400 Sunrise Ave., Suite 270
<br />Roseville, CA 95661
<br />916.755.3571 / MiTek-US.com
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />Job
<br />25-0691-001
<br />Truss
<br />A11
<br />Truss Type
<br />Monopitch
<br />Qty
<br />1
<br />Ply
<br />1
<br />Raising Cane's #C1032
<br />Job Reference (optional)
<br />R89895399
<br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:07 2025 Page 1 Precision Truss, Citrus Heights, CA
<br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-3gPCcn_VRm9gblcWehk673JM8GC4T3GD9mDniHyjuGY
<br />Scale = 1:50.8
<br />12 3 4 5 6 7 8
<br />16 15 14 13 12 11 10 9
<br />17
<br />18 19 20 21 22 23
<br />24
<br />25 26 27
<br />28 29 30 31 32 33
<br />4x8
<br />4x4
<br />8x8
<br />3x4
<br />3x10
<br />3x4 3x4
<br />3x4
<br />2x4
<br />5x8
<br />3x10
<br />4x10
<br />6x8
<br />2x4
<br />2-8-0
<br />6-3-9
<br />6-3-9
<br />12-3-10
<br />6-0-0
<br />16-6-4
<br />4-2-10
<br />19-2-4
<br />2-8-0
<br />24-3-11
<br />5-1-7
<br />30-7-4
<br />6-3-9
<br />6-3-9
<br />6-3-9
<br />12-3-10
<br />6-0-0
<br />16-6-4
<br />4-2-10
<br />19-2-4
<br />2-8-0
<br />24-3-11
<br />5-1-7
<br />30-7-4
<br />6-3-9
<br />2-
<br />9
<br />-
<br />1
<br />2
<br />2-
<br />4
<br />-
<br />3
<br />7-
<br />0
<br />-
<br />8
<br />3-
<br />5
<br />-
<br />4
<br />0.25 12
<br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [10:0-3-9,0-2-0], [11:0-4-0,0-3-4]
<br />LOADING (psf)
<br />TCLL
<br />TCDL
<br />BCLL
<br />BCDL
<br />20.0
<br />15.0
<br />0.0 *
<br />10.0
<br />SPACING-
<br />Plate Grip DOL
<br />Lumber DOL
<br />Rep Stress Incr
<br />Code
<br />2-0-0
<br />1.25
<br />1.25
<br />YES
<br />IBC2021/TPI2014
<br />CSI.
<br />TC
<br />BC
<br />WB
<br />Matrix-MS
<br />0.84
<br />0.75
<br />0.84
<br />DEFL.
<br />Vert(LL)
<br />Vert(CT)
<br />Horz(CT)
<br />Wind(LL)
<br />in
<br />-0.21
<br />-0.80
<br />0.16
<br />0.15
<br />(loc)
<br />12-13
<br />12-13
<br />9
<br />12-13
<br />l/defl
<br />>999
<br />>453
<br />n/a
<br />>999
<br />L/d
<br />360
<br />240
<br />n/a
<br />240
<br />PLATES
<br />MT20
<br />Weight: 181 lb FT = 20%
<br />GRIP
<br />220/195
<br />LUMBER-
<br />TOP CHORD 2x6 DF No.2 G
<br />BOT CHORD 2x4 DF No.1&Btr G
<br />WEBS 2x4 DF Std G *Except*
<br />9-17: 2x6 DF No.2 G, 8-10: 2x4 DF No.1&Btr G
<br />BRACING-
<br />TOP CHORD Structural wood sheathing directly applied or 3-6-6 oc purlins,
<br />except end verticals.
<br />BOT CHORD Rigid ceiling directly applied or 8-2-7 oc bracing.
<br />WEBS 1 Row at midpt 3-15
<br />REACTIONS.(lb/size)15=1444/0-2-11, 9=1377/0-5-8
<br />Max Horz 15=195(LC 11)
<br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-15=-465/81, 3-20=-2816/363, 20-21=-2810/364, 4-21=-2810/365, 4-22=-3862/649,
<br />22-23=-3858/649, 23-24=-3857/649, 5-24=-3856/649, 5-25=-3590/735, 6-25=-3586/736,
<br />6-26=-3568/733, 7-26=-3562/734, 7-27=-2319/648, 8-27=-2314/649, 8-9=-1310/308
<br />BOT CHORD 15-28=-557/2810, 14-28=-557/2810, 14-29=-669/3857, 13-29=-669/3857,
<br />13-30=-581/3593, 12-30=-581/3593, 12-31=-581/3593, 11-31=-581/3593,
<br />11-32=-386/2314, 10-32=-386/2314
<br />WEBS 3-15=-2966/407, 3-14=-47/652, 4-14=-1152/309, 5-13=-98/602, 6-11=-594/192,
<br />7-11=-322/1461, 7-10=-1046/277, 8-10=-443/2509, 5-12=-110/287
<br />NOTES-(12)
<br />1) Unbalanced roof live loads have been considered for this design.
<br />2) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed;
<br />MWFRS (envelope) and C-C Corner(3) 0-0-0 to 15-0-0, Exterior(2) 15-0-0 to 15-4-7, Corner(3) 15-4-7 to 30-4-7 zone; cantilever left
<br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
<br />DOL=1.33 plate grip DOL=1.33
<br />3) Provide adequate drainage to prevent water ponding.
<br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />will fit between the bottom chord and any other members.
<br />6) A plate rating reduction of 20% has been applied for the green lumber members.
<br />7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 15.
<br />8) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all
<br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads.
<br />9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 23 lb down at 5-4-15, and 23 lb
<br />down at 5-4-15 on top chord. The design/selection of such connection device(s) is the responsibility of others.
<br />10) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1.
<br />11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
<br />12) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC.
<br />LOAD CASE(S) Standard
<br />Continued on page 2
<br />August 27,2025
|