Laserfiche WebLink
ESR-4266 <br />UffaMust Widely Accepted and Pis red <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />Page 5 of 18 <br />Conversion factor calculated as a weighted average of the load fact rs for the`ctM�lrr9ved <br />load combination. In addition, a must include all applicable fa orkCt�-RR&i MIfbrISSUANCE <br />nonductile failure modes and required over -strength - <br />The requirements for member thickness, edge distance and spacing, described in this r port, must apply. <br />Master I- <br />4.2.2 Interaction of Tensile and Shear Forces: The interaction must be calculated an onslstengwith ACI <br />318-19 17.8 as follows: ate: <br />For shear loads Vappl,ed 5 0.2Va11cwab1e,ASD, the full allowable load in tension is permitted. <br />For tension loads TappDed 5 0.2Ta11owab1e.ASD, the full allowable load in shear is permitted. <br />For all other cases: <br />Tapplied + Vapplied 51.2 (Eq-4) <br />TallowableASD Vallowable.ASD <br />4.2.3 Installation: <br />Installation parameters are provided in Table 1 and Figure 2, Figure 5A, Figure 5B, Figure 5C and Figure 5D. <br />Anchor locations must comply with this report and plans and specifications approved by the code official. The <br />Hilti KB-TZ2 must be installed in accordance with manufacturer's published instructions and this report. In case <br />of conflict, this report governs. Anchors must be installed in holes drilled into the concrete using carbide -tipped <br />masonry drill bits complying with ANSI B212.15-1994, using the Hilti SafeSet System" with Hilti TE-YD or <br />TE-CD Hollow Drill Bits complying with ANSI B212.15-1994 with a Hilti vacuum in accordance with Figure 6 <br />and Figure 7, or using Hilti SPX-T core bits in accordance with Figure 7. The Hollow Drill Bits are not permitted <br />for use with the '/.-inch and 3/8-inch diameter KB-TZ2 anchors. The Hilti SPX-T core bits are not permitted for <br />use with the '/a -inch and 1-inch diameter KB-TZ2 anchors. The minimum drilled hole depth, ho, is given in <br />Table 1. If dust and debris is removed from the drilled hole with the Hilti TE-YD or TE-CD Hollow Drill Bits, the <br />DRS attachment system, or compressed air or a manual pump, hnem is achieved at the specified value of <br />ho noted in Table 1. The anchor must be hammered into the predrilled hole until hno,;, is achieved. The nut must <br />be tightened against the washer until the torque values specified in Table 1 are achieved, or the anchors may <br />be installed using the appropriate Hilti Impact Wrench and corresponding Hilti AT Module in accordance with <br />Figure 7. The Hilti AT Tool system is not permitted for use with the '/a -inch and 1-inch diameter KB-TZ2 <br />anchors. For installation in the soffit of concrete on steel deck assemblies, the hole diameter in the steel deck <br />must not exceed the diameter of the hole in the concrete by more than '/e inch (3.2 mm). For member thickness <br />and edge distance restrictions for installations into the soffit of concrete on steel deck assemblies, Figure, <br />Figure 5B and Figure 5C. <br />4.3 Special Inspection: <br />Periodic special inspection is required in accordance with Section 1705.1.1 and Table 1705.3 of the 2024 IBC, <br />as applicable. The special inspector must make periodic inspections during anchor installation to verify anchor <br />type, anchor dimensions, concrete type, concrete compressive strength, anchor spacing, edge distances, <br />concrete member thickness, tightening torque, hole dimensions, anchor embedment and adherence to the <br />manufacturer's printed installation instructions. The special inspector must be present as often as required in <br />accordance with the "statement of special inspection." Under the IBC, additional requirements as set forth in <br />Sections 1705, 1706 and 1707 must be observed, where applicable. <br />5.0 CONDITIONS OF USE: <br />The Hilti KB-TZ2 anchors described in this report comply with the codes listed in Section 1.0 of this report, subject <br />to the following conditions: <br />5.1 Anchor sizes, dimensions, minimum embedment depths and other installation parameters as set forth in <br />this report. <br />5.2 The anchors must be installed in accordance with the manufacturer's published instructions and this report. <br />In case of conflict, this report governs. <br />5.3 Anchors must be limited to use in cracked and uncracked normal -weight concrete and lightweight concrete <br />having a specified compressive strength, fc, of 2,500 psi to 8,500 psi (17.2 MPa to 58.6 MPa), and cracked <br />and uncracked normal -weight or sand -lightweight concrete over metal deck having a specified compressive <br />strength, fc, of 3,000 psi to 8,500 psi (20.7 MPa to 58.6 MPa). <br />5.4 The values of f,; used for calculation purposes must not exceed 8,000 psi (55.1 MPa). <br />5.5 The concrete shall have attained its minimum design strength prior to installation of the anchors. <br />5.6 Strength design values must be established in accordance with Section 4.1 of this report. <br />