My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180921_3725 S. GARNSEY - Plan
PBA
>
Building
>
Plans
>
G
>
Garnsey St
>
3725 S Garnsey St
>
10180921_3725 S. GARNSEY - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2021 11:48:29 PM
Creation date
10/25/2020 5:21:20 PM
Metadata
Fields
Template:
Plan
Permit Number
10180921
Full Address
3725 S Garnsey St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2 STRINGS OF 11 MODULES <br />SMX CAPITAL: SMX250P, 250W <br />TOTAL OUTPUT: 5,500 WATTS <br />- (4) #10 AWG USE-2 <br />(1) #6 BARE CU EGC <br />@e <br />INVERTER 1 <br />SMA AMERICA: SB-5000TL-US-22 <br />240VAC <br />WITH INTEGRATED DC DISCONNECT <br />UL 1741 LISTED, GFP. <br />(3) #10 THHN/THWN-2 <br />(1) #8 THHN/THWN-2 GROUND <br />3/4" EMT CONDUIT <br />MAX CURRENT: 27.5A <br />NEW <br />200 AMP <br />ELECTRICAL <br />SERVICE ENTRANCE <br />AND LOAD CENTER <br />81-DIRECTIONAL <br />UTILITY METER <br />240V 200A <br />L.ze-J <br />15A FUSED <br />DC <br />DC DISCONNECT <br />1 <br />-(4) #10 THHN/THWN-2 <br />(1) #8 THHN/THWN-2 EGC <br />3/4" EMT CONDUIT <br />4 <br />Ulei <br />n-RON-1 111PHOTOVOLTAIC SYSTEM \ <br />KILOWATT-HOUR METER \ <br />1004240VAC (TYP) \ <br />C FUSIBLE <br />AC DISCONNECT ) <br />2P30A 240V 3- ® <br />ioA .I- <br />1,-. ' <br />.39 2P200A <br />2P2 <br />UTILITY GRID <br />120/240V <br />WIRE TYPE SHALL BE 90° C <br />WET AND CONTINUOUS RATED <br />L SPS OUTLET MAX 120V/12A 150OW (TYP EACH INVERTER) <br />A NORMALLY INERACTIVE SOLAR PHOTOVOLTAIC SYSTEM <br />SHALL BE PERMITTTED TO OPERATE AS A STAND-ALONE <br />SYSTEM TO SUPPLY LOADS THAT HAVE BEEN DISCONNECTED <br />FROM ELECTRICAL PRODUCTION AND DISTRIBUTON NETWORK <br />SOURCES (CEC, NEC 690.61). <br />SINGLE PHASE <br />W <br />BUILDING <br />GROUNDING <br />ELECTRODE <br />NOTES:SYSTEM OUTPUT:BACKFED BREAKER SHALL BE POSITIONED AT - <br />1. ALL PV SYSTEM COMPONENTS SHALL BE USED BY A RECOGNIZED <br />TESnNG AGENCY (i.e., UL 1741, ETC) <br />2. WIRING MATERIALS SHALL BE SUITABLE FOR lHE SUN EXPOSURE AND WET <br />LOCATIONS. FIELD APPUED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. <br />3. WHERE THE TERMINAL OF THE DISCONNECTING MEANS MAY BE ENERGIZED <br />IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR <br />ADJACENT TO THE DISCONNECTING MEANS HAVING THE FOLLOWING <br />WORDS: "WARNING-ELECTRIC SHOCK HAZARD, DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH UNE AND LOAD SIDES MAY BE ENERGIZED IN THE <br />OPEN POSInON" <br />4. SIGNS SHALL BE POSTED ADJACENT TO EACH PV DISCONNECT AND <br />INVERTER TO INDICATE "PHOTOVOLTAIC SYSTEM" <br />5. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL <br />SHALL BE PROTECTED FROM PHYSICAL DAMAGE. <br />6. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED <br />BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY <br />DISPLACEMENT OF A MODULE(S) OR PANEL-(S) SECURED BY REMOVABLE <br />FASTENERS. <br />7. EACH SIDE OF A POWER TRANSFORMER SHAU BE CONSIDERED AS <br />PRIMARY AND PROTECTED IN ACCORDANCE WITH CEC 2013. <br />8. REMOVAL OF INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT <br />THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE <br />CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT <br />GROUNDED CONDUCTOR. <br />9. THE CIRCUIT CONDUCTORS AND OVERCURRENT DEVICES SHALL BE SIZED <br />TO CARRY NOT LESS THAN 125% OF THE MAXIMUN CURRENT AS <br />CALCULATED IN CEC 2013. <br />10. THE OVERCURRENT PROTECTION OF OUTPUT CIRCUITS WITH INTERNAL <br />CURRENT UMInNG DEVICES SHALL BE NOT LESS THAN 125% OF THE <br />MAXIMUM UMITED CURRENT OF THE OUTPUT CIRCUIT. THE CONDUCTORS IN <br />SUCH AN OUTPUT CIRCUIT SHALL BE SIZED IN ACCORDANCE WITH CEC <br />2013. <br />11. PHOTOVOLTAIC SOURCE ciRCUITS, OUTPUT CIRCUITS, INVERTER OUTPUT <br />CIRCUITS AND EQUIPMENT SHALL BE PROTECTED IN ACCORDANCE WITH <br />THE REQUIREMENTS OF THE CEC 2013. <br />12. MODULE FRAMES AND RACKING SYSTEMS SHALL BE GROUNDED AT <br />UL-USED LOCAnON PROVIDED BY THE MANUFACTURER USING UL USED <br />GROUNDING LUGS. THE REMOVAL OF ONE PANEL- SHALL NOT INTERRUPT <br />THE CONTINUITY OF THE GROUNDING SYSTEM FOR THE REST OF THE <br />PANELS OR RACKING SYSTEM. CEC 2013 <br />13.ALL CEC REQUIRED PV SIGNAGE (690.17, 690.53, 690.56, <br />705.10) WILL BE POSTED. <br />14.ALL GROUNDING ELECTRODES SHALL COMPLY WITH <br />REQUIREMENTS CEC 250.32 <br />DC (STC) RATING: 5.5kW <br />(22) SMX CAPITAL: SMX250P, 250 WATT MODULES <br />(1) SMA AMERICA: SB-5000TL-US-22 INVERTER <br />PV SYSTEM CALCULATIONS: <br />DC SIDE <br />MAXIMUM DC SYSTEM VOLTAGE: <br />37.91V x 11 x 1.12 = 467.1V <br />MAXIMUM PER DC SOURCE CIRCUIT CURRENT: <br />8.84A x 125% x 125% = 13.8A <br />AC SIDE <br />MAXIMUM AC SYSTEM VOLTAGE: 240V <br />MAXIMUM AC TOTAL SYSTEM CURRENT: <br />22 x 1.25= 2UA <br />MODULE INFORMATION: <br />SMX CAPITAL SMX250P, 250W <br />PEAK POWER: 250 WATTS <br />Voc: 37.91 Vdc Isc: 8.84A <br />Vpm: 30.11 Vdc Imp: 8.30A <br />MAX SERIES FUSE RAnNG: 20A <br />INVERTER INFORMATION <br />SMA AMERICA: SB-5000TL-US-22 <br />Compliance: IEEE-1547, UL 1741. <br />DQ <br />DC MAXIMUM VOLTAGE - 600V <br />MAXIMUM INPUT CURRENT -30A/15A PER MPPT <br />PEAK POWER TRACKING VOLTAGE-175-480V OP(125V--500V) <br />PV START VOLTAGE - 125V <br />AC <br />MAXIMUM OUPTUT POWER - 5000 wotts <br />OPERATING RANGE, UnUTY VOLTAGE - 211 - 264V @ 240V <br />MAXIMUM CONRNUOUS OUTPUT CURRENT - 22A @ 240V <br />FREQUENCY OPERATING RANGE - 60 Hz / 59.3 - 60.5 Hz <br />MAXIMUM EmCIENCY - 97.1% @ 240VAC <br />THE OPPOSITE (LOAD) END FROM THE INPUT <br />FEEDER LOCAnON OR MAIN CIRCUIT LOCAMON <br />SIGNAGE <br />NOTES: <br />ALL LABELS WILL BE ON RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. <br />ALL LABELS SHALL HAVE A RED BACKGROUND WITH WHITE LETTERING. <br />0 0 <br />WARNING SOLAR <br />PHOTOVOLTAIC CONNECTION DUAL VOLTAGE SYSTEM AC DISCONNECT <br />PHOTOVOLTAIC CONNECTED <br />DUAL VOLTAGE SYSTEM <br />RATED AC OUTPUT CURRENT:RATED AC OUTPUT CURRENT, <br />22 AMPS 22 AMPS <br />NOMINAL OPERATING AC VOLTAGE:NOMINAL OPERATING AC <br />240 VOLTS VOLTAGE: <br />240 VOLTS <br />SOLAR BREAKER ® <br />DO NOT RELOCATE PV Solar DC Disconnect <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED THE LOAD SIDES MAY BE ENERGIZED <br />TERMINALS ON BOTH THE LINE AND <br />IN THE OPEN POSITION <br />@ <br />OPERATING CURRENT•16.6A <br />WARNING OPERATING VOLTAGE,33121V <br />ELECTRICAL SHOCK HAZARD. THE DIRECT CURRENT <br />aRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC MAXIMUM SYSTEM VOLTAGE, 467.1V <br />POWER SYSTEM ARE UNGROUNDED BUT MAY BE SHORT CIRCUIT CURRENT,22.lA <br />ENERGIZED WATH RESPECT TO GROUND DUE TO <br />LEAKAGE PATHS ANQZOR GROUND FAULTS. <br />» r-LU C- <br />LOAD CALCULATIONS <i< <br />120% OF 200A = 240A 5 <OPV INPUT BREAKER = 30A J 0<£MAIN BREAKER UTILITY = 200A <br />TOTAL SUPPLY AMPS = 30A + 200A = 230A »c/i zCo<C <br />LO <br />TO BE PLACED ON ALL INTERIOR & EXTERIOR CE (\1<DC CONDUITS, RACEWAYS, ENCLOSURES, CABLE h 1- <br />ASSEMBLES, EVERY 10 FEET, AT TURNS AND 11 Z <br />ABOVE AND BELOW PENETRATONS AND ALL 15 4 <br />DC COMBINER AND JUNCTION BOXES Z 0 <br />CAUTION: SOLAR ELECTRIC < <br />SYSTEM CONNECTED & QC <br />1.LENERGIZED <br />® <br />IF A GROUND FAULT IS INDICATED, THE NORMALLY <br />GROUNDED CONDUCTORS MAY BE ENERGIZED AND <br />UNGROUNDED <br />Issue Date <br />3-10-2014 <br />Drawing <br />1-LINE <br />Sheet No. <br />PV-4
The URL can be used to link to this page
Your browser does not support the video tag.