GROUND-FAULT DETECTION AND INTERRUPTION; <br />TO BE INSTALLED AT INVERTER PER <br />NEC 2011 690.5 (C) <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND ENERGIZED <br />DISCONNECTION MEANS; TO BE INSTALLED <br />AT ALL AC AND DC DISCONNECTS <br />RESPECTIVELY PER NEC 2011 690.14(C)(2) <br />SOLAR AC DISCONNECT <br />SOLAR DC DISCONNECT <br />DISCONNECTING MEANS MAY BE ENERGIZED IN <br />THE OPEN POSmON; TO BE INSTALLED <br />AT DISCONNECTING MEANS <br />PER NEC 2011 690.17 <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSITION. <br />PHOTOVOLTAIC POWER SOURCE SHALL BE <br />LABELED WITH THE FOLLOWING WARNING AT <br />EACH JUNCTION BOX, COMBINER BOX, <br />DISCONNECT, AND DEVICE WHERE ENERGIZED, <br />UNGROUNDED CIRCUITS MAY BE EXPOSED <br />DURING SERVICE PER NEC690.35(F) <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE ENERGIZED <br />INVERTER OUTPUT CONNECTION TO BE <br />INSTALLED AT MAIN SERVICE PANEL <br />PER NEC 2011 705.12 (D)(7) <br />WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />MARKING SHOULD BE PLACED ON ALL <br />INTERIOR AND EXTERIOR PV CONDUIT, <br />RACEWAYS, ENCLOSURES, AND CABLE <br />ASSEMBLIES, EVERY 10 FEET, AT TURNS AND <br />ABOVE AND/OR BELOW PENETRATIONS AND <br />All PV COMBINER AND JUNCTION BOXES. <br />o SHALL BE REFLECTIVE WEATHER <br />RESISIANT MATERIAL <br />CAUTION: SOLAR CIRCUIT <br />TO BE LOCATED AT MAIN SERVICE PANEL: <br />CAUTION: <br />SOLAR EL-ECTRIC SYSTEM CONNECTED <br />TO BE INSTALLED ON THE FACE OF THE <br />SERVICE METER PANEL PER <br />NEC 2011 705.10 <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPUED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />W HEMLOCK WAY AT: 9 <br />METER AND MAIN SERVICE <br />1--1 %\ /5,/AC DISCONNECT <br />® DC DISCONNECTINVERTER <br />® <br />DIRECT-CURRENT PHOTOVOLTAIC POWER <br />SOURCE TO BE INSTALLED AT <br />INVERTER PER NEC 690.53 & 690.54 <br />OPERAnNG CURRENT: 8A <br />OPERAnNG VOLTAGE: 395V <br />SHORT-CIRCUIT CURRENT: 1 OA <br />MAX SYSTEM VOLTAGE: 559V <br />DIRECT--CURRENT PHOTOVOLTAIC POWER <br />SOURCE TO BE INSTALLED AT AC <br />DISCONNECT PER NEC 690.54 <br />AC OUTPUT CURRENT 234 <br />NOMINAL OPERATING VOLTAGE: 240V <br />/= t <br />0 <br />MARKING CONTENT AND FORMAT <br />0 RED BACKGROUND <br />o WHITE LETTERING <br />o MINIMUM 3/8' LETTER HEIGHT <br />u ALL CAPITAL LETTERS <br />0 ARIAL OR SIMILAR FONT, NON-BOLD <br />c] WEATHER RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />(DURABLE ADHESIVE MATERIALS MUST <br />MEET THIS REQUIREMENT <br />MAX PV VOLTAGE & CURRENT CALC'S: ACCONDUCTOR AMPACITY CALCULATIONS: <br />RECORD LOW TEMP. CC): -5' <br />VOLTAGE CORRECTION PER NEC 690.7: 1.12 <br />MAX PV SYSTEM VOLTAGE (PER NEC 690.7): <br />Vcorrection X Voc X # MODULES IN SERIES <br />1.12 X 38.40 X 13 = 559.10V <br />MAX PV CURRENT PER NEC 690.8(A)(1): <br />1.25 X Isc <br />1.25 ;X 8.79 = 10.99A <br /># OF INVERTERS: 1 <br />EXPECTED WIRE TEMP ¢C): 41 <br />TEMP CORRECnON PER NEC TABLE 310.15(B)(16): 0.87 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br /># OF CURRENT CARRYING CONDUCTORS: 3 <br />CONDUIT FILL PER NEC 310.15(B)(3)(a): 1 <br />CIRCUIT CONDUCTOR AMPACITY: 40 A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): <br />1.25 X MAX INVERTER OUTPUT CURRENT= <br />1.25 X 23.00 = 28.75 A <br />DC CONDUCTORAMPACITY CALCULATIONS: <br />ARRAY TO JUNCTION BOX <br />EXPECTED WIRE TEMP (°C): 41' <br />TEMP CORRECTION PER TABLE 310.15(B)(16): 0.87 <br /># OF CURRENT CARRYING CONDUCTORS: 4 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 0.8 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40 A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.80\&B): <br />1.25 X 1.25 X Isc = <br />1.25 X 1.25 X 8.79 = 13.73A <br />DERATED AMPACHY OF CIRCUIT CONDUCTOR PER NEC TABLE <br />310.15(B)(16) <br />TEMP CORR. PER NEC TABLE 310.15(B)(16) X <br />CONDUIT FIU CORR. PER NEC 310.15(B)(3)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.87 X 0.8 X 40 = 27.84A <br />DERATED Al,PACIP( OF- aRCUIT CaiDUC[ORS PER NEC TABLE <br />310.15(B)(16): <br />TEMP CORR. PER NEC 310.15(B)(16) X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.87 X1X40= 34.80 A <br />DC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM JUNCTION BOX TO INVERTER <br />AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT <br />PER NEC 310.15(B)(3)(c): + 22 <br />EXPECTED WIRE TEMP ¢C): 41' + 22° <br />TEMP CORRECTION PER TABLE 310.15(B)(16): 0.58 <br /># OF CURRENT CARRYING CONDUCTORS: 4 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 0.8 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40 A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.80&8): <br />1.25 X 1.25 X Isc <br />1.25 X 1.25 X 8.79 = 13.73 A <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE <br />310.15(B)(16) <br />TEMP CORR. PER NEC TABLE 310.15(B)(16) X <br />CONDUIT FIll CORR. PER NEC 310.15(B)(3)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.58 X 0.8 X 40 = 18.56 A€] <br />91 <br />'Al <br />CO