Complies with the 2021 International Building Code and AISI S100-16/S2-20 <br /> Style Web Depth <br />(in) <br />18Mil <br />0.0188 <br />27Mil <br />0.0283 <br />30Mil <br />0.0312 <br />33Mil <br />0.0346 <br />43Mil <br />0.0451 <br />54Mil <br />0.0566 <br />68Mil <br />0.0713 <br />97Mil <br />0.1017 <br />118Mil <br />0.1242 <br />162S 1.625 75 50 45 41 31 24 18 11 8 <br />250S 2.500 122 81 73 66 50 39 30 20 15 <br />350S 3.500 175 116 105 95 72 57 44 29 23 <br />362S 3.625 182 120 109 98 75 59 46 31 24 <br />400S 4.000 202 1 134 121 109 84 66 51 34 27 <br />550S 5.500 - 187 169 153 117 92 72 49 39 <br />600S 6.000 - 204 1 185 167 128 101 79 54 43 <br />800S 8.000 - - 249 1 225 1 172 136 107 74 59 <br />1000S 10.000 - - - - 207 1 172 135 93 76 <br />1200S 12.000 - - - - - 207 163 113 92 <br />1400S 14.000 - - - - - 242 1 191 133 108 <br />1600S 16.000 - - - - - - 219 1 152 124 <br />1 h/t exceeds 200 <br />2 h value used for h/t calculations is the ß at width of the web. For Stud members, this is the out-to-out member size, minus twice the thickness, minus twice the inside bend radius. <br />3 h/t values exceeding 260 are marked with a dash ( - ) <br />Member h/t Member h/t <br />400Sxxx18 202 1000xxx43 217 <br />600Sxxx27 204 1200Sxxx54 207 <br />800Sxxx30 249 1400Sxxx54 242 <br />800Sxxx33 225 1600Sxxx68 219