My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2350 S Pullman St - DEF - Exterior & Interior Framing - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pullman St
>
2350 S Pullman St
>
2350 S Pullman St - DEF - Exterior & Interior Framing - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2025 5:00:12 AM
Creation date
9/6/2025 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101124188
Full Address
2350 S Pullman St
Jump to thumbnail
< previous set
next set >
Polygon
ID:
1
Creator:
Import Agent
Created:
9/6/2025 5:00 AM
Modified:
9/4/2025 12:27 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONT. SEALANT AT EACH <br />VERTICAL PANEL JOINT <br />CONT. PANEL ATTACHMENT ANGLE <br />WELDED TO STRUCTURAL STEEL - <br />SEE STRUCTURAL DRAWINGS <br />COLD SIDE <br />SET 18 GA. GALV. STL. CAP CHANNEL <br />IN A CONT. FULL BEAD OF WATER <br />BLOCK SEALANT IN EACH CORNER <br />AND EACH VERTICAL LEG. ATTACH <br />TO PANEL W/ LOW-PROFILE SCREWS <br />AT 12" O.C. <br />ADHERE ROOF FLASHING MEMBRANE <br />TO WALL CAP W/ CONT. BONDING <br />ADHESIVE; PROVIDE FULL BED OF <br />WATER BLOCK SEALANT UNDER <br />VERTICAL TURN-DOWN <br />COMPLETELY FILL LOW AT ALL <br />PANEL JOINTS AND LOWS <br />BETWEEN JOINT W/ POLY- <br />URETHANE SEALANT TO <br />ACHIEVE SMOOTH SURFACE <br />CONT. 22 GA. STAINLESS STEEL <br />CLEAT FASTENED THRU CONT. <br />CAULKING TAPE @ 6" O.C.; SEAL <br />ALONG BOTTOM W/ URETHANE <br />CAULKING <br />ADHERE MEMBRANE TO FACE <br />OF IMP AND SEAL W/ WATER <br />BLOCK SEALANT <br />ROOF MEMBRANE <br />CUT EDGE SEALANT <br />HOT-AIR WELD <br />CONTINUOUS BONDING ADHESIVE <br />26 GA. GALV. STEEL CAP <br />FLASHING W/ FINISH TO <br />MATCH PANEL <br />ROOF INSULATION <br />SLOPE <br />ALL FASTENERS THRU 1/8" <br />SEALANT TAPE <br />FIP INSULATION <br />FULLY ADHERED ROOF <br />MEMBRANE <br />2" SEAM PLATES @ 6" O.C. <br />MI <br />N <br />. <br /> <br />8 <br />" <br />HOT-AIR WELD <br />WORK TO BE COMPLETED BY IMP CONTRACTOR WORK TO BE COMPLETED BY ROOFING CONTRACTOR <br />2" RIGID INSULATION FULLY <br />ADHERED OR MECHANICALLY <br />FASTENED <br />TREATED WOOD BLOCKING - <br />PROVIDE 1/4" ROUTED EDGE <br />PROVIDE HIDDEN SIDE-LAP <br />FASTENERS PER IMP MANUF. <br />DIRECTIONS <br />NOTE: <br />1. APPLY CUT EDGE SEALANT TO ALL CUT REINFORCED <br />MEMBRANE EDGES. <br />COLD SIDE <br />FULLY ADHERED <br />ROOF MEMBRANE <br />HOT-AIR WELD <br />2" SEAM PLATES @ 6" O.C. <br />COMPRESSIBLE INSULATION <br />SPONGE TUBE DIAMETER TO <br />EXCEED OPENING BY >50% <br />ROOF INSULATION <br />METAL ROOF DECK <br />RETAINER TO BE BREATHABLE <br />FABRIC SUCH AS TYVEK OR <br />APPROVED EQUAL. <br />STEEL BEAM <br />EXIST METAL DECK <br />FLASHING MEMBRANE, FULLY <br />ADHERE TO METAL TRANSITION <br />EXIST EXT. CONC. WALL <br />MI <br />N <br />. <br />8" <br />FULLY ADHERED MEMBRANE <br />FLASHING <br />CONT. STAINLESS STEEL <br />TERMINATION BAR; ATTACH @ 6" O.C. <br />POURABLE CAULKING <br />24 GA. PREF. GALV. STEEL COUNTER <br />FLASHING FASTENED W/ #10 SCREWS <br />12" O.C. THRU CONT. 3" SEALANT TAPE <br />1/2" SEALANT AND BACKER ROD <br />E.J. <br />6" <br />3 <br />1 <br />/ <br />2 <br />" <br />CUT 3 1/2" NOTCH IN EIFS TO EXPOSE <br />EXIST SHEATHING <br />FULLY ADHERED <br />ROOF MEMBRANE <br />HOT-AIR WELD <br />2" SEAM PLATES @ 6" O.C. <br />COMPRESSIBLE INSULATION <br />SPONGE TUBE DIAMETER TO <br />EXCEED OPENING BY >50% <br />ROOF INSULATION <br />METAL ROOF DECK <br />RETAINER TO BE BREATHABLE <br />FABRIC SUCH AS TYVEK OR <br />APPROVED EQUAL - FULLY ADHERED <br />AT CONC. WALL & WD. BLOCKING <br />STEEL BEAM <br />6" <br />FLASHING MEMBRANE <br />COMPATIBLE W/ EXIST ROOF. <br />SEAL TO EXT. G.W.B. & EXIST <br />ROOF. <br />EXIST METAL DECK <br />EXIST ROOF MEMBRANE <br />5/8" EXT. G.W.B. <br />FLASHING MEMBRANE, HOT AIR <br />WELDED TO METAL TRANSITION <br />EXIST EXT. CONC. WALL <br />CONT. SEALANT (TYP.) <br />(2) CONT. BEADS OF <br />SIKAFLEX 1A SEALANT, OR <br />COMPATIBLE ROOF SEALANT <br />TPO COATED METAL TRANSITION <br />STRIP. SECURE TO BLOCKING AT 4" <br />O.C. STAGGERED. SET IN FULL BED <br />OF WATER BLOCK MASTIC. SNAP TO <br />COMPATIBLE FLASHING MEMBRANE <br />2X WOOD BLOCKING. ATTACH TO TOP <br />OF EXIST. CONC. WALL W/ 3/8" DIA <br />GALV.HILTI HIT-Z X 4 3/8" LONG ANCHOR <br />ROD W/ HILTI HIT-HY200-R V3 ADHESIVE <br />W/ 2 3/8" EMBEDMENT@ 18" O.C. (DO <br />NOT CUT EXISTING REINFORCEMENT) <br />E.J. <br />6" <br />STEEL GIRT - SEE <br />STRUCTURAL DRAWINGS <br />CONT. ANGLES - <br />SEE STRUCTURAL <br />DRAWINGS <br />INSULATED METAL <br />WALL PANEL <br />5/8" DIA. S.S. THRU <br />BOLTS - TYP. W/ NUT & <br />WASHER @ 12" O.C. MAX. <br />PREFINISHED 22 GA. STEEL <br />VENTED SOFFIT <br />PREFINISHED 24 GA. GALVANIZED <br />STEEL FLASHING (EXISTING <br />STANDING SEAM ROOF) <br />PREFINISHED STANDING SEAM 24 <br />GA. GALVANIZED STEEL ROOF <br />1/2" NONSTRUCTURAL GLASS <br />MAT GYPSUM ROOF BOARD <br />15# FELT 362S162-54 @ 12" O.C. <br />ATTACH TO TOP & BOT <br />TRACK W/(1) #10 SCREW <br />PER FLANGE. <br />B-402-1 <br />G <br />B-402-1 <br />E <br />B-402-1 <br />F <br />4' - 0" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />600S162-54 @ 12" O.C. ATTACH <br />TO EACH END TRACK W/(1) #10 <br />SCREW PER FLANGE. <br />362S162-54 @ 12" O.C. ATTACH @ <br />EA STUD OVERLAP W/(4) #10 <br />SCREWS PER RAFTER @ 2" MIN. <br />SPACING IN EA. DIRECTION <br />18 GA X 7/8" HAT CHANNEL @ 16" <br />MAX OR AS REQ BY ROOF <br />MANUFACTURER. ATTACH W/ (2) # <br />10 SCREWS PER RAFTER <br />2" X 2" X 3" 16 GA CLIP ANGLE <br />W/(4) #10 SCREWS TO STUD <br />& (2) 1/4" DIA. A307 BOLTS W/ <br />NUT AND WASHER TO STEEL <br />ANGLE. TYP TOP & BOT. <br />2" X 2" X 3" 16 GA CLIP ANGLE <br />W/(4) #10 SCREWS TO STUD <br />& (2) 1/4" DIA. A307 BOLTS W/ <br />NUT AND WASHER TO STEEL <br />ANGLE. TYP TOP & BOT. <br />600T125-54 TYP. BOTH ENDS W/ (1) <br />#10 SCREW EA. FLANGE AND (4) # <br />10 SCREWS TO METAL STUD 362T125-54 TYP. TOP & BOT. <br />2" <br />STEEL GIRT - SEE <br />STRUCTURAL DRAWINGS <br />CONT. ANGLES 4" X 4" X <br />1/4"- SEE STRUCTURAL <br />DRAWINGS <br />INSULATED METAL <br />WALL PANEL <br />5/8" DIA. S.S. THRU <br />BOLTS - TYP. W/ NUT & <br />WASHER @ 12" O.C. MAX. <br />PREFINISHED 24 GA. GALVANIZED STEEL <br />FLASHING (MATCH EXISTING STANDING SEAM <br />ROOF). ATTACH W/ GROMMETED SCREWS. <br />PREFINISHED STANDING SEAM 24 <br />GA. GALVANIZED STEEL ROOF <br />1/2" NONSTRUCTURAL GLASS <br />MAT GYPSUM ROOF BOARD <br />15# FELT <br />362S162-54 @ 12" O.C. ATTACH <br />@ EA STUD OVERLAP W/(4) # <br />10 SCREWS PER RAFTER @ 2" <br />MIN SPACING IN EA. <br />DIRECTION <br />SHIM <br />SLOPE 1/2" <br />SEALANT <br />FOAM-IN-PLACE URETHANE OR <br />DOW CORNING #3-6548 <br />SILICONE RTV RESILIENT FOAM <br />PENETRATION SEALANT, IN <br />AND AROUND PIPE <br />NOTES: <br />1. FOAMING & SEALING TO PROVIDE VAPOR BARRIER CONTINUITY OF <br /> INSULATED WALL PANEL BY CONTRACTOR INSTALLING BOLT. <br />2. DRILL METAL SKIN OF PANEL TIGHT TO BOLT DIAMETER. <br />3. USE URETHANE BASED SEALANT ON INTERIOR AND EXTERIOR OF IMP AT <br /> BOLTS TO FORM AN AIR AND VAPOR TIGHT SEAL. FILL SPACE AROUND <br /> BOLTS WITH FOAM-IN-PLACE URETHANE OR DOW CORNING #3-6548 SILICONE <br /> RTV RESILIENT FOAM PENETRATION SEALANT. <br />URETHANE BASED <br />SEALANT (TYP.) - INTERIOR <br />AND EXTERIOR <br />26 GA GALV. STEEL TRIM W/ <br />FINISH TO MATCH PANELS. <br />ATTACH TO PANELS W/ #10 x <br />3/4" S.M. SCREWS @ 12" O.C. <br />W/ PAINTED HEADS TO <br />MATCH PANELS; THEN <br />SPRING TIGHT AGAINST GIRT <br />FOAM-IN-PLACE INSULATION <br />3/4" DIA S.S. X-STRONG <br />PIPE @ 12" OC, TYP. <br />18 GA X 7/8" HAT CHANNEL @ 12" <br />MAX OR AS REQ. BY ROOF <br />MANUFACTURER. ATTACH W/(2) #10 <br />SCREWS PER RAFTER <br />362S162-54 @ 12" O.C. ATTACH <br />TO TOP & BOT TRACK W/ (1) # <br />10 SCREW PER FLANGE <br />362T125-54 TYP. TOP & BOT W/ <br />(1) #10 SCREW EA. FLANGE <br />2" X 2" X 3" 16 GA CLIP ANGLE W/(4) #10 <br />SCREWS TO STUD & (2) 1/4" DIA. A307 <br />BOLTS W/ NUT AND WASHER TO STEEL <br />ANGLE. TYP TOP & BOT. <br />COMPLETELY FILL PANEL LOWS W/ <br />POLYURETHANE SEALANT TO <br />ACHIEVE SMOOTH SURFACE <br />3/16" <br />TYP. PIPE TO <br />EXTERIOR <br />ANGLE <br />2"STEEL GIRT - SEE STRUCTURAL <br />CONTRACT DOCUMENTS <br />CONT. ANGLES - SEE STRUCTURAL <br />CONTRACT DOCUMENTS <br />5/8" DIA. S.S. THRU BOLTS - TYP. W/ <br />NUT & WASHER @ 12" O.C. MAX. <br />FOAM-IN-PLACE URETHANE OR DOW <br />CORNING #3-6548 SILICONE RTV <br />RESILIENT FOAM PENETRATION <br />SEALANT, IN AND AROUND PIPE. <br />URETHANE BASED SEALANT <br />(TYP.) - INTERIOR AND EXTERIOR <br />26 GA GALV. STEEL TRIM W/ FINISH <br />TO MATCH PANELS. ATTACH TO <br />PANELS W/ #10 x 3/4" S.M. SCREWS <br />@ 12" O.C. W/ PAINTED HEADS TO <br />MATCH PANELS; THEN SPRING <br />TIGHT AGAINST GIRT <br />FOAM-IN-PLACE INSULATION <br />3/4" DIA. S.S. X-STRONG <br />PIPE @ 12" OC, TYP. <br />362S162-54 @ 12" O.C. ATTACH <br />TO TOP & BOT TRACK W/(1) #10 <br />SCREW PER FLANGE. <br />600S162-54 @ 12" O.C. ATTACH <br />TO EACH END TRACK W/(1) #10 <br />SCREW PER FLANGE. <br />362T125-54 TYP. W/ (1) #10 <br />SCREW EA. FLANGE <br />600T125-54 TYP. W (1) #10 <br />SCREW EA. FLANGE AND (4) # <br />10 SCREWS TO METAL STUD <br />2" X 2" X 3" 16 GA CLIP ANGLE <br />W/(4) #10 SCREWS TO STUD <br />& (2) 1/4" DIA. A307 BOLTS W/ <br />NUT AND WASHER TO STEEL <br />ANGLE. TYP TOP & BOT. <br />2"3/16" <br />TYP. PIPE TO <br />EXTERIOR <br />ANGLE <br />PREFINISHED 22 GA. STEEL <br />VENTED SOFFIT <br />PREFINISHED STANDING SEAM 24 <br />GA. GALVANIZED STEEL ROOF <br />1/2" NONSTRUCTURAL GLASS <br />MAT GYPSUM ROOF BOARD <br />15# FELT <br />PREFINISHED 22 GA. 6 X 6 <br />STEEL GUTTER TO MATCH <br />ROOF, W/ 4 X 4 DOWNSPOUT <br />2x8 PT WOOD <br />PREFINISHED 22 GA. <br />STEEL FLASHING <br />362S162-54 @ 12" O.C. ATTACH @ <br />EA STUD OVERLAP W/(4) #10 <br />SCREWS PER RAFTER @ 2" MIN. <br />SPACING IN EA. DIRECTION. <br />18 GA X 7/8" HAT CHANNEL @ 12" <br />MAX OR AS REQ BY ROOF <br />MANUFACTURER. ATTACH W/ (2) # <br />10 SCREWS PER RAFTER <br />600S162-54 @ 12" O.C. ATTACH <br />TO EACH END TRACK W/(1) #10 <br />SCREW PER FLANGE. <br />600T125-54 TYP. W/ (1) #10 <br />SCREW EA. FLANGE <br />CEILING <br />EXIST EXTERIOR CONC. <br />WALL <br />26 GA GALV. STEEL TRIM W/ <br />FINISH TO MATCH PANELS. <br />ATTACH TO PANELS W/ #10 x <br />3/4" S.M. SCREWS @ 12" O.C. <br />W/ PAINTED HEADS TO <br />MATCH PANELS <br />FOAM-IN-PLACE INSULATION <br />@ ALL GAPS <br />CONT. 4" x 4" x 10 GA W/ 3/8" <br />DIA./ X 4 3/8" LONG HILTI HIT-Z <br />ANCHOR ROD W/ HILTI HIT-HY <br />200-R V3 ADHESIVE W/ 2 3/8" <br />EMBEDMENT INTO EXISTING <br />CONCRETE PANEL @ 12" O.C. <br />(DO NOT CUT EXISTING <br />REINFORCEMENT) <br />SELF-ADHERING SHEET VAPOR <br />BARRIER (MIN. 3" COVERAGE) <br />INSULATED METAL WALL <br />PANEL (TYP.) <br />CONT. 12" X 10 GA PLATE W/(2) <br />3/8" DIA. X 4 3/8" LONG HILTI HIT- <br />Z ANCHOR ROD W/ HILTI HIT-HY <br />200-R V3 ADHESIVE W/ 2 3/8" <br />EMBEDMENT INTO EXISTING <br />CONCRETE PANEL @ 12" O.C. <br />(DO NOT CUT EXISTING <br />REINFORCEMENT) <br />CONT. SEALANT, <br />TYP. <br />4" <br />3" <br />4" <br />1" <br />NOTE: <br />1. APPLY CUT EDGE SEALANT TO ALL CUT <br />REINFORCED MEMBRANE EDGES. <br />2" <br />8" <br />2" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />2"5"2" <br />9" <br />1" PT PLYWOOD. ATTACHED TO <br />STEEL TUBE AND METAL STUDS <br />250S162-54 @ 12" O.C. <br />BETWEEN STEEL <br />TUBES. FILL W/ BATT <br />INSULATION TO IMP. <br />AIR/VAPOR BARRIER ON 1/2" <br />GWB. PROVIDE TRANSITION <br />MEMBRANE FROM PLYWOOD TO <br />GWB, AND GWB TO IMP. WRAP <br />TRANSITION MEMBRANE 2" ON <br />TOP OF PLYWOOD. <br />EIFS W/ DRAINAGE <br />PLANE <br />2" <br />GA <br />P <br />1" <br />1 1/2" <br />1" <br />2" <br />STEEL TUBE <br />TOP OF CORNICE <br />TRIM ENDS OF METAL <br />STUDS TO MATCH <br />SHAPE OF CORNICE <br />(4) #10 SCREWS @ 1 <br />1/2" SPACING EA. WAY <br />@ EA. LAP (TYP.) <br />1" <br />INSULATED METAL WALL <br />PANEL <br />ROOF MEMBRANE <br />HOT-AIR WELD <br />CONTINUOUS BONDING ADHESIVE <br />ROOF INSULATION <br />ALL FASTENERS THRU 1/8" <br />SEALANT TAPE <br />FIP INSULATION <br />FULLY ADHERED ROOF <br />MEMBRANE <br />2" SEAM PLATES @ 6" O.C. <br />1" RIGID INSULATION FULLY <br />ADHERED OR MECHANICALLY <br />FASTENED <br />CUT EDGE SEALANT <br />ADHERE ROOF FLASHING <br />MEMBRANE TO WALL CAP W/ <br />CONT. BONDING ADHESIVE <br />26 GA. GALV. STEEL CAP FLASHING <br />W/ FINISH TO MATCH PANEL <br />CONT. 22 GA. GALV. STEEL CLEAT <br />SET IN CONT. CAULKING TAPE <br />SLOPE <br />CONT 250T125-54 W/(1) <br />LINDAPTER TYPE HB <br />HEXAGONAL HEAD HOLLO- <br />BOLT (ESR-3300) @ 12" O.C. <br />CONT 250T125-54 W/(1) #10 SCREW @ 12" <br />OC TO METAL DECK <br />(1) #10 SCREW EA <br />FLANGE (TYP.) <br />250S162-54 @ 12" O.C. <br />CONT 2" X 2" X 16 GA <br />BENT PLATE W/(1) #10 <br />SCREW EA LEG TO <br />EA. STUD (TYP.) <br />CONT 2" X 2" X 16 GA <br />BENT PLATE W/(1) #10 <br />SCREW EA LEG TO <br />EA. STUD (TYP.) <br />PROVIDE (1) #10 SCREW EA. LEG TO EA. <br />STUD (TYP.) <br />CONDENSER <br />(BOLT TO STEEL BEAM) <br />STEEL BEAM - SEE <br />STRUCTURAL CONTRACT <br />DOCUMENTSMEMBRANE FLASHING <br />METAL CAP FLASHING <br />2" SEAM PLATES @ 6" O.C. <br />(TYP. BOTH SIDES) <br />1/8" X 3" BUTYL TAPE @ EACH <br />FASTENER <br />METAL ROOF DECK <br />ROOF INSULATION <br />(2) LAYERS OF 1 1/2" INSULATION <br />HOT-AIR WELD ROOF MEMBRANE <br />CONT. 2X PT WOOD BLOCKING <br />W/ 1/4" ROUTED EDGES <br />FOAM-IN-PLACE <br />INSULATION @ ALL GAPS <br />EXIST METAL DECK <br />EXIST EXT. CONC. WALL <br />FULLY ADHERED <br />ROOF MEMBRANE <br />HOT-AIR WELD <br />2" SEAM PLATES @ 6" O.C. <br />COMPRESSIBLE INSULATION <br />SPONGE TUBE DIAMETER TO <br />EXCEED OPENING BY >50% <br />ROOF INSULATION <br />METAL ROOF DECK <br />RETAINER TO BE BREATHABLE <br />FABRIC SUCH AS TYVEK OR <br />APPROVED EQUAL - FULLY ADHERED <br />AT CONC. WALL & WD. BLOCKING <br />STEEL BEAM <br />6" <br />2X WOOD BLOCKING. ATTACH TO TOP <br />OF EXIST. CONC. WALL W/ 3/8" DIA <br />GALV.HILTI HIT-Z X 4 3/8" LONG ANCHOR <br />ROD W/ HILTI HIT-HY200-R V3 ADHESIVE <br />W/ 2 3/8" EMBEDMENT@ 18" O.C. (DO <br />NOT CUT EXISTING REINFORCEMENT) <br />FLASHING MEMBRANE COMPATIBLE <br />W/ EXIST ROOF. SEAL TO EXT. <br />G.W.B. & ROOF MEMBRANE. <br />EXIST METAL DECK <br />5/8" EXT. G.W.B. <br />FLASHING MEMBRANE, HOT AIR <br />WELDED TO METAL TRANSITION <br />EXIST EXT. CONC. WALL <br />CONT. SEALANT (TYP.) <br />(2) CONT. BEADS OF SIKAFLEX 1A SEALANT, <br />OR COMPATIBLE ROOF SEALANT <br />TPO COATED METAL TRANSITION STRIP. <br />SECURE TO BLOCKING AT 4" O.C. <br />STAGGERED. SET IN FULL BED OF WATER <br />BLOCK MASTIC. SNAP TO COMPATIBLE <br />FLASHING MEMBRANE <br />ROOF MEMBRANE AND INSULATION <br />TO MATCH EXISTING IN TYPE, <br />THICKNESS AND SLOPE, AS REQ. <br />SEAL ROOF MEMBRANE TO EXIST <br />MEMBRANE PER MANUFACTURERS <br />STANDARD DETAIL <br />EXIST ROOF MEMBRANE <br />ATTACH ROOF MEMBRANE TO EXIST <br />CONC. WALL AS REQ. BY MANUFACTURER <br />REMOVE EXIST PARAPET <br />AND CORNICE AS INDICATE <br />FOR NEW WORK. <br />DEMO NEW WORK <br />E.J. <br />6" <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />B-402-1 <br />RBF <br />EJE <br />04/02/2024 <br />DETAILS ROOF <br />2350 PULLMAN ASPIRE BAKERY <br />2350 PULLMAN STREET <br />SANTA ANA, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />PULLMAN,LLC <br /> 3" = 1'-0"B-402-1 <br />A IMP PARAPET <br /> 1 1/2" = 1'-0"B-402-1 <br />C ROOF @ EXIST CONC PARAPET HIGH <br /> 1 1/2" = 1'-0"B-402-1 <br />B ROOF @ EXIST CONC PARAPET LOW <br /> 1 1/2" = 1'-0"B-402-1 <br />D DOCK CANOPY <br /> 3" = 1'-0"B-402-1 <br />E DOCK CANOPY - FLASHING <br /> 3" = 1'-0"B-402-1 <br />F DOCK CANOPY- PENETRATION <br /> 3" = 1'-0"B-402-1 <br />G DOCK CANOPY - GUTTER <br /> 1 1/2" = 1'-0"B-402-1 <br />L IMP @ CONC. WALL HEAD <br /> 3" = 1'-0"B-402-1 <br />H IMP PARAPET W/ EIFS CORNICE 1 1/2" = 1'-0"B-402-1 <br />J ROOF @ REMOVED PARAPET <br />NO.DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />B 01/07/2025 BULLETIN #5R1 - PHASE 1 <br /> 1 1/2" = 1'-0"B-402-1 <br />K CONDENSER SUPPORT <br />B <br />01- <br />REGISTERED PROFESSIONAL ENGINEER67268RICHARD MAURICE THIBEAULT <br />STATE OF CALIFORNIACIVIL <br />1/7/25 <br />2350 S Pullman St - <br />Phase I3/4/2025
The URL can be used to link to this page
Your browser does not support the video tag.