ESR-4266
<br />l'fcsr widely Accewed and 7rusre^-
<br />CITY OF SANTA ANA
<br />Planning and Building Agency
<br />Page TO of 18
<br />TABLE 5-HILTI STAINLESS STEEL KB-TZ2 DESIGN INFORMATION FOR HAMMER AND
<br />INSTALLATIONS,TENSION"
<br />DRILLED Approved
<br />FOR PERMIT ISSUANCE
<br />Design parameter
<br />Symbol
<br />Units
<br />Nominal anchor diameter (in)
<br />1/4
<br />3/8
<br />1/2
<br />5/8
<br />3/4
<br />Effective min embedment'
<br />h.,
<br />in
<br />1-1/2
<br />1.1/2
<br />2
<br />2-1/2
<br />2
<br />2-1/2
<br />3-1/4
<br />2-3/4
<br />3.1/4
<br />1
<br />4
<br />j
<br />3-1/4
<br />MA-
<br />>a�f
<br />mm)
<br />(38)
<br />(38)
<br />(51)
<br />(64)
<br />(51)
<br />(64)
<br />(83)
<br />(70)
<br />1 (83)
<br />(102)
<br />(83)
<br />(t21)
<br />(102;
<br />1146)
<br />Tension, steel failure modes
<br />Strength reduction factor for
<br />steel in tension''
<br />mw ,
<br />-
<br />0.75
<br />075
<br />075
<br />0.75
<br />0.75
<br />0.75
<br />Min. specified yield strength
<br />/,
<br />lb/in'
<br />100.900
<br />96,300
<br />96,300
<br />91.600
<br />84.100
<br />65.000
<br />(N/mm2)
<br />(696)
<br />(664)
<br />(664)
<br />(632)
<br />(580)
<br />(448)
<br />Min. specified ult. strength
<br />1,,:,
<br />Ib/in'
<br />122,400
<br />120.100
<br />120,400
<br />114.600
<br />100.500
<br />99.900
<br />(N/mm')
<br />(15")
<br />(828)
<br />(830)
<br />(790)
<br />(693)
<br />(689)
<br />Effective tensile stress area
<br />A„„
<br />In'
<br />0 024
<br />0.051
<br />0 099
<br />0 164
<br />0.239
<br />0.470
<br />(mm')
<br />(15.4)
<br />(33.2)
<br />(63.6)
<br />(106.0)
<br />(154.4)
<br />(303 2)
<br />Steel strength in tension
<br />N,,,
<br />lb
<br />2,920
<br />6.180
<br />11,870
<br />18,835
<br />24,045
<br />46.955
<br />(kN)
<br />(13.0)
<br />(27.5)
<br />(52,8)
<br />(83.8)
<br />(107.0)
<br />(208.9)
<br />Tension, concrete failure modes
<br />Anchor category
<br />3
<br />1
<br />1
<br />1
<br />1
<br />1
<br />Strength reduction factor for
<br />concrete and pullout failure
<br />in tension, (Condition B -
<br />m.,, m: v
<br />0 45
<br />065
<br />065
<br />0,65
<br />065
<br />0,65
<br />supplementary
<br />reinforcement not present)'
<br />Effectiveness factor for
<br />uncracked concrete
<br />k
<br />24
<br />24
<br />24
<br />24
<br />24
<br />276
<br />24
<br />27
<br />Effectiveness factor for
<br />cracked concrete
<br />k�
<br />17
<br />21
<br />17
<br />17
<br />21
<br />17
<br />21
<br />17
<br />21
<br />216
<br />21
<br />24
<br />21
<br />Modification factor for
<br />anchor resistance, tension.
<br />W"N
<br />-
<br />1.0
<br />1.0
<br />1.0
<br />1 0
<br />1.0
<br />1.0
<br />uncracked concrete
<br />n.
<br />4
<br />4-1i2
<br />5-1/2
<br />4-V8
<br />5-112
<br />6-1/4
<br />7-1i2
<br />10
<br />6-1i2
<br />8-3/4
<br />12
<br />10
<br />10
<br />11
<br />15-112
<br />Critical edge distance
<br />c
<br />(mm)
<br />(102)
<br />(114)
<br />(140)
<br />(105)
<br />(140)
<br />(159)
<br />(191) 1
<br />(254)
<br />(165)
<br />(222)
<br />(305)
<br />(254)
<br />(254)
<br />(279)
<br />(394)
<br />Pullout strength uncracked
<br />lb
<br />1.570
<br />4.185
<br />3,380
<br />4.010
<br />5.500
<br />4.085
<br />6,015
<br />8,050
<br />concretes
<br />/-
<br />WA
<br />N1A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />(kN)
<br />(7.0)
<br />(18.6)
<br />(15.0)
<br />(17.8)
<br />(24.5)
<br />(18.2)
<br />(26.8)
<br />(35.8)
<br />Pullout strength cracked
<br />lb
<br />670
<br />8,795
<br />concretes
<br />J-
<br />N/A
<br />NiA
<br />N/A
<br />NIA
<br />N/A
<br />N/A'
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />NIA
<br />(kN)
<br />(3.0)
<br />(39.1)
<br />Pullout strength
<br />Ib
<br />670
<br />8,795
<br />seismic'
<br />N, ro
<br />N/A
<br />NIA
<br />NIA
<br />N/A
<br />N/A
<br />N/A'
<br />N/A
<br />NIA
<br />WA
<br />N/A
<br />N/A
<br />N/A
<br />N/A
<br />(kN)
<br />(3.0)
<br />(39.1)
<br />Normalization (actor,
<br />uncracked concrete
<br />n
<br />0,39
<br />N/A
<br />N,,A
<br />0.37
<br />0.46
<br />0.50
<br />0,50
<br />0.50
<br />0.42
<br />0.47
<br />N/A
<br />N/A
<br />0.30
<br />N/A
<br />N/A
<br />Normalization factor,
<br />cracked concrete. seismic
<br />n...
<br />0 50
<br />N/A
<br />N;A
<br />N/A
<br />NIA T
<br />NIA
<br />0 50
<br />N/A
<br />N/A
<br />WA
<br />NIA
<br />NIA
<br />050
<br />N/A
<br />N/A
<br />Tension, axial stiffness
<br />Axial st;ffness in service
<br />/i nn
<br />Ib/in.
<br />166,490
<br />175,800 1
<br />137.145
<br />153,925
<br />342.680
<br />105.970
<br />load range
<br />Win.
<br />33,805 1
<br />79.860 1
<br />97,985
<br />69,625
<br />75,715
<br />117.630
<br />For SI: 1 inch = 25.4 mm. 1 Ibf = 4.45 N. 1 psi = 0.006895 MPa For pound -inch units: 1 mm = 0.03937 inches.
<br />Figure 2 of this report illustrates the installation parameters.
<br />' The KB-TZ2 is considered a ductile steel element in accordance with ACI 318-19 2.3.
<br />The strength reduction 'actor applies when the load combinations from the IBC or ACI 318 are used and the requirements of ACI 318-19 17.5.3 are met The strength
<br />reduction factors are applicable with supplementary reinforcement is not present. Greater strength reduction factors may be used in areas where supplementary
<br />reinforcement can be verified.
<br />' For all design cases, W, = 1.0. The appropriate effectiveness factor for cracked concrete (kc) or uncracked concrete (k, _) must be used.
<br />s For all design cases, W:,v = 1.0. Tabular value for pullout strength is for a concrete compressive strength of 2,500 psi (17.2 MPa). Pullout strength for concrete
<br />compressive strength greater than 2,500 psi (17.2 MPa) may be increased by multiplying the tabular pullout strength by (Pc / 2,500)" for psi, or (fc / 17.2)" for MPa,
<br />where n is given as n,- for uncracked concrete and n , for cracked concrete NA (not applicable) denotes that pullout strength does not need to be considered for
<br />design.
<br />' For core drill installations, K_ = 24 and k„ = 17 for'/4-inch diameter anchors installed at 31/4 inches (95 mm) effective embedment.
<br />For core drill installations, N,,, = 4245 lb (18.9 kN) and N,. = 42451b (18.9 kN) for '/rinch diameter anchors installed at 3'/, inches (83 mm) effective embedment.
<br />"/,-inch and 1-Inch diameter anchors are not permitted for core drilling installations.
<br />
|