October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 52
<br />4. In the end product, power supply spacing to other heat producing comp0nents shall be minimum i2 ihches spacing to sidewalls,
<br />and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in, in
<br />any other direction.
<br />5. These components shall be installed inside an electrical enclosure.
<br />6 Input and Output leads are style 1316, rated 600 V, 105 C, VW-1. Minimum No. 18 AWG. The suitability ofinput and output
<br />connections shall be determined in each end use application.
<br />7 The maximum room ambient temperature permitted by the manufacture is 60 C. The temperature measured on outside
<br />enclosure of Models GEPS24-20 and GEPS12-20 are 67.2 C and 77.9 C respectively. The necessity of repeated Temperature
<br />Test shall be determined in each end use application if minimum thermal spacings in accordance with Item 4 are not provided.
<br />LED Dimmer, Model GEDM 1 and GEDM 1-A.
<br />1 This component has been judged on the basis of the required spacing in the Standard for Class 2 Power Units, UL 1310, Fourth
<br />Edition, which would cover the component itself if submitted for Listing.
<br />2. The equipment was submitted and tested for a maximum manufacturers recommended 'ambient (Tmra) of 40 C.
<br />3. The unit is intended for installation inside an electrical enclosure.
<br />4. This unit is provided with a Class 105(A) insulation system. The unit may betused within an eleckical enclosure or raceway
<br />without temperature test provided they are mounted not closer than 1 in. end to end or 4 im. side to side from adjacent LED
<br />power supplies.
<br />5. The Xitanium Dimmer is ionly suitable for use in Class 2 circuits powered by Advance LED drivers with maximum input rating of
<br />24Vdc, 4.l A, or 12VDC, 5A. Dimmer circuit is 0-10VDC:
<br />6. This LED Dimmer Controller muit be used with either a 100K Ohms Potentiometer or a standard 0-10 V DC dirnmer switch.
<br />7 For dry or damp location.
<br />LED Strips, Class 2, Cat. Nos. GE-XX-XX-X-XXX, GE-XX-XX-XX-XXX, GE-XX-XX-XXX-XXX, GE-XX-XX-XXXX2XXX, GE-XX-
<br />XX-XXXXX-XXX, GE-XX-XX-XXXXXX-XXX, GE-XX-XX-XXXXXXX-XXX, GE-XX-XX-XXXXXXXX-XXX, GE-XX-XX-
<br />XXXXXXXXX-XXX, catalog numbers may vary per nomenclature. GE followed by: ''XX" representing color: RD, RC, YG, GL,
<br />SB, BL, WH, YA, VWV, GR, PO. followed by: "XX" representing product line: CL, DS, XL. PT, XN. TM, MX, TU, PG, PX, PH, XH,
<br />MH, SS, PM. MM, MH, BS, BD, BI followed by. "X" to "XXXXXXXXX" representing light strip final assembly or number of LEDs
<br />per foot: LA, LE, AA, SX, LX, WXX, TXX, PX, XX followed by: ''XXX" denotes any alphanumeric character that represents the
<br />color temperature of the LEDs. Cat. Nos. GE-AA-BB-CC, where'AA" may be DS, XN, XNL, XNA, MX, MXL, PG, MM, MMD, SS,
<br />PM, PMD, MXH, MXHL, BS, BD, Bl, BIH, BSH, BDH, DSH or SSH which represent product line: "BB" may be RD, RC, YG, GL,
<br />SB, BL, WH, YA, WW, GR, PO or any alphanumeric character; and -CC" may be any alphanumeric characters or blank.
<br />1- These products are only suitable for connection to a Class 2 power source.
<br />2. When units are connected to a Class 2/ LPS circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2/ LPS supply.
<br />3. These products are suitable for use in dry, damp and wet locations.
<br />4. These products described in this section may be cut into segments per manufacture insulation instructions.
<br />5. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 Conditions of
<br />Use as defined in the Sign Components Manual.
<br />6. The Light Guide has notbeen evaluated as an LED Strip Light enclosure or diffuser. Suitability shall be determined in the end
<br />use product.
<br />NOMENCLATURE:
<br />Nomenclature for LED Strip Light: GE-XX-XX-X-XXX, GE-XX-XX-XX-XXX, GE-XX-XX-XXX-XXX. GE-XX-XX-XXXX-XXX, GE-XX-
<br />XX-XXXXX-XXX, GE-XX-XX-XXXXXX-XXX, GE-XX-XX-XXXXXXX-XXX, GE-XX-XX-XXXXXXXX-XXX, GE-XX-XX-XXXXXXXXX-
<br />XXX.
<br />First Set of "XX" = denotes the color of the LED
<br />RD = Red family
<br />RC =Red/Orange family
<br />YG = yellow family
<br />GL =Green family
<br />SB, BL = Blue Family
<br />WH = White
<br />YA = Amber
<br />VAN = Warm White
<br />GR =Green
<br />PO = Portland Orange
<br />Second Set of "XX" = denotes product line
<br />CL = channel letter
<br />DS = double sided Power Strip
<br />XL =tetra long strip
<br />PT = power tetra
<br />XN. XNL, XNA =Contour or Contour LS
<br />TM =Mini
<br />MX. MXL = Max
<br />TU = Ultra
<br />PG =Power Grid
<br />PX = Power White XL
<br />PH = Power White HO
<br />XH = Power White XL HO
<br />MM, MMD =Mini Max
<br />SS = Power Strip
|