My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2740 S Bristol St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
2740 S Bristol St
>
2740 S Bristol St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 5:03:19 AM
Creation date
9/17/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101123931
Full Address
2740 S Bristol St
Street Number
2740
Street Direction
S
Street Name
Bristol
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY <br />ARE ACTING UNDER THE DIRECTION OF A LICENSED <br />PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. <br />REV DATE DESCRIPTION <br />PROJECT NO: <br />DRAWN BY: <br />CHECKED BY: <br />SHEET TITLE <br />SHEET NUMBER <br />UTILITY ACCEPTANCE STAMP <br />0 05/16/2025 ISSUED FOR PERMIT <br />XXXX <br />MP <br />MP <br />2740 SOUTH BRISTOL ST <br />SANTA ANA, CA <br />ELECTRICAL VEHICLE <br />CHARGING STATIONS <br />S1.0 <br />STRUCTURAL DETAILS <br />REALTY 2740 <br />BRISTOL LLC <br />NO SCALE 1 <br />NO SCALE 8 <br />6 <br />2 3 <br />4 <br />7SWITCHBOARD CONCRETE PAD DETAIL <br />5 <br />FRONT SIDE <br />SCALE: 12" = 1'-0" <br />℄ <br />℄ <br />℄ <br />℄ <br />(12) 3/8" DIA. HILTI KWIK BOLT TZ2 SS 304 <br />ANCHORS WITH MIN. EFF. EMBEDMENT OF <br />2.5". LOCATION PER SWITCHBOARD MFR. <br />SPEC'S. <br />12'-4" <br />4' <br />- <br />9 <br />" <br />6" MIN <br />TYP. <br />6" <br /> <br />M <br />I <br />N <br />TY <br />P <br />. <br />SWITCHBOARD PER <br />ELECTRICAL PLANS. <br />PLAN <br />REBAR NOT SHOWN <br />FOR CLARITY. <br />GRADE <br />2" CLR. <br />GRADE <br />2" CLR. <br />#6 @ 12" O.C. TOP & <br />BOTTOM, EACH WAY <br />#6 @ 12" O.C. TOP & <br />BOTTOM, EACH WAY <br />TOP OF <br />FTG. <br />12 <br />" <br />2" <br />3"CL <br />R <br />. <br />TOP OF <br />FTG. <br />12 <br />" <br />2" <br />3"CL <br />R <br />. <br />6" MIN. 95% <br />COMPACTED <br />BACKFILL. <br />6" MIN. 95% COMPACTED BACKFILL. <br />SWITCHBOARD PER <br />ELECTRICAL PLANS. <br />SWITCHBOARD PER <br />ELECTRICAL PLANS. <br />NOT USED <br />PLAN <br />31-3/8" <br />29 <br />- <br />1 <br />/ <br />2 <br />" <br />86 <br />- <br />5 <br />/ <br />8 <br />" <br />31-3/8" <br />86 <br />- <br />5 <br />/ <br />8 <br />" <br />29-1/2" <br />FOUNDATION PER <br />DETAIL 2 ON THIS <br />SHEET. <br />TITAN 320KW <br />LEVEL 3 CHARGER. <br />DUAL PORT EV CHARGER DETAIL (EVC LEVEL 3)SCALE: 12" = 1'-0"DUAL PORT FOUNDATION DETAIL (EVC LEVEL 3) <br />℄ <br />℄℄ <br />4'-0" <br />3' <br />- <br />6 <br />" <br />(6) 3/8" DIA. HILTI KWIK BOLT TZ2 SS 304 <br />ANCHORS WITH MIN. EFF. EMBEDMENT OF <br />2.5". LOCATION PER MFR. SPEC'S. <br />REBAR NOT SHOWN <br />FOR CLARITY. <br />LEVEL 3 DUAL PORT <br />CHARGER BASE. <br />GRADE <br />TOP OF <br />FTG. <br />12 <br />" <br />3" <br />2"2" CLR.TOP OF <br />FTG. <br />12 <br />" <br />2" <br />GRADE <br />2" CLR. <br />#6 @ 12" O.C.#6 @ 12" O.C. <br />6" MIN. 95% <br />COMPACTED <br />BACKFILL. <br />CL <br />R <br />. <br />3"CL <br />R <br />. <br />6" MIN. 95% <br />COMPACTED <br />BACKFILL. <br />PLAN <br />℄ <br />CONCRETE BOLLARD DETAIL NO SCALE REMOVABLE BOLLARD DETAIL NO SCALE <br />NO SCALE <br />3" <br />9/ <br />1 <br />6 <br />" <br />SAFETY LOCK <br />(CODE 170116) <br />WELD, TYPICAL, WILL <br />BE PAINTED OVER <br />WITH A ZINC PRIMER <br />EYE BOLT, 1/2" x 6", <br />STEEL GALVANIZED <br />(TO BE INSTALLED <br />PARALLEL TO EDGE <br />OF PAD) <br />CUT FROM 1/2" x 6" <br />EYE BOLT, STEEL <br />GALVANIZED <br />DETAIL A <br />32 <br />" <br /> <br />M <br />I <br />N <br /> <br />- <br /> <br />3 <br />3 <br />" <br /> <br />M <br />A <br />X <br />6" <br />± <br />3 <br />" <br />3" <br /> <br />M <br />I <br />N <br />4' <br />- <br />0 <br />" <br />12" MIN <br />END CAP <br />VISIBILITY <br />STRIPS <br />4" SCH 40 GALV <br />STEEL PIPE <br />5" SCH 40 GALV <br />STEEL PIPE <br />SLEEVE <br />CONCRETE <br />FOUNDATION <br />SEE <br />DETAIL A <br />3" <br />1'-9" <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />4' <br />- <br />0 <br />" <br />CONCRETE <br />EXISTIN <br />GRADE <br />SURFACE <br />4" GALVANIZED <br />SCHEDULE 40 <br />STEEL PIPE <br />FILL WITH <br />CONCRETE <br />VISIBILITY STRIPS <br />NOTES <br />1.PAINT BOLLARD WITH ONE PRIME COAT <br />AND TWO FINISH COATS. PRIME COAT TO <br />BE EPOXY ENAMEL (CARBOLINE "890" OR <br />EQUAL). THE FIRST FINISH COAT SHALL <br />BE EPOXY ENAMEL. THE SECOND FINISH <br />COAT SHALL BE ALIPHATIC <br />POLYURETHANE (AMERON <br />"AMERSHIELD" OR EQUAL). PRIOR TO <br />APPLYING PAINT, THE PIPE SURFACE <br />SHALL BE PREPARED IN ACCORDANCE <br />WITH COATING. <br />2.THE BOLLARD IS USED FOR WARNING <br />SIGN ONLY. IT IS NOT DESIGNED FOR <br />VEHICULAR BARRIER PURPOSE. <br />TRANSFORMER ANCHORAGE DETAIL <br />NOTE <br />1.MINIMUM 9" CONCRETE EDGE DISTANCE <br />REQUIRED FOR PROPOSED ANCHOR. <br />3/8" DIA. HILTI KWIK BOLT TZ <br />SS 304 MECHANICAL ANCHOR <br />W/ MIN. EMBEDMENT OF 2.5" <br />(OR APPROVED EQUAL). <br />HEAVY DUTY NUT <br />WASHER <br />2. <br />5 <br />" <br /> <br />M <br />I <br />N <br />. <br />CONCRETE <br />TRANSFORMER PAD <br />NO SCALETYPICAL EV LOGO DETAIL <br />4" WIDE WHITE <br />BORDER <br />PAINT SYMBOL AND BORDER <br />WITH WHITE REFLECTIVE PAINT <br />PAINT FIELD WITH <br />RELFECTORIZED <br />GREEN
The URL can be used to link to this page
Your browser does not support the video tag.