My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180969_2606 N. DEODAR - Plan
PBA
>
Building
>
Plans
>
D
>
Deodar St
>
2606 N Deodar St
>
10180969_2606 N. DEODAR - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2021 8:34:20 AM
Creation date
10/25/2020 5:21:59 PM
Metadata
Fields
Template:
Plan
Permit Number
10180969
Full Address
2606 N Deodar St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
' Cd pool <br />engineering <br />- inc. <br />POOL ENGINEERING INC.By: R. McPherson <br />Location: Santa Ana, CA,92705-1766 Date: 3/20/2014 <br />Job# 14-0458 <br />PROJECT DATA: <br />Proiect Location: <br />2606 Deodar St <br />Santa Ana, CA,92705-1766 <br />Existina Residence: <br />Roof Area:2200 ff <br />Upper Floor Area:N/A <br />Lower Floor Area:NA <br />Number of Stories: 1 <br />Site Propenies: <br />Latitude: 33.772 <br />Longitude: -117.83 <br />Ss = 1.4937 (g) 0.25 Spectral Response Acceleration <br />Sl = 0.546 (g) 1.Os Spectral Response Acceleration <br />Site Class: D (ASCE 7-10, Section 11.4.2) <br />Fa = 1.00 Site Coefficient (ASCE 7-10, Table 11.4-1) <br />Fv = 1.50 Site Coefficient (ASCE 7-10, Table 11.4-2) <br />SDs = 0.9958 Short Period Design Spectral Acceleration Parameter (ASCE 7-10, Eqn. 11.4-3) <br />SD1 = 0.5460 ls Period Design Spectral Acceleration Parameter (ASCE 7-10, Eqn. 11.4-4) <br />Wind Speed = 110 mph (basic wind speed) <br />Exposure Category: C <br />Product Information: <br />Manufacturer: PHONO SOLAR <br />Model: PS300P-24/T <br />Weight:2.92 p.s.f. (including mounting system) <br />Installed Area: 209.08 ft2 <br />Design Criteria: <br />C.B.C. 2013 <br />ASCE 7-10 <br />Design Methodologv: <br />Per the exception in Section 3403.4 of the C.B.C. 2013: <br />"Any existing lateral load-carrying structural element whose demand-capacity ratio with the addition considered is no more than 10 percent greater than <br />its demand-capacity ratio with the addition ignored shall be permitted to remain unaltered" <br />This calculation will verify whether or not the increased loads imposed by the addition, will result in an increase of 10% or less of a demand in <br />the existing structure. If ithe demand increase is within 10% of the original demand-capacity ratio, no retrofit shall be required. <br />3/20/2014 3:31 PM <br />\\peanasv2\Pool\Projects Solar\2014\0458-14 Residential\14-0458 SOLAR PANEL CALCS.xlsx <br />Page 7 of 13 <br />©Pool Engineering, Inc. 2014
The URL can be used to link to this page
Your browser does not support the video tag.