149 SIGN COMPONENTS MANUAL (SAM)October 1, 2013
<br />UP100S12W1 100-120 | 50/60 |125 |1.85 12 8.4 100
<br />3. These products shall be enclosed in the end product.
<br />4. In the end product, power supply shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less
<br />than 4 inches (102mm) apart when arranged otherwise.
<br />5. The unit is intended for being used in fixed signs.
<br />6. The input and output connections have been investigated for factory wiring only. The need for other consideration should be
<br />considered in end-use product.
<br />7. This product is intended to be used in the condition Variable Resister (VRI) set to 200-450 Ohm.
<br />8. The power supply has been temperature tested in a 40 °C ambient, where the maximum temperatures on the outer surface of
<br />the enclosure above Electrolytic Capacitors (Cl) reached 67.3 °C. The need for further evaluation of the internal components
<br />shall be considered if enclosure temperatures exceed this value when subjected to temperature testing in the end product.
<br />UNIVERSAL LIGHTING TECHNOLOGIES
<br />1430 WALL TRIANA HWY
<br />E315636
<br />MADISON, AL 35756
<br />LED Class 2 Modules, Cat. Nos. LEDP503)<-YY(@), LEDP510X-YYLEDP515>GYY(@), where (@) X can be R, A, G, B, O, NW,
<br />DL or YW, YY can be 8V or 12V.
<br />1. These products are only suitable for connection to a Class 2 power source, rated 12 Volt or less.
<br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage
<br />and energy limits and which is rated greater than 12 V.
<br />3. Class 2 LED modules when units are connected to a Class 2 circuit, are not to draw a total wattage of greater than the
<br />secondary or output rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Vor less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />LED Class 2 Modules, Cat. Nos. LMA-25R, LMA-25W, LMA-25B, LMA-25G, LMA-25VWV.
<br />1. These components are only suitable for connection to a UL Listed or R/C (UYMR2), Component - Sign Accessory Class 2 power
<br />supply.
<br />2. These components have not been evaluated for use when connected to a power source that does not comply with Class 2
<br />requirements.
<br />3. Lead wires are not Listed Class 2 cable. Therefore leads must be enclosed in a sign housing, wireway, raceway, or electrical
<br />enclosure.
<br />4. All models are suitable for use in dry, damp and wet locations.
<br />5. Lead wires (R/C) (AVLV2) rated 300 V minimum, 80°C minimum.
<br />LED Power Supply with Class 2 output, Model L12V60UNVM.
<br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a max. of one Class 2 output.
<br />2. The load powered by the Class 2 output of the power supplies rated at max 30 VDC or less are suitable for use in dry, damp and
<br />wet locations.
<br />3. In the end product, power supply spacing to other heat producing components shall be min. 2 inches spacing to sidewalls, and
<br />min. 2 inches spacing to top of enclosure.
<br />4. This oroduct is rated as follows:
<br />Input (ac)Output (dc)
<br />Model V A Hz V A
<br />L12V60UNVM 100-240 0.8 50/60 12 5.0
<br />277 0.3
<br />5. This product shall be enclosed in the end product.
<br />6. This power supply is suitable for use in dry and damp locations.
<br />7. These products are suitable for factory wiring only.
<br />LED Power Supply with Class 2 output, Models L12V60UNV-A and D12V60UNV-A.
<br />1. The power supply shall be installed in compliance with the applicable requirements of the end-product standard for, mounting,
<br />spacing, casualty and segregation.
<br />2. The maximum available output parameters were within the maximum allowable limits for Class 2, inherently limited as specified
<br />in the UL 1310, Standard for Class 2 Power Units and also in accordance with the Canadian Safety Standard CSA C22.2 No.
<br />223.
<br />3. The power supply was submitted and tested for a maximum manufacturer's recommended Tc location, should not exceed 69°C,
<br />in ambient of 40°C. If adjacent LED power supplies are spaced closer than 1 in. end to end or 4 in. side to side a temperature
<br />test shall be conducted in the end use product.
<br />4. Power Supply is intended for use in indoor Dry and Damp location only.
<br />5. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls,
<br />and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in
<br />any other direction.
<br />6. The input and output leads were not subjected to the strain relief test.
<br />7. The primary (Black-White) and the output (Red-Black) connection wires of the power supply are FUC (AVLV2/AVLV8), 18 AWG,
<br />90°C. The suitability of the leads shall be determined in the end-use application.
<br />LED Power Supply with Class 2 output, Models O24V100UNV-A, L24V100UNV-A
<br />1. The power supply shall be installed in compliance with the applicable requirements of the end-product standard for enclosure,
<br />mounting, spacing, casualty and segregation.
<br />2. The maximum available output parameters were within the maximum allowable limits for Class 2, inherently limited as specified
<br />in the
<br />UL 1310, Standard for Class 2 Power Units and also in accordance with the Canadian Safety Standard CSA C22.2 No. 223.
<br />3. The power supply was submitted and tested in an ambient of 40°C. When evaluated in the end use, the Tc location as indicated
<br />on the label should not exceed 67°C.
<br />Uk
|