Laserfiche WebLink
ESR-4266 <br />l'fcsr widely Accewed and 7rusre^- <br />CITY OF SANTA ANA <br />Planning and Building Agency <br />Page TO of 18 <br />TABLE 5-HILTI STAINLESS STEEL KB-TZ2 DESIGN INFORMATION FOR HAMMER AND <br />INSTALLATIONS,TENSION" <br />DRILLED Approved <br />FOR PERMIT ISSUANCE <br />Design parameter <br />Symbol <br />Units <br />Nominal anchor diameter (in) <br />1/4 <br />3/8 <br />1/2 <br />5/8 <br />3/4 <br />Effective min embedment' <br />h., <br />in <br />1-1/2 <br />1.1/2 <br />2 <br />2-1/2 <br />2 <br />2-1/2 <br />3-1/4 <br />2-3/4 <br />3.1/4 <br />1 <br />4 <br />j <br />3-1/4 <br />MA- <br />>a�f <br />mm) <br />(38) <br />(38) <br />(51) <br />(64) <br />(51) <br />(64) <br />(83) <br />(70) <br />1 (83) <br />(102) <br />(83) <br />(t21) <br />(102; <br />1146) <br />Tension, steel failure modes <br />Strength reduction factor for <br />steel in tension'' <br />mw , <br />- <br />0.75 <br />075 <br />075 <br />0.75 <br />0.75 <br />0.75 <br />Min. specified yield strength <br />/, <br />lb/in' <br />100.900 <br />96,300 <br />96,300 <br />91.600 <br />84.100 <br />65.000 <br />(N/mm2) <br />(696) <br />(664) <br />(664) <br />(632) <br />(580) <br />(448) <br />Min. specified ult. strength <br />1,,:, <br />Ib/in' <br />122,400 <br />120.100 <br />120,400 <br />114.600 <br />100.500 <br />99.900 <br />(N/mm') <br />(15") <br />(828) <br />(830) <br />(790) <br />(693) <br />(689) <br />Effective tensile stress area <br />A„„ <br />In' <br />0 024 <br />0.051 <br />0 099 <br />0 164 <br />0.239 <br />0.470 <br />(mm') <br />(15.4) <br />(33.2) <br />(63.6) <br />(106.0) <br />(154.4) <br />(303 2) <br />Steel strength in tension <br />N,,, <br />lb <br />2,920 <br />6.180 <br />11,870 <br />18,835 <br />24,045 <br />46.955 <br />(kN) <br />(13.0) <br />(27.5) <br />(52,8) <br />(83.8) <br />(107.0) <br />(208.9) <br />Tension, concrete failure modes <br />Anchor category <br />3 <br />1 <br />1 <br />1 <br />1 <br />1 <br />Strength reduction factor for <br />concrete and pullout failure <br />in tension, (Condition B - <br />m.,, m: v <br />0 45 <br />065 <br />065 <br />0,65 <br />065 <br />0,65 <br />supplementary <br />reinforcement not present)' <br />Effectiveness factor for <br />uncracked concrete <br />k <br />24 <br />24 <br />24 <br />24 <br />24 <br />276 <br />24 <br />27 <br />Effectiveness factor for <br />cracked concrete <br />k� <br />17 <br />21 <br />17 <br />17 <br />21 <br />17 <br />21 <br />17 <br />21 <br />216 <br />21 <br />24 <br />21 <br />Modification factor for <br />anchor resistance, tension. <br />W"N <br />- <br />1.0 <br />1.0 <br />1.0 <br />1 0 <br />1.0 <br />1.0 <br />uncracked concrete <br />n. <br />4 <br />4-1i2 <br />5-1/2 <br />4-V8 <br />5-112 <br />6-1/4 <br />7-1i2 <br />10 <br />6-1i2 <br />8-3/4 <br />12 <br />10 <br />10 <br />11 <br />15-112 <br />Critical edge distance <br />c­ <br />(mm) <br />(102) <br />(114) <br />(140) <br />(105) <br />(140) <br />(159) <br />(191) 1 <br />(254) <br />(165) <br />(222) <br />(305) <br />(254) <br />(254) <br />(279) <br />(394) <br />Pullout strength uncracked <br />lb <br />1.570 <br />4.185 <br />3,380 <br />4.010 <br />5.500 <br />4.085 <br />6,015 <br />8,050 <br />concretes <br />/- <br />WA <br />N1A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />(kN) <br />(7.0) <br />(18.6) <br />(15.0) <br />(17.8) <br />(24.5) <br />(18.2) <br />(26.8) <br />(35.8) <br />Pullout strength cracked <br />lb <br />670 <br />8,795 <br />concretes <br />J- <br />N/A <br />NiA <br />N/A <br />NIA <br />N/A <br />N/A' <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />NIA <br />(kN) <br />(3.0) <br />(39.1) <br />Pullout strength <br />Ib <br />670 <br />8,795 <br />seismic' <br />N, ro <br />N/A <br />NIA <br />NIA <br />N/A <br />N/A <br />N/A' <br />N/A <br />NIA <br />WA <br />N/A <br />N/A <br />N/A <br />N/A <br />(kN) <br />(3.0) <br />(39.1) <br />Normalization (actor, <br />uncracked concrete <br />n <br />0,39 <br />N/A <br />N,,A <br />0.37 <br />0.46 <br />0.50 <br />0,50 <br />0.50 <br />0.42 <br />0.47 <br />N/A <br />N/A <br />0.30 <br />N/A <br />N/A <br />Normalization factor, <br />cracked concrete. seismic <br />n... <br />0 50 <br />N/A <br />N;A <br />N/A <br />NIA T <br />NIA <br />0 50 <br />N/A <br />N/A <br />WA <br />NIA <br />NIA <br />050 <br />N/A <br />N/A <br />Tension, axial stiffness <br />Axial st;ffness in service <br />/i nn <br />Ib/in. <br />166,490 <br />175,800 1 <br />137.145 <br />153,925 <br />342.680 <br />105.970 <br />load range <br />Win. <br />33,805 1 <br />79.860 1 <br />97,985 <br />69,625 <br />75,715 <br />117.630 <br />For SI: 1 inch = 25.4 mm. 1 Ibf = 4.45 N. 1 psi = 0.006895 MPa For pound -inch units: 1 mm = 0.03937 inches. <br />Figure 2 of this report illustrates the installation parameters. <br />' The KB-TZ2 is considered a ductile steel element in accordance with ACI 318-19 2.3. <br />The strength reduction 'actor applies when the load combinations from the IBC or ACI 318 are used and the requirements of ACI 318-19 17.5.3 are met The strength <br />reduction factors are applicable with supplementary reinforcement is not present. Greater strength reduction factors may be used in areas where supplementary <br />reinforcement can be verified. <br />' For all design cases, W, = 1.0. The appropriate effectiveness factor for cracked concrete (kc) or uncracked concrete (k, _) must be used. <br />s For all design cases, W:,v = 1.0. Tabular value for pullout strength is for a concrete compressive strength of 2,500 psi (17.2 MPa). Pullout strength for concrete <br />compressive strength greater than 2,500 psi (17.2 MPa) may be increased by multiplying the tabular pullout strength by (Pc / 2,500)" for psi, or (fc / 17.2)" for MPa, <br />where n is given as n,- for uncracked concrete and n , for cracked concrete NA (not applicable) denotes that pullout strength does not need to be considered for <br />design. <br />' For core drill installations, K_ = 24 and k„ = 17 for'/4-inch diameter anchors installed at 31/4 inches (95 mm) effective embedment. <br />For core drill installations, N,,, = 4245 lb (18.9 kN) and N,. = 42451b (18.9 kN) for '/rinch diameter anchors installed at 3'/, inches (83 mm) effective embedment. <br />"/,-inch and 1-Inch diameter anchors are not permitted for core drilling installations. <br />