Laserfiche WebLink
JGALVAhJED 21/2.x 12·x 7 GAGETHICK <br />1 STEEL STRAP W/4-5/8'0 LAGS -APPROVED CAP <br />y <br />3172· <br />457 <br />P .4 4'xi POST MINIMUM t <br />1G- i - <br />4·x4' <br />A <br />POST--0- 5-BD NAILS. <br />4'x BEAM -EACH END <br />/ /1 4-x BEAM <br />2.- PLL,/I BRACE w <br />4·x 'KNEE b /f /\ <br />I 2-1 /2' 0 x 5' LONG LAGS SCREWS: <br /><1 EACH END <br />1(SEE DETAIL •E•) <br />- 1·%6· KNEE <br />BRACE <br />DETAIL "B"DETAIL "B:" ALTERNATE <br />STANDOFF 1 .-1 0 <br />ISTAND-OFF - -1' STAND-OFFAPOST/ IBASE- r*>1 <br />r 4'x BEAM12• <br />AN6HOR L 1- 1 -- - ++1 <br />EMBEDI . <br />ANCHORS IN 1--_ <br />CONCRETE 1 : <br />> 17-7.BOLT <br />31/20 <br />i \%\ IGALVANIZED <br />912'x12'x7 GAGE <br />1•r W/6-5/8' 0 LAGS <br />3- 4"x POST <br />GRADE-' <br />DETAIL "C"--1 <br />DETAIL "D" <br />NOTES: <br />1. ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BENEW <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />2. ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br />CODE CURRENTLY IN EFFECT. <br />3. CONCRETE SLAB TO BE-MINIMUM 31/2" THICK. <br />4.· POSTS SHALL BE MINIMUM 4'x4 <br />5. BOTTOM OF POSTS SHALL BE ONE INCH (1") ABOVE SLAB. <br />6. ROOF SHEATING SHALL BE: <br />a. 1/2' PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T &+G <br />STRUCTURAL I, WITH 10 d AT 6" O/C AT SUPPORTED ENDS, AND12° O/C ALONG <br />INTERMEDIATE FRAMING MEMBERS, OR <br />b. 1 " BOARD SPAN 32"; 2" SOLID T&G SPAN 8'-0'; 2"x2¤ SELF-SPACED SPAN 600" <br />7. iROOFING SHALL BE MIN. CLASS 'C" ROOF COVERING (CBC TABLE 1505.1) OF: <br />a. WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUILT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4"/FT.) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSIRUCTIONS. - - - <br />8. MAXIMUM HEIGHT FOR A PATIO COVER lS TWELVE FEET. <br />9. PATIO COVER SHALL BE USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br />PURPOSE AND NeTAS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />10. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WALLAND ONE ADDITIONAL WALL IS EQUALTO AT LEAST SIXTY- <br />FIVE PERCENT·OF THE AREA BELOW A MINIMUM-OF 6'-8" OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />11. OPENINGS MAYBE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br />READILY REMOVABLE. TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br />1/8 INCH IN THICKNESS. <br />12. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER, <br />13. PATIO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />- 444'KNEE BRACE <br />l <br />2-1/2" 0'*5· LONG LAG SCREWS <br />42!POST <br />DETAIL "E" <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />TURIWI 6-in P K 6-UYEd 3-19-/4 <br />PRINT NAME /SIGNATURE DATE <br />rev: 07/19/2011 Page 2 of 2