Laserfiche WebLink
FIRST FLOOR <br />-119' - 10 1/2" <br />SECOND FLOOR <br />-107' - 10 1/2" <br />C D E F G H <br />ROOF-86' - 4 1/2" <br />201 202 203 <br />109 110 111 112 <br />T.O.CORNICE-84' - 8" <br />NEW DRIP CAP <br />AT PARAPET, <br />TYP. <br />FIRST FLOOR-119' - 10 1/2" <br />SECOND FLOOR-107' - 10 1/2" <br />12345678910 <br />ROOF-86' - 4 1/2" <br />113 <br />204 205 206 <br />115 <br />208207 <br />EXTERIOR LIGHT <br />TRASH ENCLOSURESTOREFRONT <br />ENTRY W/FRAME <br />PORTAL <br />T.O.CORNICE-84' - 8" <br />3'-0" SINGLE LEAF <br />HOLLOW METAL <br />DOOR, WITH CARD <br />READER <br />INFILL WALL TO <br />MATCH EXISTING <br />NEW DRIP CAP <br />AT PARAPET, <br />TYP. <br />1 <br />A8.5-2 TYP. <br />120-E <br />107 123B-E 103B-E <br />114-B <br />ST4-E <br />CARD <br />READER. TYP.1 <br />A8.6-1 <br />DOOR ACTUATOR. <br />PUSH BUTTON SET <br />AND CARD READER MARBLE AT LOW WALLS TO BE <br />REPLACED. REFER TO SHEET A8.8-5 <br />FOR ADDITIONAL INFORMATION ON <br />STONE REPLACEMENT <br />1 <br />A5.0-6 <br />5 <br />A5.0-6 <br />#022 <br />ASI <br />108-A <br />3 <br />A8.7-2 <br />4 <br />A8.7-2 <br />3 <br />A8.7-2 <br />FIRST FLOOR-119' - 10 1/2" <br />SECOND FLOOR-107' - 10 1/2" <br />1 2 3 4 5 6 7 8 9 10 <br />ROOF-86' - 4 1/2" <br />101 102 103 104 105 106 107 <br />T.O.CORNICE-84' - 8" <br />NEW DRIP CAP <br />AT PARAPET, <br />TYP. <br />1 <br />A8.5-2 TYP. <br />101 <br />9" <br />104-B <br />DOOR ACTUATOR. <br />PUSH BUTTON SET <br />AND CARD READER <br />108NEW STOREFRONT <br />TO MATCH EXISTING <br />4 <br />G1.2-8 <br />1 <br />A5.0-6 <br />5 <br />A5.0-6 <br />#003 <br />ASI <br />(N) INFILL WALL. FINISHES TO <br />MATCH (E) ADJACENT <br />CUSTOM SECURITY SCREEN <br />(N) OPENING <br />1 <br />A3.6-2 <br />2 <br />A3.6-2 <br />12' - 1"3' - 0"12' - 0" <br />6' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />NEW DRIP CAP <br />AT PARAPET, <br />TYP. <br />5 <br />A5.0-6 <br />FIRST FLOOR-119' - 10 1/2" <br />SECOND FLOOR-107' - 10 1/2" <br />CDEFGH <br />ROOF <br />-86' - 4 1/2" <br />EXTERIOR STOREFRONT <br />DOOR AND METAL CLAD <br />PORTAL <br />EXTERIOR LIGHTEXTERIOR <br />STOREFRONT DOOR <br />T.O.CORNICE <br />-84' - 8" <br />NEW DRIP CAP <br />AT PARAPET, <br />TYP. <br />SECURITY FENCE A2.5-9 <br />3 <br />1 <br />A8.5-2 TYP. <br />100 <br />118 <br />210 211 <br />116 <br />117 <br />103-I DOOR ACTUATOR. <br />PUSH BUTTON SET <br />AND CARD READER <br />209 <br />REINSTALL <br />(E) GATE <br /> 1/8" = 1'-0"2 WEST ELEVATION - NEW <br /> 1/8" = 1'-0"3 SOUTH ELEVATION - NEW <br /> 1/8" = 1'-0"4 NORTH ELEVATION - NEW <br /> 1/8" = 1'-0"5 PORTE-COCHERE - NEW <br /> 1/8" = 1'-0"1 EAST ELEVATION <br />ST <br />09-30-2025 <br />O <br />ARCHITECT <br />FOFCALE <br />REN. <br />AT ARN <br />NO. <br />SE <br />LICNE <br />C-27893 <br />D <br />T <br />EC <br />HIT <br />ARC <br />DAVID SCHNEE <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />F R A N CN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />N D E N VA <br />,N I N G <br />CRAE <br />TCEIT <br />S C <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />0718 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />SHEET NOTES <br />N <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />PERMIT SET 1ST ISSUANCE <br />BID SET <br />FINAL PERMIT/CONFORM SET <br />09/29/2023 <br />04/30/2024 <br />08/02/2024 <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />REV # DESCRIPTION DATE <br />1 BACKCHECK REV-1 03.01.2024 <br />2 CITY REVIEW REV-1 08.02.2024 <br />3 CITY REVIEW REV-2 10.18.2024 <br />4 CITY REVIEW REV-3 01.27.2025 <br />5 CITY REVIEW REV-4 04.07.2025 <br />6 CITY REVIEW REV-5 06.27.2025 <br /> <br />REVIEWED FOR CONSTRUCTABILITY: <br /> 80470 <br />SEAN THOMAS. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />RECOMMENDED FOR CONSTRUCTION: <br /> 62968 <br />JASON GABRIEL. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />A3.1-1 <br />BUILDING <br />ELEVATIONS <br />1. <br />2. <br />SEE A3.2-1 FOR WINDOW SCHEDULE AND <br />REPAIRS <br />SEE A3.3-2 FOR EXTERIOR DOOR SCHEDULE <br />#003 <br />ASI <br />#003 <br />ASI <br />#003 <br />ASI