Laserfiche WebLink
91 SIGN COMPONENTS MANUAL (SAM)October 1, 2013 <br />3. When these units are connected to a Class 2 supply circuit, they are not to draw a total wattage of greater than the secondary or <br />output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means available. <br />LED Modules, Models LS-0767, LS-MZ0609, LS-MZ0612-2 and LS-MZ0612-3. <br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. <br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy <br />limited circuits. <br />3. When these units are connected to a Class 2 supply circuit, they are not to draw a total wattage of greater than the secondary or <br />output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations. <br />5. These products are not required to be endosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means available. <br />LUMIFICIENT CORP <br />8752 MONTICELLO LN NORTH <br />E230262 <br />MAPLE GROVE, MN 55369 <br />Class 2 LED Modules, HRL-06-PFC-96, HRL-08-PFC-96-BMA, HRL-xx-PFC-96yy, where )0< denotes 06 original model or 07 <br />Alternate constructions, where yy denotes BM for the use of the CBI circuit breaker Model No. (BFQ1 PA-B07XC-0500X), Class 2 <br />Power Unit. Model HYPERION R-Lite System-LED tape. Model HLR-PC power connector. Model HRL-IDC Power IDC connector. <br />1. The power units were submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40(C. <br />2. The HRL-06-PFC-96 power unit is provided with a conduit fitting suitable for 1/2 in. Trade Size rigid nonmetallic conduit. <br />3. The HRL-06-PFC-96 power unit, HRL-=-PFC-96yy and HRL-08-PFC-96BMA, HYPERION R-Lite System-LED tape, HLR-PC <br />power connector, and HRL-IDC Power IDC connector are suitable for dry or damp locations <br />4. Temperature test at 40(C, Inputs and Dielectric test was conducted. The need for additional test shall be determined in the end <br />used product. <br />5. The Model HRL-08-PFC-96BMA power unit is provided with a 1/2 in. Trade Size conduit opening. <br />Class 2 LED modules Model HYPERION R-Lite System-LED tape, Model HLR-PC power connector, & Model HRL-IDC Power <br />IDC connector. <br />1. The power units were submitted and tested for a maximum manufacturets recommended ambient (Tmra) of 40°C. <br />2. The HRL-06-PFC-96 power unit is provided with a conduit fitting suitable for 1/2 in. Trade Size rigid nonmetallic conduit. <br />3. The HRL-06-PFC-96 power unit, HRL-xx-PFC-96yy and HRL-08-PFC-96BMA, HYPERION R-Lite System-LED tape, HLR-PC- <br />200 power connector, HRL-JC-200 jumper connector and HRL-IDC-B Power IDC connector are suitable for dry or damp <br />locations <br />4. Temperature test at 40°C, Inputs and Dielectric test was conducted. The need for additional test shall be determined in the end <br />used product. <br />5. The Model HRL-08-PFC-96BMA power unit is provided with a 1/2 in. Trade Size conduit opening. <br />LED Driver; Cat. No. Model HRL-06-PFC-24, HRL-=-PFC-24yy where = denotes 06 original model or 07 Alternate <br />constructions, where yy denotes BM for the use of the CBI circuit breaker Model No. (BFQ1 PA-B07XC-0500X), Class 2 Power <br />Unit. <br />1. The HRL-06-PFC-24 power unit was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of <br />40(C. <br />2. The HRL-06-PFC-24 power unit is intended for installation inside an electrical enclosure. Minimum spacing between adjacent <br />power units is 4 in. <br />3. The HRL-06-PFC-24 power unit is suitable for dry or damp locations. <br />Class 2 LED module, designated as Hyperion R2, Cat. No. HR2-XXXX, where XXXX may be replaced with any alphanumeric <br />characters. <br />1. These products are only suitable for connection to a LPS or Class 2 power source rated 24 Volt AC or less. <br />2. These products are each rated max. 2.4 watts per module. When units are connected to a Class 2 circuit, they are not to draw a <br />total wattage of greater than the secondary or output rating of the Class 2 supply. <br />3. These products are suitable for use in dry and damp locations with supply sources rated at 24 Volts AC or less. <br />4. These products may be secured in place in the end product by any means available. <br />Class 2 LED Modules, designated as H-Lite-XXXX series, E-Lite-XXXX series, E-Lite-YYY series, where XXXX may be any <br />numeric characters and YYY may be any alpha characters. <br />1. These products are only suitable for connection to a Class 2 power source rated 8 Volts AC or DC or less. <br />2. When units are connected to a Class 2 circuit, these products are not to draw a total wattage of greater than the secondary or <br />output rating of the Class 2 supply. <br />4. These products are suitable for use in dry, damp or wet locations. <br />5. These products may be secured in place in the end product by any means available. <br />Sign Accessories, Transformer, Class 2 Inherently limited, Model HRL-PSLP-13 and Transformers Class 2 Non-Inherently limited <br />Models HRL-PS277-70, HRL-PS96-70, and HRI--PSSQ-25-T. <br />1. These LED Transformers have been evaluated to Class 2 output requirements for AC circuits with a maximum of two Class 2 <br />output. <br />2. These products are provided with the following electrical ratings: <br />Max. <br />Input <br />Model Input Volt HZ Amps Watts V(ac)Current A VA/Output #of Output <br />HRL-PSLP-13 120 50/60 0.175 21 8.3 2.0 17 (1) <br />HRL-PS277-70 277 50/60 0.347 94 8.5 5.0 42.5 (2)