Laserfiche WebLink
VL Plus <br />0'n---„7./C . .r _ <br />Installatien Guide for 701269-(XXX)Al-MB, 701269-VWL(X)-MB, 701269LRVL(X)-MB <br />For layout guidelines for VL Plus either test or contact your SloanLED representative for recommendations. <br />DC 12 V Power Supply capacity table for VL Plus <br />Input Output Maximum feet (meter)/ Modules <br />Power Supply Part # (Each)Nominal Input Input Powef Qutput Red Red, Orange &Green & Blue White White White <br />Voltage Current Output Current Long Yellow Short ,Short Long Short Mini <br />Self Contained 20 701680 i20-240V 0.3 A 20 W 1.5A 25 <7,6)150 25 7,3)62 20 (6,1)/50 25 (7,6)/50 20(6.1)50 16(4,9)/65 <br />MODW 60 W 701507·MODW 120.240 V 1.0A 60 W 4.5 A 75 (23)/150 75 (22,9)/187 60(18,3y150 75(236'150 60:(183yl502 49(14,9)196 <br />(North Ameiica) <br />MODWE 60 W 701507-MODWE 100-240 V 1.0 A i60 W 4.5 A :75 (23)/150 75 (22,9yl 87 60 (18,3)/150 75 (23)/150 60 (18,3)/150 49 (14i9)/196 <br />(Eulope) <br />Mod 60-277 701507-MOD277 277-347 V 0.5A 60 W 4.5 A 75 (23)/150i 75 (22,9)/187 60(18,31/150 75 (23f150 60(18,311150 49(14,91/196 <br />Poweriused per foct (ineter) in Watts 0.72 (2,35)0 73 (2,38)0.90 (2,95)0.72 (2,35)0.90 (2,95) 1.12(3,67) <br />Extension of Power Supply Leads <br />If longer lead wire from power'supply 10 LED modules is needed, afl extension can be used. Extension should be kept as short as possible: <br />under 15 11 for 18 A.WG UL Listed PLTC or under 50 ft for 14 AWG UL Listed PLTC. (4,6 m for 1 mm' or under 15,2 m for 2,5 mm2). <br />Troubleshooting: <br />Entire sign or leg does not light <br />after complete installation. <br />Check connection from power supply lead to first module. Make sure polaniy of connections made ai the power supply lead <br />and any jumper wire is correct. Po,Val supply outputs should be connected RED-TO-RED and BLACK-TO-BLACK. <br />Still does not light.Check output voltage,of power supply using a vollineter The cutput voltage should be DC 12.0 V. 0 5 V If there is no <br />output voltage, have a licensed electrician check input voltage Make sure power supply is connecied coirectly and getting <br />primary power. I f power supply is connected properly and getting primary, power and there is siill no output voltage, try a <br />different powef supply <br />Still does not light.If power supply is getting pfimaty power and the modules don't light, there may be a -short in the secondary wiring. Chick 411 <br />connections and cap all loose wires. <br />The beginning of a leg lights, but The primary cause of a portion of a VL Plud leg not lighting or ligh,ing intermittently'is a bad connection or reverse polarity <br />the entire leg does not light or connection between the modules lhal light and the modules that don't light Check this·conrection. <br />lights intermittently. <br />One module does not light, but VL Plus modules are designed that if one module fails. it will not cause the entire sigh or leg to go out. If one module does <br />all others in the leg light.not light but all others in the leg do, replace this module with a new one. <br />r , a. R€fHSC 1.IUS 5 -0- Compliant IN <br />Customer service and technical support <br />888747 4LED (888 747 4533) <br />SloanLED com · info@SloanLED com <br />P N 40 1014 Rev C 2013-08*02 <br />Europe, Customer ser'vice and technical suppod <br />+31 (15) 3641569 <br />SloanLED com · Europe@SloanLED com *SloanLED' <br />4 Leaders in LED Technology