#ANH. <br />'NA.M <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box '1988 (M-'19) <br />Santa Ana. C492702 <br />(714) 647.s800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be altached to each of.TWO sets of plans, of <br />minimum 11'x 17' size. lf answerinq NO to anv of the q uestions. plan check shall be required <br />b <br />tr <br />\roo\.r <br />) <br />4 <br />5 <br />2 <br />3 <br />o <br />7 <br />YES <br />h <br />\ <br />\ <br />E <br />N <br />q <br />No Are the following applicable to the proposed project? <br />tr U/ill the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the California Fire Code, and is this shown on the roof plan? <br />tr \ /ill the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />tr U/ill the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are paralLel to the plane of the roof? <br />tr \r'/lil the PV system welgh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />\ /ill the PV system be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />I <br />10 <br />U/lll the PV systern be installeC without using any ballast systen'] or counter-weight <br />system? <br />\y'/ill the anchors be lnstalled with a maximum horizontal anchor spacing of 6 feei <br />and is this maximum horizontal spacing shown on the p{ans? <br />\ /ill the minimum 5/16" lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans stamped and signed by a California <br />licensed professional engineer? (including project speciflc site plan, PV layout, <br />anchorage spacing, anchorage details and maoufacturer's PV support information.) <br />lcertify under penalty f per,lury under the laws of the State of Cal <br />Signature <br />Phone Number <br />\tr <br />\u <br />Ntr <br />Nu <br />6 -S <br />Email Address <br />Rev I1i 19i 2015 <br />-"6 q Date <br />the ab is true <br />s: t t:rtt l <br />Project Address: <br />Contractor Company Name: <br />Contractor License Number: <br />1 <br />Print Name: