Laserfiche WebLink
12345678910 <br />C <br />D <br />E <br />F <br />G <br />H <br />TODDLERS <br />AND <br />INFANTS <br />120 <br />GREAT <br />READING <br />ROOM <br />101 <br />YOUTH <br />STACKS <br />117 <br />MECH. <br />113 <br />MEN RR <br />110 <br />WOMEN RR <br />111 <br />STORAGE <br />108 <br />BOOKMOBILE <br />ROOM <br />103 <br />SORTING <br />123 <br />I.T. <br />106 <br />STAFF MEN <br />RESTROOM <br />105 <br />STAFF-WOMEN <br />RESTROOM <br />104 <br />ALL GENDER <br />RESTROOM <br />114 <br />ALL GENDER <br />RESTROOM <br />115 JAN. RM <br />112 <br />+8'-0" <br />BOOKSTORE <br />109 <br />+8'-0" <br />+8'-0" <br />+9'-0" <br />NURSING/SENSORY <br />116 <br />STORAGE <br />124 <br />REPLACE (E) 1'X1' CLG TILES <br />WITH NEW TILES, GRIDS AND <br />LIGHTS. <br />YOUTH AREA: <br />NEW ACT TILE AND NEW <br />GRID SYSTEM <br />OFFICE <br />103A+8'-0"+8'-0" <br />MEETING/COMMUNITY <br />ROOM <br />102 <br />VESTIBULE <br />107 <br />+9'-0" <br />+9'-0" <br />VESTIBULE <br />100 <br />+9'-0" <br />+8'-0" <br />+8'-0" <br />+8'-0"+8'-0" <br />DRAPES AND ROD 15'-8"W X 28' H <br />TRIM BETWEEN <br />CEILINGS @ <br />DIFFERENT HEIGHTS <br />+8'-0" <br />+8'-0" <br />+8'-6" <br />+8'-0" <br />+8'-0" <br />#002 <br />ASI <br />#002 <br />ASI #002 <br />ASI <br />ALIGN TILE PATTEN AT TWO <br />SURFACES <br />#002 <br />ASI <br />+9'-0" <br />+10'-2" <br />#12 <br />RFI <br />#38 <br />RFI <br />3' - 0 3/4"22' - 0" <br />+7'-6"+7'-6" <br />+8'-0" <br />+8'-0" <br />+9'-0" <br />+9'-0" <br />#43 <br />RFI <br />1' - 3 3/4"3' - 0 3/4" <br />2' - 3 3/8" <br />DEMO ABOVE 9'-0 A.F.F. <br />DEMO ABOVE 9'-0 A.F.F. <br />+9'-0" <br />DEMO ABOVE 9'-0 A.F.F. <br />+10'-0" <br />#60 <br />RFI <br />#020 <br />ASI <br />#020 <br />ASI <br />#020 <br />ASI <br />+10'-5" <br />#020 <br />ASI #020 <br />ASI <br />#020 <br />ASI <br />#020 <br />ASI <br />+9'-0" <br />#020 <br />ASI <br />14 <br />A9.4-1 7 <br />A9.4-1 <br />11 <br />A9.4-1 <br />7 <br />A9.4-1 <br />14 <br />A9.4-1SIM. <br />#020 <br />ASI <br />#120 <br />RFI <br />#109 <br />RFI <br />#120 <br />RFI <br />#120 <br />RFI <br />+7'-6"+7'-6" <br />+9'-4 1/2" <br />+8'-0" <br />HIGH CEILING FOR COMPACT SHELVING. <br />CEILING HEIGHT TO BE VERIFIED WITH SELECTED SHELVING MANUFACTURER <br />#142 <br />RFI <br />#142 <br />RFI <br />#023 <br />ASI <br />4" <br />11 <br />' <br /> <br />- <br /> <br />8 <br />" <br />1' <br /> <br />- <br /> <br />7 <br /> <br />1 <br />/ <br />4 <br />" <br />1' - 0 3/4"15' - 4"1' - 8" <br />5 <br />A9.4-210 <br />A9.4-3 <br />9 <br />A9.4-1 <br />7 <br />A9.4-1 <br />7 <br />A9.4-1 <br />#142.1 <br />RFI <br />#142.1 <br />RFI <br />REFLECTED CEILING PLAN LEGEND <br />G-1: <br />GYPSUM BOARD CEILING PTD. <br />ACT-2: <br />2'X4' ACOUSTIC CEILING TILE <br />ACT-1: <br />1'X1' ACOUSTIC CEILING TILE <br />W-1: <br />CUSTOM WOOD GRILLE WITH ACOUSTIC <br />BACKING <br />OPEN TO STRUCTURE ABOVE <br />C -1: <br />CEMENT PLASTER <br />(E) CEILING TO REMAIN <br />#002 <br />ASI <br />1. <br />2. <br />LIGHT FIXUTRE AND LIGHTING SCHEDUDLE REFER TO <br />ELECTRICAL DRAWING (E. SERIES) FOR GRAPHIC AND <br />DETAILS <br />NOT ACCEPTABLE TO RUN THE CONDUIT EXPOSED#002 <br />ASI <br />ST <br />09-30-2025 <br />O <br />ARCHITECT <br />FOFCALE <br />REN. <br />AT ARN <br />NO. <br />SE <br />LICNE <br />C-27893 <br />D <br />T <br />EC <br />HIT <br />ARC <br />DAVID SCHNEE <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />F R A N CN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />N D E N VA <br />,N I N G <br />CRAE <br />TCEIT <br />S C <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />0718 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />SHEET NOTES <br />N <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />PERMIT SET 1ST ISSUANCE <br />BID SET <br />FINAL PERMIT/CONFORM SET <br />09/29/2023 <br />04/30/2024 <br />08/02/2024 <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />REV # DESCRIPTION DATE <br />1 BACKCHECK REV-1 03.01.2024 <br />2 CITY REVIEW REV-1 08.02.2024 <br />3 CITY REVIEW REV-2 10.18.2024 <br />4 CITY REVIEW REV-3 01.27.2025 <br />5 CITY REVIEW REV-4 04.07.2025 <br />6 CITY REVIEW REV-5 06.27.2025 <br /> <br />REVIEWED FOR CONSTRUCTABILITY: <br /> 80470 <br />SEAN THOMAS. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />RECOMMENDED FOR CONSTRUCTION: <br /> 62968 <br />JASON GABRIEL. P.E. RCE NO: <br />PRINCIPAL CIVIL ENGINEER <br />DATE: <br />A6.0-2 <br />REFLECTED <br />CEILING PLAN- <br />FIRST FLOOR <br /> 1/8" = 1'-0"1 RCP01-REFLECTED CEILING PLAN- FIRST FLOOR