br />70 ºF 70 ºF <br />91 / 70 ºF 78 / 61 ºF 78 / 61 ºF 53 / 52 ºF <br />53 / 52 ºF <br />78 / 61 ºF78 / 61 ºF <br />0 cfm <br />Outside Air <br />38.3% <br />Heating Coil <br />10,278 <br />800 cfm <br />Supply Fan Cooling Coil
The URL can be used to link to this page
Your browser does not support the video tag.