400 Sunrise Ave., Suite 270
<br />Roseville, CA 95661
<br />916.755.3571 / MiTek-US.com
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />Job
<br />25-0691-001
<br />Truss
<br />A04
<br />Truss Type
<br />MONOPITCH
<br />Qty
<br />1
<br />Ply
<br />2
<br />Raising Cane's #C1032
<br />Job Reference (optional)
<br />R89895392
<br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:01 2025 Page 1 Precision Truss, Citrus Heights, CA
<br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-EW2xLkwlrwPXtq8MHQdiuo3StrAS3JILmqmSVdyjuGe
<br />Scale = 1:50.8
<br />12 3 4 5 6 7
<br />14 13 12 11 10 9 8
<br />15
<br />16 17 18 19
<br />20
<br />21 22
<br />23 24 25 26 27 28
<br />4x6
<br />3x4
<br />4x10
<br />3x4 8x8
<br />3x6
<br />3x5
<br />8x8
<br />3x4
<br />3x4 3x10
<br />5x8
<br />LUS24
<br />LUS24
<br />6-3-9
<br />6-3-9
<br />12-3-10
<br />6-0-0
<br />18-3-10
<br />6-0-0
<br />24-3-11
<br />6-0-0
<br />30-7-4
<br />6-3-9
<br />6-3-9
<br />6-3-9
<br />12-3-10
<br />6-0-0
<br />18-3-10
<br />6-0-0
<br />24-3-11
<br />6-0-0
<br />30-7-4
<br />6-3-9
<br />2-
<br />9
<br />-
<br />1
<br />2
<br />2-
<br />4
<br />-
<br />4
<br />7-
<br />0
<br />-
<br />8
<br />3-
<br />5
<br />-
<br />5
<br />0.25 12
<br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [9:0-3-9,0-2-8], [10:0-4-0,0-4-8]
<br />LOADING (psf)
<br />TCLL
<br />TCDL
<br />BCLL
<br />BCDL
<br />20.0
<br />15.0
<br />0.0 *
<br />10.0
<br />SPACING-
<br />Plate Grip DOL
<br />Lumber DOL
<br />Rep Stress Incr
<br />Code
<br />2-0-0
<br />1.25
<br />1.25
<br />NO
<br />IBC2021/TPI2014
<br />CSI.
<br />TC
<br />BC
<br />WB
<br />Matrix-MS
<br />0.44
<br />0.70
<br />1.00
<br />DEFL.
<br />Vert(LL)
<br />Vert(CT)
<br />Horz(CT)
<br />Wind(LL)
<br />in
<br />-0.13
<br />-0.73
<br />0.12
<br />0.07
<br />(loc)
<br />10-11
<br />10-11
<br />8
<br />9-10
<br />l/defl
<br />>999
<br />>493
<br />n/a
<br />>999
<br />L/d
<br />360
<br />240
<br />n/a
<br />240
<br />PLATES
<br />MT20
<br />Weight: 407 lb FT = 20%
<br />GRIP
<br />220/195
<br />LUMBER-
<br />TOP CHORD 2x6 DF No.2 G
<br />BOT CHORD 2x6 DF No.2 G
<br />WEBS 2x4 DF Std G *Except*
<br />8-15: 2x6 DF No.2 G
<br />BRACING-
<br />TOP CHORD Structural wood sheathing directly applied or 5-4-15 oc purlins,
<br />except end verticals.
<br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
<br />REACTIONS.(lb/size)13=2116/0-2-11, 8=2335/0-5-8
<br />Max Horz 13=193(LC 9)
<br />Max Grav 13=2153(LC 29), 8=2483(LC 35)
<br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-13=-483/70, 3-17=-4627/0, 4-17=-4626/0, 4-18=-7934/0, 18-19=-7925/0,
<br />19-20=-7923/0, 5-20=-7923/0, 5-21=-7947/0, 6-21=-7936/0, 6-22=-4926/0,
<br />7-22=-4923/0, 7-8=-2448/0
<br />BOT CHORD 13-23=0/4625, 12-23=0/4625, 12-24=0/7881, 11-24=0/7881, 11-25=0/7976, 25-26=0/7976,
<br /> 10-26=0/7976, 10-27=0/4923, 9-27=0/4923
<br />WEBS 3-13=-4884/0, 3-12=0/1626, 4-12=-3741/0, 4-11=0/942, 5-11=-400/258, 5-10=-911/0,
<br />6-10=0/3501, 6-9=-1915/0, 7-9=0/5404
<br />NOTES-(15)
<br />1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
<br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
<br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
<br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
<br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
<br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
<br />3) Unbalanced roof live loads have been considered for this design.
<br />4) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed;
<br />MWFRS (envelope) and C-C Corner(3) 0-0-0 to 15-0-0, Exterior(2) 15-0-0 to 15-4-7, Corner(3) 15-4-7 to 30-4-7 zone; cantilever left
<br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
<br />DOL=1.33 plate grip DOL=1.33
<br />5) Provide adequate drainage to prevent water ponding.
<br />6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />will fit between the bottom chord and any other members.
<br />8) A plate rating reduction of 20% has been applied for the green lumber members.
<br />9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 13.
<br />10) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all
<br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads.
<br />11) Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d Truss) or equivalent spaced at 7-9-10 oc max. starting at 13-7-8 from the left
<br />end to 21-5-2 to connect truss(es) to front face of bottom chord.
<br />12) Fill all nail holes where hanger is in contact with lumber.
<br />Continued on page 2
<br />August 27,2025
|