My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1601 N Bristol St - Wall - Phase 1 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
1601 N Bristol St
>
1601 N Bristol St - Wall - Phase 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2025 5:00:09 AM
Creation date
8/28/2025 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101124645
Full Address
1601 N Bristol St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Cantilevered Retaining Wall <br />LIC# : KW-06014996, Build:20.24.05.02 Gerry Adriano (c) ENERCALC INC 1983-2023 <br />DESCRIPTION:8 ft high wall_L Type Ftg <br />Project File: Bristol_better buzz.ec6 <br />Project Title:Better Buzz_Bristol <br />Engineer: <br />Project ID: <br />Project Descr:Retaining Wall <br />Code References <br />Calculations per IBC 2012 1807.3, CBC 2013, ASCE 7-10 <br />3.00 <br />5.00 <br />0.00 <br />8.00 <br />1,200.0 <br />45.0 <br />0.0 <br />250.0 <br />Criteria Soil Data <br />Retained Height =ft <br />Wall height above soil =ft Active Heel Pressure =psf/ftSlope Behind Wall <br />Height of Soil over Toe in <br />Water table above <br />=ft = <br />= <br />110.00=pcf <br />= <br />Soil Density, Heel <br />= <br />Passive Pressure =psf/ft <br />Allow Soil Bearing =psf <br />Soil Density, Toe 110.00 pcf <br />Footing||Soil Friction =0.400 <br />Soil height to ignore <br />for passive pressure =12.00 in <br />Equivalent Fluid Pressure Method <br />bottom of footing <br />Surcharge Loads Adjacent Footing Load <br />Load Type <br />0.0 Lateral Load =0.0 #/ft <br />0.0 <br />0.0 <br />0.0 <br />0.0 <br />Axial Load Applied to Stem <br />Wall to Ftg CL Dist =0.00 ft <br />Wind on Exposed Stem psf17.0= <br />Lateral Load Applied to Stem <br />Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs <br />Axial Dead Load <br />(Service Level) <br />=lbs <br />Footing Type Spread Footing <br />Surcharge Over Toe <br />Footing Width =0.00 ft...Height to Top =0.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft <br />NOT Used To Resist Sliding & Overturning <br />NOT Used for Sliding & Overturning <br />==0.0 ft <br />Axial Live Load = <br />Base Above/Below Soil <br />lbs <br />= <br />Axial Load Eccentricity ==Poisson's Ratio 0.300 <br />at Back of Wall <br />in <br />(Service Level) <br />Wind (W)=
The URL can be used to link to this page
Your browser does not support the video tag.