39 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 <br />3. These Class 2 LED modules are each rated as noted in the model list tables. When units are connected to a Class 2 circuit, <br />they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Vdc or less. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />6. For M601C series, three units are consisted one module. <br />7. The suitability of supply leads shall be determined in end use. <br />Class 2 powered LED m o d u l e s, C a t . N o s . E M 1 0 2, E M 1 2 0, E M 1 1 2, E M 3 2 4, E M 2 2 5, E M 3 3 2, E M 2 2 0, E M 3 2 6, E M 3 4 0 . <br />1. This product is only suitable for connection to a Class 2 power source, rated 12 Volt DC or less. <br />2. This product has not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and <br />energy limits and which is rated greater than electrical ratings. <br />3. This Class 2 LED module is rated as noted in the electrical ratings tables. When units are connected to a Class 2 circuit, they <br />are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. <br />4. This product is suitable for use in dry, damp and wet locations with supply sources rated at electrical ratings or less. <br />5. This product is not required to be enclosed or protected from the weather in the end product. <br />6. This product may be secured in place in the end products by any means available. <br />ELECTRALED INC E232462 <br />SUITE 105 <br />10950 72 ND ST N <br />LARGO, FL 33777 <br />LED Channel Letter Lighting System, Cat. Nos.Series 12 (ES12-), Series 24 (ES24-) and Series 12 Genesis (EG-12). <br />1. These LED products are suitable for use in dry, damp, and wet locations <br />2. These products are only suitable for connection to a Listed Class 2,12 or 24 V power source; or a R/C Class 2 power supply <br />covered in the Sign Components manual (SAM) and used within its published conditions of use; or a power supply specifically <br />covered by this report. <br />3. These products may be pre-wired with the conductors cut to length per the installation instructions, or the product may be <br />provided with terminals <br />4. Printed circuit boards with LED's are supplied in 2,4,6 or 12 in. lengths. <br />5. ElectraLED LED's may be powered by R/C (XOKV2) Powertronix Corp. Model AA-036539-D, Class 2 transformer. The <br />transformer shall be provided with a maximum 5 Amp LISTED fuse on the secondary output prior to the printed circuit boards. <br />The LEDs must be mounted in a suitable sign body in accordance with UL 48. The transformer shall be mounted in a suitable <br />electrical enclosure in accordance with UL 48 having a minimum volume of 52.0 cubic inches. In the end-product, a replacement <br />of fuse marking shall be supplied adjacent to the fuse indicating "Replace with same type and rating of protective device." <br />6. Enclosure surface to secure the standoffs for printed wiring boards shall be aluminum or as follows: <br />7. Standoffs may be secured to acrylic UYMR2 Sign Accessory Rigid Sign Face Material or polycarbonate UYMR2 Sign Accessory <br />Rigid Sign Face Material using QOQW2,3M double sided tape designated 4950 provided enclosure has a minimum 30.0 cubic <br />inches of volume per 12 inches of LED printed circuit boards. <br />8. These products have not been evaluated for use when not connected to a Class 2 voltage and energy requirements when <br />installed per the manufactures installation instructions. <br />LED Channel Letter Lighting System, Cat. Nos. ELED-5 or -6. <br />1. ElectraLED ELED-5 and ELED-6 are intended for Dry, Damp and Wet Location use only when LED's are connected to a <br />Class 2 circuit operating at under 30V continuous DC, 12.4 V interrupted at a rate of 10-200Hz DC, or 15 VAC. Wet Location <br />use meaning no additional electrical enclosure or sign body is required for the LEDs. <br />2. ElectraLED ELED-5 and ELED-6 are intended for Dry and Damp Locations use only when LED's are connected to a Class 2 <br />circuit operating at a potential greater than under 30V continuous DC, 12.4 V interrupted at a rate of 10-200Hz DC, or 15 <br />VAC. If the LEDs are connected to a Class 2 circuit operating at a potential greater than under 30V continuous DC, 12.4 V <br />interrupted at a rate of 10-200Hz DC, or 15 VAC then a Sign Body per UL 48 must be maintained to house the LEDs. <br />3. ElectraLED ELED-5 and ELED-6 LED's may be powered by a UL Listed or Recognized Component Sign Accessory - <br />UYMR2, Class 2, output power source. See Conditions of Use No. 1 and No. 2 above for additional details regarding <br />enclosure requirements. <br />4. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 <br />voltage and energy limiting requirements. <br />5. These products are not to draw a total wattage greater than the secondary or output rating of the Class 2 supply per Class 2 <br />circuit. <br />6. These products may be prewired and the conductors may be cut to length per the installation instructions provided with the <br />product or the product may be provided with terminals. Printed circuit boards with LED's may be supplied in 2,4,6 or 12 in. <br />lengths. <br />7. Enclosure surface to secure the standoffs for printed wiring boards shall be aluminum or as follows: <br />7A. Standoffs may be secured to acrylic UYMR2 Sign Accessory Rigid Sign Face Material or polycarbonate UYMR2 Sign <br />Accessory Rigid Sign Face Material using QOQW2,3M double sided tape designated 4950 provided enclosure has a <br />minimum 30.0 cubic inches of volume per 12 inches of LED printed circuit boards. <br />8. The ELED-5 system may be supplied with a Powertronix Corp. Model AA-036539-D, Class 2 transformer. The transformer <br />shall be provided with a maximum 5 Amp LISTED fuse on the secondary output prior to the printed circuit boards. The ELED- <br />5 system may consist of either: 20 feet maximum of red, yellow or orange LEDs OR 16 feet maximum of white, blue or green <br />LEDs. The LEDs must be mounted in a suitable sign body in accordance with UL 48 when the ELED-5 system with the <br />Powertronix Corp. Model AA-036539-D transformer and 5 A fuse as described above is utilized. The transformer shall be <br />mounted in a suitable electrical enclosure in accordance with UL 48 having a minimum volume of 52.0 cubic inches. If used <br />outdoors, the transformer must be mounted in an outdoor electrical enclosure per UL 48 having a minimum volume of 52.0 <br />cubic inches. In the end-product, a replacement of fuse marking shall be supplied adjacent to the fuse indicating "Replace <br />with same type and rating of protective device." <br />9. The ELED-6 system may be supplied with a Lightech Model LET-60, Class 2 transformer. The loading of the transformer shall <br />not exceed 5.0 amps. The ELED-6 system may consist of either: 20 feet maximum of red, yellow or orange LEDs OR 16 feet <br />maximum of white, blue or green LEDs.