Laserfiche WebLink
*-SANTA <br />NA <br />lLt\INC <br />fiX[U[\-C <br />ltl\fi <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-s800 <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />soL-01 cBc 2013 <br />solar Photovoltaic (PV) checklist for Detached sINGLE FAMILy RESTDENCES onry <br />Instructions: The licensed contractor of record shall com plete all sections, answer the ten questions andsign the certification section below. A copy of this form sh all be attached to each of TWO sets of plans, ofminimum 11" x 17' size. lf answerinq NO to an y of the questions.plan check sha ll be re quired. <br />Proj ect Address: H LL v-le"YOC <br />c<Contractor Company Name: <br />Contractor License Number: <br />YES NO <br />&tr <br />q 4D/{2_ <br />Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605. 11 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10,, maximum between <br />the underside of modutes and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter_we ight <br />system? <br />2 <br />3 <br />Eg <br />Ettr <br />4aEO <br />ho <br />Ftr <br />f,a <br />?tr <br />?a <br />4 <br />6 <br />7 <br />8 <br />I <br />Will the anchors be installed with a maxjmum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a mjnimum ol 2-112inch <br />embedment lnto roof rafters (with pre-drifled hores) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans stamped and signed by a California <br />licensed professional engineer? (including proiect specific site plan, pV layout, <br />anchorage spacing, anchorage details and manufacturer's pV support information.) <br />'10 <br />Print Name: <br />Phone Num <br />Email Address <br />I certify under penalty of perjury under the laws of the State of California that the above is true:\r Signature <br />5't-o.1 <br />Rev 11/'19/2015 <br />rJi <br />€@ <br />Date <br />.co