Laserfiche WebLink
135 SIGN COMPONENTS MANUAL (SAM)October 1,2013 <br />2. Theload powered,by theiCIass 2 output of the power supplies rated at max 30 VDC or less are suitable for use in dry, damp and <br />wet locations. <br />3. In the end product. power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewails, <br />and minimum 2 inches spacing to top of enclosure. <br />4. These, prof!9Rtiareerovided-fve following electrical ratings: <br />Input - _Output <br /> Model .Vac A Hz Vdc A 01 <br />701680-MW 100-240 0.55 50/60 12 1.67 1 <br />5. These products shall be enclosed in the end product. <br />6 These power supplies are suitable for use in dry and damp locations. <br />Class 2 power supply, Model 701681. <br />1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate <br />application. <br />2. These units are provided with a Class 105(A) insulation system. <br />3 Input leads are Style 1015, No. 18 AWG, rated VW-1,600 V, 105'C. Output leads are Style 1430, No. 18 AWG„rated VW-1, <br />300 V, 105'C. The suitability of the input and output connections shall be determined ih each end use application. <br />4. These power units are intended for dry or damp location use only. <br />5. Strain Relief and Impact Tests have not been investigated on input lead construdtion. The suitability of the enclosure as ultimate <br />enclosure shall be determined in the end-use application. <br />6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of the polymeric enclosure <br />is V-0 and the necessity of additional fire barriers shall be determined in end product. <br />7. In the end product. power supply spacing to other heat producing components shall be minimum i2 inches spacing to,sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Class 2 power supplies. Model 701495. <br />1. These power supplies have been evaluated te Class 2 output requirements for dc circuits with a rriaximum of four Class 2 <br />outputs. <br />2. These power supplies are only suitable for use in dry, damp and wet locations. <br />3. ln the end product, power supply spacing to other heat producing components shall be minimum 2 ihches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Class 2 power LED Lighting Strip, 701912-QQXXYYZZZ series, where QQ represents length, XX represents tbe LED color <br />temperature, YY represents configuration and ZZZ represents the LED drive current. <br />1. These products are only suitable for connection to a Class 2 power source, rated 24VDC. <br />2. These products have not been evaluated for use when connected td a power source thatdoes not comply with Class 2 voltage <br />and energy limits and which is rated greater than 24VDC. <br />3. VVhen units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated class 2. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means available. <br />7. When these products are used in applications other than signs or outlihe lighting, the need to conduct a temperature test shall <br />be considered. <br />Class 2 "Dimming Control Knob" potentiorneter, Model 701843. <br />1. These products are only suitable for connection to the output of a UL Listed or Recoghized Class 2 power supply rated max 12 <br />VDC. <br />2. These products are suitable for use in dry and damp locations. <br />3. These products are suitable for factory wiring only. <br />4. These products are 1 Kohm potentiometers intended for connection to max 12 VDC Class 2 power supply that drops the voltage <br />to a 0-10 V signal to feed into the PWM dimmer. <br />Class 2 LED Modules, Cat. No. 701960-XXYYYZ Series, where XX, YYY, and Z may be replaced with any alphanumeric <br />character or blank. <br />1. These products are suitable for use in dry, damp and wet locations and supplied only with a Class 2 power source irated 24 Volt <br />DC or less. <br />2. When units are connected to a Class 2 circuit, they are not t0 draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />3. These products are not required to be enclosed or protected from the weather in the end product. <br />4. These products may be secured in place in the end product by any means available. <br />Class 2 power supplies, Models 701507-60W1 -JV and 701507-60W1-CT. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 <br />output. <br />2. These products are provided with the following electrical ratings: <br />Output Output <br />Frequency Voltage Current <br />Model Number Input Voltage M Input Current (A)(Hz)¢Vdc)(mA) <br />701507-60W1 -JV,100-240 0.85 50/60 12 0-500 <br />701507-60W1-CT <br />3. In the end product, power supply spacing to other'heat producing components shall be at least 25.4 mm (1 in) from end to end <br />and 101.6 mm (4 in) from side to side. <br />4. These products shall be enclosed in the end product. <br />5. These products are suitable for factory wiring only. <br />6. These products are intended for use in a dry oridamp locations only. <br />7. The suitability of input/output leads and the wring shall be determined in end product use. <br />SPARTECH PLASTICS E202184