Laserfiche WebLink
(N) SOLAR CANOPY <br />STRUCTURAL COLUMN <br />LEGEND <br />ATTIC VENT <br />FLUSH ATTIC VENT <br />PVC PIPE VENT <br />SATELLITE DISH <br />T-VENT <br />CHIMNEY <br />FIRE SETBACKS <br />METAL PIPE VENT <br />HARDSCAPE <br />PROPERTY LINEPL <br />CLAMPING ZONES <br />RAIL <br />STANDOFFS & <br />FOOTINGS <br />SOLAR MODULES <br />XX## <br />TL: ##° AZ: ###° <br />ROOF IDENTIFIER <br />MOUNTING INDEX <br />MOUNTING TYPE <br />TILT <br />AZUMUTH <br />DOWN SLOPE <br />FLUSH FOOTING <br />RAIL <br />PITCH2° <br />CARPORT FOOTING <br />QCELL NORTH AMERICA <br />Q.PEAK DUO BLK ML-G10+ <br />LANDSCAPE CLAMP ZONE <br />0.79" TO 7.87" <br />0.8 <br />18.9 <br />19.7 <br />QCELL NORTH AMERICA <br />Q.PEAK DUO BLK ML-G10+ <br />PORTRAIT CLAMP ZONE <br />0.79" TO 19.7" <br />0.8 <br />7.1 <br />7.9 <br />ROOF FRAMING <br />MAX DISTRIBUTED LOAD: 3 PSF <br />SNOW LOAD: 0 PSF <br />WIND SPEED: 96 MPH <br />LAG SCREWS: <br />5/16"x3.5": 2.5" MIN EMBEDMENT <br />NOTE: <br />INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND <br />SLOPED SPANS, AND NOTIFY E.O.R. OF ANY <br />DISCREPANCIES BEFORE PROCEEDING. <br />ADDITIONAL DETAILS <br />WINDZONES <br />RF01 <br />TL: 19° AZ: 0° <br />RF02 <br />TL: 19° AZ: 270° <br />RF03 <br />TL: 19° AZ: 180°RF04 <br />TL: 19° AZ: 90° <br />C:\USERS\THADDEUS.STEERMAN\DESKTOP\WORKING PROJECTS\1233 - TOWNSEND & RAITT I\3 VA - AHJ COMMENTS AND MOD SWAP\1233_TOWNSEND & RAITT I_CAD_V0\TOWNSEND & RAITT I.DWG <br />STRUCTURAL DETAIL <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />TOWNSEND & RAITT I <br />817 S TOWNSEND ST, <br />SANTA ANA, CA 92704, USA <br />APN:109-611-20 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL05/14/25 <br />AAHJ COMMENTS 08/08/25 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·31.16 kW DC <br />·22.8 kW AC <br />·29.035 CEC AC <br />ENERGY STORAGE: <br />·11.4 kW AC <br />·29.1 kWH <br />S200 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: FINS_PK <br />A <br />CONTRACT NUMBER: <br />3003197588 <br />PJT #: PROP-001233 <br />A <br />SCALE: 3/16" = 1'-0" <br />BLDG 821 DETAIL POI-1A <br />A <br />S300 <br />1'-2" <br />9' <br />- <br />6 <br />" <br />2' <br />- <br />3 <br />" <br />11 <br />' <br />1' <br />1' <br />- <br />4 <br />" <br />3' <br />- <br />9 <br />" <br />17'4' TYP 6' TYP <br />POI-1 ROOF SCHEDULE <br />BLDG LABEL RACKING TILT (DEG)AZIMUTH <br />(DEG) <br />BUILDING <br />HEIGHT (FT) <br />MODULE <br />COUNT <br />MODULE AREA (SQFT) KW DC <br />821 RF01 FLUSH 19°0°20 28 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]591.4 11.48 <br />821 RF02 FLUSH 19°270°20 4 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]84.5 1.64 <br />821 RF03 FLUSH 19°180°20 40 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]844.8 16.40 <br />821 RF04 FLUSH 19°90°20 4 Q.PEAK DUO BLK ML-G10.C+ 410 [DCC]84.5 1.64 <br />Totals 76 1605.2 31.2A <br />REVIEWED FOR STRUCTURAL <br />8/8/25