My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180865_3120 W. LAKE CTR DR. - Plan
PBA
>
Building
>
Plans
>
L
>
Lake Center Dr
>
3120 W Lake Center Dr
>
10180865_3120 W. LAKE CTR DR. - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2021 5:00:03 PM
Creation date
10/25/2020 5:21:13 PM
Metadata
Fields
Template:
Plan
Permit Number
10180865
Full Address
3120 W Lake Center Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Show annotations
View images
View plain text
October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 54 <br />GEPS24-20, a temperature test is required when installed in an enclosure srnaller than 13.5 by 6 by 4 inches, but the maximum <br />temperature on the output transformer by thermocouple is 90°C. <br />4. The output of these LED power supplies with Class 2 are acceptable for use in a damp and wet locations. <br />Power supplies with Class 2 outputs, Model GEXNPS30. <br />1 This component has outputs that qualify as being Class 2. <br />2. These components are intended for use in dry location only. <br />3. The transformer employs a Class B (130) Insulation System. <br />4 These components shall be installed in compliance with the enclosure and mounting requirements of the ultimate application. <br />5. The maximum room ambient temperature permitted by the manufacture is 50*. <br />6. A Temperature Test is required of the power supply installed in an enclosure that measures less than 13.5 by 6 by 4 inches. The <br />maximum temperature on the output transformer by thermocouple is 110( C. <br />Powersupplies with Class 2 outputs, Models GEPS24-180U, GE180/MVA/24T1-C <br />1. The maximum measured output voltage, current and power at the output of these models was found in compliance with the <br />limits for LPS output requirements and additionally evaluated to comply with Class 2 output criteria. <br />2. The transformer employ Class B insulation system. <br />3. Power Supply is intended for use in indoor Dry and Damp location only. <br />4. In the end product. power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in <br />any other direction. <br />5. Input and Output leads are style 1316, rated 600 V, 105°C, VW-1. Minimum No. 18 AWG. The suitability of input and output <br />connections shall be determined in each end use application. <br />6. The power supply was submitted and tested for a maximum manufacturers recommended Tb point described in the table below <br />If adjacent LED power supplies are spaced closer than 1 In. end to end or 4 in. side to side a temperature test shall be <br />conducted inthe_e-nd-use product. <br />Model Input Voltage, HZ Max. Case Temp @ Tc, °C Ambient, °C <br />GE180/MVA/24T1 -C,'GEPS24 100-277,60 80 60 <br />180U <br />LED Light Engine, Cat. Nos. 11 10-WH-ZZ-TTK, 11 10-RD-ZZ-TTK, catalog numbers where: "ZZ" representing assembly version: <br />followed by: "TT" - Optional - represents the color temperature of the LEDs in degree "K" Kelvin. Cat. Nos. 1111-XX-ZZ-Y-TTK. <br />catalog numbers may vary per nomendature.: "XX" representing color: RD, RC, YG, GL, SB, BL, WH, YA, WW, GR, PO; "ZZ" <br />representing assembly version; "Y- representing number of LEDs; followed by: "TT" - Optional - represents the color temperature of <br />the LEDs in degree "K" Kelvin. <br />1. These products are only suitable for connection to a Cla5s 2 power source. <br />2. When units are connected to a Class 2/"LPS' circuit, they are not to draw a total wattage of greater than the secondary or output <br />rating of the Class 2/'LPS" supply. <br />3. Ihese products are suitable for use in dry, damp and wet locations. <br />4. The suitability of the LED Light Engine mounting means shall be determihed in the end-use application. <br />5. The suitability of the LED Light Engine to be used without an additional electrical enclosure shall be determined in the end-use <br />application. <br />6. These products described in this section may be cut into segments per rrlanufacture insulation instructions. <br />7. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 "Conditions of <br />Use" as defined in the Sign Components Manual. <br />LED Driver with Class 2 Output, Models GEPS120-604 GEPS240-80U. <br />1. These LED Drivers have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 output. <br />2. These products are proyided with the following electrical ratings: <br />Mo(lei No.Input Voltage (V Input Freq Input Current Output Voltage Output Current Output <br />ac) (HZ) (A) (V dc) (A) Power OAD <br />]GEPS24D-80U 100-277 50/60 1.1 24 3.3 80 <br />jGEPS 12[)-60U 100-277 50/60 0.85 12 5.0 60 <br />3. The load powered by the Class 2 output of the LED drivers are suitable for use in dry, damp and wet locations. <br />4. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and <br />minimum 2 inches spacing to top of enclosure. <br />5. In Ihe end product, LED Drivers shall be located not less than 1 inch (25.4mm) apartwhen arranged end-to-end, and not less <br />than 4 inches (102mm) apart when arranged otherwise. <br />6. These products shall be enclosed in the end product. <br />7. Tbe unit is intended for being used in permanently wired signs. <br />8. The suitability of output leads, rated No. 24 AWG minimum, rated 80°C minimum, 600 V, shall be determined in end product <br />use. <br />9. T.hese units may provided with Dimming Input (Purple and Gray wires) to control output current range, the suitability shall be <br />determined in each end-use application. <br />10. These products are intended for use in dryiand damp locations <br />LED Driver with Class 2 Output, Model 1110PS-60S. <br />1. These LED drivers have been evaluated using resistive load resulting in the electrical input and output noted on page 1. <br />2. These LED drivers are provided with Class 2 output. <br />3. These LED drivers are intended to be operated in a maximum ambient (Ta) noted as below: <br />Model Ta (°C) <br />LD-60-UV-1214V 40 <br />4. These LED drivers are intended for use in dry and damp locations except that models LID-60-UV-1214V and LD-60-UV-12149- <br />SC are suitable for dry location only. <br />5. These LED drivers are provided wth 18 AWG AWM input and output leads. The suitability of the wiring and the need for a <br />suitable enclosure shall be considered in the end product.
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).