VUNCI &ASSOCIATES <br />Structural Engineers <br />CUENT: <br />Professional Solar Products, Inc. <br />1551 S. Rose Ave., 0*nard, CA 93033 <br />Tel: 805·486·4700 <br />Subject Static load test results for the following: <br />Maximum Frame Maximum Frame Load Equivalent Wind SpeedMounng System Length' On.)Width' (In.)(lbs/ftl (mph)** <br />Roomace 65 40 50 125 <br />TEST SETUP (as shown in attached crawingdetail): Three modules, as specified above, were bolted to 136"xl.5')(25' <br />Professional Solar Products (PSP) patented RoofTrace support rails using an assembly of 5/16' Stainless Steel (SS) bolts, <br />SS lock washers and proprietary PSP aluminum damps and inserts. The Rooffrac® support rail was attached to the PSP <br />RoofTrac® structural atiachmentdevice with 3/8* SS hardware at four attachment points. The setup was attached to 2",(6" <br />wooden rafters using 5/16' x 3,1/2- SS lag bolts. The attachmentspans consisted of 48- frontto rear with structural <br />attachments spaced 72- on center. <br />TEST PROCEDURE(asshown in attached drawlngdetall): The test set up was top loaded to 50 lb/fti The setup remained <br />loaded for an approximate period of 30 minutes. The maximum deflection and any signs of permanent deformation were <br />recorded. The testsetup was then inverted and loaded to simulate the uplift condition. The test set up was re-loaded to 50 <br />lb/ft*. The setup remained loaded for an approximate period of 30 minutes. The maximum deflection and anysigns of <br />permanent deformation were recorded. <br />TEST RESULTS: <br />The maximum top load deflection was recorded at 0.313", with no permanent deformation. <br />The maximum uplift deflection was recorded at 0.250-. with no permanent deformation. <br />This document cerUfles the Roofrrac® mounting system used with the modules, as specified above, withstands a 50 lb/ft* <br />static pressure load, equivalent toa wind speed of approximately 125 mph'*. The mountingsystem performed as expected. <br />Sincerely, <br />James R. Vinci, S.E. <br />This en*leering report vellfiesthat Vinci & Assoclates has provided kndependent obse,vatlon for loed testing as described in tils report The results of this <br />load test,eflect actual deflection valuesand are generally accepted as the industry standard for testing module mounting systems. Vinci & Associates does <br />notfield check instalations orveri6 thatthe mountlngsystem Is installedas described in this en0neeringreport <br />Toassist thebuilding Inspector In verifyingtheauthenticity of this propriatary mounting swem, a permaneondhesion, <br />silver reflective -RoofTrace-label, asshown, is placed on at teast one of the maln support ralls or perma[Anly stampedwith 'Prof=lonal Solar Prod. Pat 6.360,491- on the (Roof#29,)undergide ofraiL 1 <br />Structural attachment Lagboltattachmentshould belnstalled <br />using Ule proper pilot holefbr optimum strength. A 5/16 'ag <br />bolt requires a 3/16' pilot hole. tt Is the responsibility of the <br />inotoller to Inoure o proper attachmantls made to the structural memberof the roof. Pal kie to <br />securely attach b the roof structure may result in damage to equipment. pemonal Intuly of property <br />damage. <br />This office does notexpress an opinion as to the load bearingcharactenstics of thestructure the <br />mounting systenvmodules am beinglnstaled on. <br />1CC accredited laborato¥tested structural attachments manufactured hy Professlonal Solar Products <br />(including but not limited to Fastjack• . TileTrace, and Foamlacf) can beinterchanged with 0,18 <br />s)stern. <br />Checkwith local buildingdepartment or AHJ for site specific requirement, <br />*Modules measuring within stated specifications and tested to UL1703. orequivalent, are included <br />in this ent#neering <br />.. Wind loadingvalues relativetodefined load values using wind load exposure (125 mph for 5/12 <br />roof pitch or less; 100 mph for greaterthan 5/12 roof pitch) and gust factor coefficient 'exposure C' <br />es defined M the 2009(IBC)/2010(CBC) <br />***Moduletested: 64.8- x 39.4- x 1.7' (sln) <br />•***Est gnow load ratingof 25 le/ft' based on 2.0 safely factor <br />Thousand Oaks, CA 91382 <br />Page 1 of 2 <br />4 720 1 <br />3 <br />4t <br />Module <br />Area = <br />18 ft? each >0<--1 1 <br />-A| Approx 20' max |.-04 rhang 40' <br />Total module (45 lbs ea.) <br />and rail (12 lbs ea.)weight 159 lbs <br />Numberof attachments: 4 ea <br />Weight / attachment point 40 lbs <br />Area:54 ff <br />Distributed weight:2.95 IW ff <br />11 <br /> 2.710 lbs /50 psf <br />1-1 U <br />5/16" Stainless Top Load Deflection: 0.313" <br />Steel Hex bolt <br />2,710 lbs / <br />50 psf <br />511 6-Stainless Steel <br />4= - Lock Washer <br />1 <br />0 + <br />1117.-11.0+Ree eU.4.T <br />Dia <br />i <br />. Aluminum ProSolar Inter-Module Clamp LI LI <br />Up lift Deflection: 0&801- Aluminum ProSotar Wl)1 - Rail nut <br />y! <br />, 2-1/2- Aluminum ProSolar <br />Roofrrao® Support Rail <br />, 3/8" Stainless Steel Hex <br />Bolt and Flat Washer <br /> Aluminum ProSotar patented <br />FasUack® Roof Attachmene <br />5/16" Stainless Steel Lag Bolt <br />and Flat Washer <br />tab tested structural attachments manufachred by Professional Solar Products <br />{Including Fastlack® , TileTrac®, and FoarnJacks) can be Interchanged with thts system. <br />Proless)onal Sokr Products Roofrrad' Patent# 6,360,491 <br />Photovoltalc mounting system <br />RoofTrac® <br />V <br />Solar Modules <br />Static load test illustration <br />Page 2 of 2 RT_6