My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180923_1418 W. RIVER - Plan
PBA
>
Building
>
Plans
>
R
>
River Ln
>
1418 W River Ln
>
10180923_1418 W. RIVER - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 12:52:43 AM
Creation date
10/25/2020 5:21:21 PM
Metadata
Fields
Template:
Plan
Permit Number
10180923
Full Address
1418 W River Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
amelrican2 3 4 5 6 1 8 9 10 GENERAL NOTES 14. <br />1. SOLAR PWOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE.LJ Sol•r Direct <br />LEGEND PROJECT DEVELOPER: <br />2. DESIGN COMPUES WITH THE 2013 EDITION OF THE CRC,AND 2011 NEC, AND ALL LOCAL American Solar Direct IR- - <br />UCENSE 81010/046#9410691 RJUNCTION BOX ORDINANCES AND POLICIES.©2010 AMERICAN SOLAR DIREC"l:INEW Ati <br />11766 WILSHIRE BLVD.. SUITE 500 <br />LOS ANGELES CA80025 ··69* <br />3. THIS PROJECT HAS BEEN DESIGNED IN COMPUANCE WITH THE CmC SECTION Ieee TO PH: (424)214-8700 tat ¢INvERTER WITH INTEGRATED DC DISCONNECT FX {424) 214·6750 <br />WITHSTAND A MINIMUM Ile MPH UJIND LOAD.21,1: ENG)aRD,oAER£•SOU,=RECT.COM <br />-1 WEB: hnpl#imimi,gil/0320!mdirectcom <br /> PHOTOVOTAC LOADCENTER <br /> PV GENERATION METER <br /> Pv SYSTEM DISCONNECT UTIUTY OPERATION <br /> MAIN PANEL BOARD <br />) INVERTER-STRING <br />PLUMSING VENT, 4" <br />MIN. DISTANCE TO <br />SOLAR PANEL <br />RE-ROUTE - <br />(2) PLUMBING <br />vENT <br />4 THIS SYSTEM WILL NOT SE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION <br />AND THE UTIUTY 16 OBTAINED. <br />THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. <br />IF THE E>OSTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, <br />IT 16 TWE CONTRACTOR'S RESPONSIBIUTY TO INSTALL A SUPPLEMENTAL COPPER GROUNDING <br />ELECTRODE. <br />-*121 <br />:Iffe 10 <br />4.1.1 <br />1*Ut Wi <br />SOLAR MODULES, <br />SEE SHEET PV-2 FOR <br />STRUCTURAL INFORMATION <br />FOR CONNECTION TO <br /> STRUCTURE SEE DETAIL <br />CH <br />EACH MODULE UJILL DE.GROUNDED USING THE SUPPUED CONNECTION POINTS IDENTIFIED ON <br />THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />a. REFER TO SHEET E.3 FOR SIGNAGE "CAUTION: SOLAR CIRCUIT" STICKER TO BE INSTALLED <br />EVERY 5 FEET AND Se DEGREE BENDS OF CONDUIT. <br />9. ALL CONDUIT TO RUN ON THE EXTERIOR OF THE HOUSE (NO CONDUIT TO BE INSTALLED IN ATTIC <br />SPACE). <br />/ >30 <br />le. SOLAR PANELS SMALL BE INSTALLED WITH NO PORTION MORE THAN la INCHES ABOVE TWE <br />ROOF IMMEDIATELY BELOW. <br />11,34e THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS OR SOLAR vOLTAIC ROLL ROOFING <br />MATERIAL SHALL HAVE THE SAME OR BETTER USTED FIRE-RESISTANCE RATING THAN THE <br />BUILDING ROOF-COVERING MATERIAL <br />V ................1 <br />e <br />0 <br />PL <br />GV <br />12. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT 8.251<W PV <br />RIDGE --PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. <br />THE BONDING CONNECTION BETWEEN TME GROUNDING ELECTRODE CONDUCTOR ANC) THE <br />SHEET TITLE. <br />,1 (E) 2-STORY <br />GV MOUSE <br />0 <br />PL <br />SL SL <br />DIMENSIONS AND Az: sam <br />STRUCTURAL INFORMATION - <br />FOUND ON PV.2 \41 <br />23© SLOPE <br />ROOF PLAN <br />CHIEF ELECTRICIAN <br />DANNY McINTYRE <br />DI,cINTYREGAMER1C,NSOCARDIRECT.COM <br />(424) 214-6700 <br />Signature- Danny Mcintyre <br />LICENSE B/C10/C46 #941069 <br />--e <br />P <br />J <br />I Ul:6 C <br />.g -1 <br />W li"\U. <br />:..1 <br />-1 <br />3'-9 3'-e <br />\1/ <br />1'-6 <br />34/ <br />13. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR <br />PANEL SHALL BE ACCESSIBLE DIRECTLY OR EY DISPLACEMENT OF MODULECS) OR PANELCS) <br />SECURED el- REMOVABLE FASTENERS. <br />14. ONE- AND TWO-FAMILY DWELLINGS, UVE PARTS IN Pv SOURCE CIRCUITS AND Pv OUTPUT <br />CIRCUITS OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUAURED <br />PERSONS WHILE ENERGIZED. <br />15. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL SE PERMITTED <br />TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. <br />le. "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED" LABEL SHALL BE LOCATED ON MAIN <br />AZ: 21010 SERVICE PANEL <br />230 SLOPE <br />ABBREvIATIONS <br />AZ AZIMUTH <br />CE)EXISTING <br />CLR.CLEARANCE <br />MIN.MINIMUM <br />PV.PHOTOVOLTAIC <br />ROG.RIDGE <br />FIRE CLEARANCE - <br />3'-e" MIN. SPACING <br />FROM TOP OF RIDGE <br />AND GABLE. 1'-6" MIN. <br />SPACING FROM HIP <br />AND VALLEY. <br />VALLEY <br />GAS VENT * <br />PLUMBING VENT O <br />AIR VENT 1521 <br />/ AP <br />\ <br />(N)2OOA <br />ELECTRICAL <br />- EXISTING <br />COMPOSITE <br />ROOF <br />PV CONDUIT - <br />Hi21 EXTERIOR <br />(PAINTED TO MATCW <br />EXISTING COLOR) <br />PROJECT BREAKDOWN <br />SYSTEM SIZE: 8.25KW SYSTEM (33) RENESOLA JC25erl-24/Be SOLAR MODULES <br />IN (1) STRING OF 16 MODULES ON (1) SOLAREDBE INVERTER MODEL: SESSeeA-lIe (24ev) ¢ <br />IN (1) STRING OF 11 MODULES ON 0) SOLAREDGE INVERTER MODEL: SE38eeA-lIe (24ev) <br />City Revision/lsgue Date <br />THIS DRAWING IS PROPERTY OF <br />AMERICAN SOLAR DIRECTING. THIS <br />DRAWING IS CONFIDENTIAL AND IS <br />ONLY TO BE USED IN CONJUCTION <br />WTTH WORK DESIGNATED BY <br />AMERICAN SOLAR DIRECT INC. NO <br />PART OF ™IS DOCUMENT IS TO BE <br />DISCLOSED TO OTHERS WrrHOUT <br />THE PRIOR WRITTEN PERMISS]ON <br />OF AMERICAN SOLAR DIRECT INC. <br />SERVICE <br />ROOF PLAN SCALE= 3132" <br />MOUSE HEIGHT:2-STORIES CAD Revisions <br />RAPTER SPACING:2 X e @ 24" O. C. JEC-CAF/2.19.14 <br />ROOF MATERIAU COMPOSITE JS/PS/03/11/14 <br />BACKING SYSTEM:SNAP N RACK <br />- ROOF AREA:2136.39 SQ. FT Scolo·Sheet <br />TOTAL AREA COVERED El- PHOTOVOLTAIC ARRAY:21 % pots:Pvt <br />el <br />m <br />0 <br />0 <br />ill <br />KL <br />'5 <br />I <br />1.
The URL can be used to link to this page
Your browser does not support the video tag.