Laserfiche WebLink
SYMBOL MANUFACTURER/MODEL/DESCRIPTION ARC PSI GPM RADIUS <br />RAIN BIRD RD-06-S-P30-F-U 08 HE-V <br />TURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEM <br />PRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE, <br />AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALE <br />THREADED INLET. <br />ADJ 30 ≤ 1.19 8' <br />RAIN BIRD RD-06-S-P30-F-U 12 HE-V <br />TURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEM <br />PRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE, <br />AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALE <br />THREADED INLET. <br />ADJ 30 ≤ 2.38 12' <br />RAIN BIRD RD-06-S-P30-F-U 15 HE-V <br />TURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEM <br />PRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE, <br />AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALE <br />THREADED INLET. <br />ADJ 30 ≤ 3.71 15' <br />RAIN BIRD 1806-1400 FLOOD 1401 <br />FLOOD BUBBLER 6.0IN. POPUP <br />360 20 0.25 3' <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION <br />PIPE TRANSITION POINT <br />PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP <br />TUBING WITH RISER TO ABOVE GRADE INSTALLATION. <br />RAIN BIRD MDCFCAP <br />DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING <br />COUPLER. <br />RAIN BIRD ARV050 <br />1/2IN. AIR RELIEF VALVE WITH A 6IN. DRIP VALVE BOX (SEB <br />7XB EMITTER BOX). USE WITH INSTALLATION BELOW SOIL. <br />HUNTER SD-B-STK <br />MICRO SPRAY FOR RESIDENTIAL/COMMERCIAL USE. EIGHT <br />STREAMS OF WATER, WITH 360 DEGREE SPRAY. 15PSI TO <br />30PSI. SOLO-DRIP WITH BARB AND 6IN. STAKE. <br />AREA TO RECEIVE DRIPLINE <br />RAIN BIRD XFS-04-18 <br />XFS SUB-SURFACE PRESSURE COMPENSATING DRIPLINE <br />W/COPPER SHIELD TECHNOLOGY. 0.4 GPH EMITTERS AT <br />18" O.C. LATERALS SPACED AT 18" APART, WITH EMITTERS <br />OFFSET FOR TRIANGULAR PATTERN. UV RESISTANT. <br />SPECIFY XF INSERT FITTINGS. <br />SYMBOL MANUFACTURER/MODEL/DESCRIPTION <br />RAIN BIRD EFB-CP <br />1IN. BRASS REMOTE CONTROL VALVE, THAT IS <br />CONTAMINATION PROOF W/SELF-FLUSHING FILTER <br />SCREEN. GLOBE CONFIGURATION, <br />RAIN BIRD EFB-CP-PRS-D <br />1IN. BRASS REMOTE CONTROL VALVE, THAT IS <br />CONTAMINATION PROOF W/SELF-FLUSHING FILTER <br />SCREEN. GLOBE CONFIGURATION. USE NIBCO T-113-K <br />GATE VALVE BEFORE VALVE. ADD RAIN BIRD PRF-100-RBY <br />FILTER WITH VALVE. <br />HUNTER HQ-5LRC <br />QUICK COUPLER VALVE, YELLOW LOCKING RUBBER <br />COVER, RED BRASS AND STAINLESS STEEL, WITH 1IN. NPT <br />INLET, 1-PIECE BODY. <br />NIBCO T-113-K <br />CLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSS <br />HANDLE, SAME SIZE AS MAINLINE PIPE DIAMETER AT <br />VALVE LOCATION. <br />GRISWOLD 2160 1-1/2" <br />1IN.-8IN. SOLENOID, NORMALLY OPEN MASTER VALVE. <br />CAST IRON AND BRONZE MATERIAL. NPT END <br />CONNECTION. <br />FEBCO LF850-U-S 2" <br />REDUCED PRESSURE BACKFLOW ASSEMBLY <br />CALSENSE CS3000-32-S/CS3-GR-KIT/TP-110 <br />CS3000 SERIES 32 STATION AUTOMATIC CONTROLLER <br />WITH STAINLESS STEEL TOP-ENTRY PEDESTAL <br />ENCLOSURE AND 4G LTE CELLULAR MODEM WITH <br />ANTENNA. FLOW METER TO BE INSTALLED, SEE SEPARATE <br />CALLOUT. CONTRACTOR TO CONTACT CITY PUBLIC <br />WORKS PRIOR TO PURCHASING TO VERIFY <br />COMMUNICATIONS OPTIONS, EXISTING CALSENSE <br />CELLULAR DATA PLAN, AND EXISTING INTEGRATION WITH <br />PLAYGROUND. <br />CALSENSE REP: DAVID MEEHAN (760) 580-1829 <br />CALSENSE FM-1.5B <br />1.5" BRONZE FLOW METER IN 1" BRASS TEE. WIRE <br />CONTROLLER USING #14 AWG WIRE IN 1" CONDUIT, <br />INSTALL PER MANUFACTURERS RECOMMENDATIONS. <br />MULTIPLE FLOW SENSORS REQUIRE SEPARATE CONDUIT <br />RUNS. <br />STRONG BOX SBBC-45CR <br />LOW PROFILE, TUBE AND WIRE CONSTRUCTION SMOOTH <br />TOUCH SURFACE, COLD ROLLED STEEL, BACKFLOW <br />ENCLOSURE. 46.5IN.L, 28IN.H, 17.75IN.W. <br />CALSENSE RB-1 TIPPING BUCKET RAIN SENSOR <br />MOUNT TO BUILDING UNDER CITY AND HISTORICAL <br />ARCHITECT REVIEW. WIRED PER MANUFACTURERS <br />INSTRUCTIONS <br />WATER METER 2" <br />DOMESTIC WATER. SEE POINT OF CONNECTION NOTES. <br />IRRIGATION LATERAL LINE: PVC SCHEDULE 40 <br />SEE PIPE SIZING CHART <br />IRRIGATION MAINLINE: PVC CLASS 315 SDR 13.5 <br />PIPE SLEEVE: PVC SCHEDULE 40 <br />8 <br />21 <br />51 <br />NO SYMBOL <br />360 <br />MV <br />BF <br />A <br />FS <br />BE <br />RS <br />M <br />FLOW AVAILABLE <br />Water Meter Size: <br />Flow Available <br />PRESSURE AVAILABLE <br />Static Pressure at POC: <br />Elevation Change: <br />Service Line Size: <br />Length of Service Line: <br />Pressure Available: <br />DESIGN ANALYSIS <br />Maximum Station Flow: <br />Flow Available at POC: <br />Residual Flow Available: <br />Critical Station: <br /> Design Pressure: <br /> Friction Loss: <br /> Fittings Loss: <br /> Elevation Loss: <br /> Loss through Valve: <br />Pressure Req. at Critical Station: <br />Loss for Fittings: <br />Loss for Main Line: <br />Loss for POC to Valve Elevation: <br />Loss for Backflow: <br />Loss for Master Valve: <br />Loss for Water Meter: <br />Critical Station Pressure at POC: <br />Pressure Available: <br />Residual Pressure Available: <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />Z <br />CIVIC CENTER DRIVE <br />RO <br />S <br />S <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />LI <br />M <br />I <br />T <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />LIMIT OF WORK <br />SANTA ANA LIBRARY <br />LIMIT OF WORK <br />LIMIT OF WORK <br />PA <br />R <br />K <br />I <br />N <br />G <br /> <br />S <br />T <br />R <br />U <br />C <br />T <br />U <br />R <br />E <br />LI <br />M <br />I <br />T <br /> <br />O <br />F <br /> <br />W <br />O <br />R <br />K <br />KID'S AREA <br />N.A.P. <br />T <br />R <br />TR <br />EV <br />CAPABLE <br />PARKING <br />STALL <br />EV <br />CAPABLE <br />PARKING <br />STALL <br />EV <br />CAPABLE <br />PARKING <br />STALL <br />EV <br />CAPABLE <br />PARKING <br />STALL <br />TR <br />EXISTING <br />TO <br />REMAIN <br />A <br />6.53A-4 <br />1"Area for Dripline <br />ZONE <br />10.4A-5 <br />1"Area for Dripline <br />ZONE <br />5.45 A-3 <br />1"Area for Dripline <br />ZONE <br />21 2121 <br />51 <br />51 21 <br />21 <br />21 <br />2121 <br />51 <br />51 21 2121 <br />21 <br />21 <br />21 <br />21 <br />21 51 51 <br />51 <br />51 <br />51 21 <br />2151 <br />51 <br />51 <br />3 4" <br />3 4"1" <br />1" <br />3 4"3 4" <br />3 4" <br />114"3 4" <br />3 4" <br />1"3 4" <br />1"3 4" <br />3 4" <br />6A-6 <br />1"Bubbler <br />ZONE <br />1.91A-7 <br />1"Area for Dripline <br />ZONE <br />16.9A-8 <br />1"Area for Dripline <br />ZONE <br />A-920.5 <br />1"Turf Spray <br />ZONE <br />A-109.2 <br />1"Turf Spray <br />ZONE <br />10.4A-11 <br />1"Turf Spray <br />ZONE <br />20.7A-12 <br />1"Turf Spray <br />ZONE <br />A-1310.7 <br />1"Area for Dripline <br />ZONE <br />A-143.5 <br />1"Bubbler <br />ZONE <br />2" <br />2" <br />BE <br />1" <br />1" <br />A-17.36 <br />1"Area for Dripline <br />ZONE <br />A-22 <br />1"Bubbler <br />ZONE <br />3 4" <br />51 <br />51 <br />21 <br />21 <br />21 21 <br />21 <br />21 21 <br />21 <br />21 <br />21 <br />51 <br />888 <br />8 <br />8 <br />3 4" <br />3 4"3 4" <br />3 4" <br />M <br />BF FS MV <br />3 4" <br />2" <br />RS <br />11 4" <br />1" <br />11 4" <br />1" <br />114" <br />11 4" <br />1" <br />3 4" <br />114"11 4" <br />3 4"3 4" <br />#" <br />## <br /># <br />VALVE CALLOUT <br />VALVE NUMBER <br />VALVE FLOW <br />HYDROZONE <br />VALVE SIZE <br />terra n <br />I N T E G R A T I O N <br />Landscape Architecture CA#5231 <br />Planning + Design + Sustainability <br />143 S. Olive St. <br />Orange I CA I 92866 <br />714-724-9814 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />REV #DESCRIPTION DATE <br />#9 RFI 10.23.2024 <br />BID SET 04/30/2024 <br />FINAL PERMIT/ CONFORM SET 08/02/2024 <br />#19 RFI 3.28.2025 <br />#20 RFI 3.28.2025 <br />#57.1 RFI 6.18.2025 <br />IRRIGATION <br />PLAN <br />LA-3.0 <br />1.POINT OF CONNECTION (POC) SHALL BE AT NEWLY PROVIDED 2" WATER METER AND SERVICE LINE. INSTALL <br />NEW 2" BACKFLOW PREVENTOR, 1 1/2" MASTER VALVE, AND 1 1/2" FLOW METER AT LOCATION INDICATED ON <br />CIVIC CENTER DRIVE. REFERENCE CIVIL ENGINEERING UTILITY PLANS FOR MORE INFORMATION <br />2.CONTRACTOR SHALL CAP EXISTING IRRIGATION TO SITE AND ABANDON CURRENT OPERATING EQUIPMENT. <br />NEW IRRIGATION SHALL BE INSTALLED PER PLAN. <br />3.THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION AND WATER PRESSURE IN THE FIELD PRIOR TO <br />STARTING WORK. THE DYNAMIC WATER PRESSURE SHALL BE MEASURED AT THE MAXIMUM SYSTEM DEMAND <br />AS INDICATED BELOW. IF ANY OF THE POC INFORMATION SHOWN ON THESE DRAWINGS IS FOUND TO BE <br />DIFFERENT THAN THE ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE <br />LANDSCAPE ARCHITECT,SHOULD THE CONTRACTOR FAIL TO VERIFY THE POC INFORMATION AS SHOWN <br />HEREIN, ANY CHANGES REQUIRED BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF <br />THE CONTRACTOR AT NO ADDITIONAL COST TO THE CITY/ OWNER. <br />WATER PRESSURE AT METER 60-65 PSI <br />DESIGN WATER PRESSURE 30 PSI <br />4.CONTROLLER NOTE: <br />4.1.THE CONTRACTOR SHALL REMOVE THE EXISTING IRRIGATION CONTROLLER, AND INSTALL NEW CALSENSE <br />CONTROLLER PER IRRIGATION LEGEND. RE-ESTABLISH CONNECTION TO EXISTING POWER SUPPLY. <br />CONNECT & INTEGRATE EXISTING PLAYGROUND STATIONS INTO NEW CONTROLLER. <br />1.CONTRACTOR TO INSTALL ALL IRRIGATION EQUIPMENT WITHIN LIMIT OF SITE WORK. SHOWN FOR CLARITY <br />ONLY - IRRIGATION IS SCHEMATIC. <br />2.THE IRRIGATION PLAN IS DIAGRAMMATIC. CONTRACTOR CAN ROUTE PIPING IN A FREE FORM MANNER, <br />AVOIDING OBJECTS LIKE LIGHT STANDARDS, TRANSFORMER PADS, EQUIPMENT VAULTS, SUB-SURFACE <br />ROCK TOO LARGE TO REMOVE, ETC. <br />DRIPLINE NOTES <br />LATERAL PIPE SIZING <br />FLOW PIPE SIZE FLOW PIPE SIZE <br />0-8 GPM 3/4"22.1-28 1 1/2" <br />8.1-12 GPM 1"28.1-45 2" <br />12.1-22 GPM 1 1/4"45.1+2 1/2" <br />COMPLIANCE NOTE <br />I HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND APPLIED THEM FOR THE <br />EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLANS. <br />3/17/2022 <br />LANDSCAPE ARCHITECT DATE <br />POINT OF CONNECTION NOTES <br />IRRIGATION LEGEND <br />INSTALL BUBBLERS ON OUTER EDGE <br />OF MULCH LINE. <br />SEE PLANTING PLAN FOR MULCH LINE. <br />WIRE SLEEVE: PVC SCHEDULE 40. <br />BURY MIN. 24" BELOW GRADE, EXTEND MIN. 12" BEYOND EDGE. <br />NO SYMBOL <br />NORTH 0 10'20'40' <br />SCALE: 1" = 20'-0" <br />CONNECT NEW MAINLINE TO <br />EXISTING MAINLINE SERVICING <br />CHILDREN'S PLAYGROUND <br />THROUGH SHUT OFF VALVE. <br />SHUT OFF VALVE TO BE LOCATED IN <br />EXISTING PLANTER AND TO RECEIVE <br />3" LAYER OF BARK MULCH PER <br />PLANTING PLANS <br />CONTRACTOR TO REMOVE EXISTING <br />BACKFLOW, MASTER VALVE, AND <br />FLOW SENSOR ONLY. <br />EXISTING CHILDREN'S PLAYGROUND <br />IRRIGATION TO BE INCORPORATED <br />INTO NEW OVERALL LIBRARY <br />IRRIGATION SYSTEM <br />REFER TO CIVIL PLANS PREPARED BY <br />KPFF/ UTILITY PLAN SHEET C1-5.1 FOR <br />MORE INFORMATION AND COORDINATION <br />PRESSURE MAINLINE SHALL BE LOCATED <br />IN PLANTER IN A LOCATION FREE OF <br />OBSTRUCTIONS AND MINIMUM OF 5' <br />FROM TREE ROOTBALL. PLAN SHOWN <br />FOR CLARITY PURPOSES ONLY. <br />ASI <br />#19 <br />ASI <br />#19 <br />ASI <br />#20 <br />ASI <br />#20 <br />ASI <br />#20 <br />ASI <br />#20 <br />ASI <br />#20 <br />RFI <br />57.1