Laserfiche WebLink
ESR-4266 <br />■ 1 Y iA it li.... v��w.,.. n.........w ..w r.......w 1 <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />Page 3 of 18 <br />( !I nano <br />Nn f,' — Np•uncr lz,soo) (lb, psi) (Eq-2) <br />fl nuncr <br />Np,f,' — Npu ncr ( `) (N, MPa) <br />17.2 <br />Approved <br />FOR PERMIT ISSUANCE <br />Where values for No, or Np.uncr are not provided in Table 4 or Table 5, the pullout stre d*ki% ikon need <br />not be evaluated. Date: <br />The nominal pullout strength in cracked concrete of the carbon steel KB-TZ2 inst�llarl in the soffit of <br />sand -lightweight or normal -weight concrete on steel deck floor and roof assemblies, as shown in Figure 5A, <br />Figure 5B and Figure 5C, is given in Table 8. In accordance with ACI 318-19 17.6.3.2.1 the nominal pullout <br />strength in cracked concrete must be calculated in accordance with Eq-1, whereby the value of Nodrck.cr must <br />be substituted for Np.,, and the value of 3,000 psi (20.7 MPa) must be substituted for the value of 2,500 psi <br />(17.2 MPa) in the denominator. In regions where analysis indicates no cracking in accordance with ACI 318- <br />19 17.6.3.3 the nominal strength in uncracked concrete must be calculated according to Eq-2, whereby the <br />value of Np.deck.uncr must be substituted for Np.,,,,c,and the value of 3,000 psi (20.7 MPa) must be substituted for <br />the value of 2,500 psi (17.2 MPa) in the denominator. The use of stainless steel KB-TZ2 anchors installed in <br />the soffit of concrete on steel deck assemblies is beyond the scope of this report. <br />4.1.5 Requirements for Static Steel Strength in Shear: The nominal steel strength in shear, V,, of a single <br />anchor in accordance with ACI 318-19 17.7.1.2 is given in Table 6 and Table 7 of this report and must be used <br />in lieu of the values derived by calculation from ACI 318-19 Eq. 17.7.1.2b. The shear strength Vsa.deck of the <br />carbon -steel KB-TZ2 as governed by steel failure of the KB-TZ2 installed in the soffit of sand -lightweight or <br />normal -weight concrete on steel deck floor and roof assemblies, as shown in Figure 5A, Figure 5B and Figure <br />5C, is given in Table 8. <br />4.1.6 Requirements for Static Concrete Breakout Strength in Shear: The nominal concrete breakout <br />strength of a single anchor or group of anchors in shear, Vcb or V,b9, respectively, must be calculated in <br />accordance with ACI 318-19 17.7.2 with modifications as described in this section. The basic concrete breakout <br />strength, Vb, must be calculated in accordance with ACI 318-19 17.7.2.2.1 based on the values provided in <br />Table 6 and Table 7. The value of G used in ACI 318-19 Eq. 17.7.2.2.1a must be taken as no greater than the <br />lesser of ho or 8da. Anchors installed in light -weight concrete must use the reduction factors provided in ACI <br />318-19 17.2.4. <br />For carbon steel KB-TZ2 anchors installed in the soffit of sand -lightweight or normal -weight concrete on steel <br />deck floor and roof assemblies, as shown in Figure 5A, Figure 5B and Figure 5C, calculation of the concrete <br />breakout strength in shear is not required. <br />4.1.7 Requirements for Static Concrete Pryout Strength in Shear: The nominal concrete pryout strength <br />of a single anchor or group of anchors, Vcp or Vcpg, respectively, must be calculated in accordance with ACI <br />318-19 17.7.3 modified by using the value of kip provided in Table 6 and Table 7 of this report and the value <br />of N.b or Nlb� as calculated in Section 4.1.3 of this report. <br />For carbon steel KB-TZ2 anchors installed in the soffit of sand -lightweight or normal -weight concrete over <br />profile steel deck floor and roof assemblies, as shown in Figure 5A, Figure 513 and Figure 5C, calculation of <br />the concrete pry -out strength in accordance with ACI 318-19 17.7.3 is not required. <br />4.1.8 Requirements for Seismic Design: <br />4.1.8.1 General: For load combinations including seismic, the design must be performed in accordance with <br />ACI 318-19 17.10. Modifications to ACI 318-19 17.10 shall be applied under Section 1905.7 of the 2024 IBC. <br />The anchors comply with ACI 318-19 2.3, as ductile steel elements and must be designed in accordance <br />with ACI 318-19 17.10.5, 17.10.6, 17.10.7 or 17.10.4. Strength reduction factors, ¢, are given in Table 4, Table <br />5, Table 6 and Table 7 of this report. The anchors may be installed in structures assigned to Seismic Design <br />Categories A through F of the IBC. <br />4.1.8.2 Seismic Tension: The nominal steel strength and nominal concrete breakout strength for anchors <br />in tension must be calculated in accordance with ACI 318-19 17.6.1 and 17.6.2 as described in Sections 4.1.2 <br />and 4.1.3 of this report. In accordance with ACI 318-19 17.6.3.2.1 the appropriate pullout strength in tension <br />for seismic loads, Np,q, described in Table 4 and Table 5 or Np deck.cr described in Table 8 must be used in lieu <br />of Np, as applicable. The value of Np,4 or NP.d,ck.cr may be adjusted by calculation for concrete strength in <br />accordance with Eq-1 and Section 4.1.4 whereby the value of Nodack.cr must be substituted for Np.c,and the <br />value of 3,000 psi (20.7 MPa) must be substituted for the value of 2,500 psi (17.2 MPa) in the denominator. If <br />no values for Np.Nv or NP.dl:ce._q are given in Table 4, Table 5, or Table 8, the static design strength values govern. <br />