Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />A12 <br />Truss Type <br />Monopitch <br />Qty <br />1 <br />Ply <br />1 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895400 <br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:08 2025 Page 1 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-Xszap7?8C4HXCvBiBOGLgHscFgXJCYvMNQzKEjyjuGX <br />Scale = 1:50.8 <br />12 3 4 5 6 7 8 <br />16 15 14 13 12 11 10 9 <br />17 <br />18 19 20 21 22 23 <br />24 <br />25 26 27 <br />28 29 30 31 32 33 34 35 <br />5x6 <br />4x4 <br />8x8 <br />4x4 <br />3x10 <br />3x5 3x4 <br />3x4 <br />2x4 <br />8x8 <br />4x8 <br />4x10 <br />6x8 <br />2x4 <br />2-8-0 <br />6-3-9 <br />6-3-9 <br />12-3-10 <br />6-0-0 <br />16-6-4 <br />4-2-10 <br />19-2-4 <br />2-8-0 <br />24-3-11 <br />5-1-7 <br />30-7-4 <br />6-3-9 <br />6-3-9 <br />6-3-9 <br />12-3-10 <br />6-0-0 <br />16-6-4 <br />4-2-10 <br />19-2-4 <br />2-8-0 <br />24-3-11 <br />5-1-7 <br />30-7-4 <br />6-3-9 <br />2- <br />9 <br />- <br />1 <br />2 <br />2- <br />4 <br />- <br />3 <br />7- <br />0 <br />- <br />8 <br />3- <br />5 <br />- <br />4 <br />0.25 12 <br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [10:0-3-9,0-2-0], [11:0-4-0,0-4-8] <br />LOADING (psf) <br />TCLL <br />TCDL <br />BCLL <br />BCDL <br />20.0 <br />15.0 <br />0.0 * <br />10.0 <br />SPACING- <br />Plate Grip DOL <br />Lumber DOL <br />Rep Stress Incr <br />Code <br />2-0-0 <br />1.25 <br />1.25 <br />YES <br />IBC2021/TPI2014 <br />CSI. <br />TC <br />BC <br />WB <br />Matrix-MS <br />0.56 <br />0.82 <br />0.75 <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in <br />-0.18 <br />-0.82 <br />0.14 <br />0.13 <br />(loc) <br />12-13 <br />12-13 <br />9 <br />12-13 <br />l/defl <br />>999 <br />>442 <br />n/a <br />>999 <br />L/d <br />360 <br />240 <br />n/a <br />240 <br />PLATES <br />MT20 <br />Weight: 203 lb FT = 20% <br />GRIP <br />220/195 <br />LUMBER- <br />TOP CHORD 2x6 DF No.2 G <br />BOT CHORD 2x6 DF No.2 G <br />WEBS 2x4 DF Std G *Except* <br />9-17: 2x6 DF No.2 G, 8-10: 2x4 DF No.1&Btr G <br />BRACING- <br />TOP CHORD Structural wood sheathing directly applied or 3-4-0 oc purlins, <br />except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />WEBS 1 Row at midpt 3-15, 4-14 <br />REACTIONS.(lb/size)15=1571/0-2-11, 9=1553/0-5-8 <br />Max Horz 15=193(LC 9) <br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-15=-467/78, 3-20=-3192/68, 20-21=-3187/70, 4-21=-3187/71, 4-22=-4560/79, <br />22-23=-4555/80, 23-24=-4555/80, 5-24=-4554/80, 5-25=-4361/81, 6-25=-4357/82, <br />6-26=-4340/80, 7-26=-4336/81, 7-27=-2750/282, 8-27=-2745/282, 8-9=-1471/130 <br />BOT CHORD 15-28=-257/3186, 14-28=-257/3186, 14-29=-100/4547, 13-29=-100/4547, 13-30=0/4362, <br />30-31=0/4362, 12-31=0/4362, 12-32=0/4362, 11-32=0/4362, 11-33=-22/2745, <br />33-34=-22/2745, 10-34=-22/2745 <br />WEBS 3-15=-3341/83, 3-14=0/748, 4-14=-1488/14, 4-13=-52/303, 5-13=-202/515, <br />6-11=-536/140, 7-11=0/1847, 7-10=-1242/125, 8-10=-45/2956 <br />NOTES-(10) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; <br />MWFRS (envelope) and C-C Corner(3) 0-0-0 to 15-0-0, Exterior(2) 15-0-0 to 15-4-7, Corner(3) 15-4-7 to 30-4-7 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.33 plate grip DOL=1.33 <br />3) Provide adequate drainage to prevent water ponding. <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />6) A plate rating reduction of 20% has been applied for the green lumber members. <br />7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 15. <br />8) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all <br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads. <br />9) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />10) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC. <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Uniform Loads (plf) <br />Vert: 1-2=-30, 2-8=-70, 9-16=-20 <br />Continued on page 2 <br />August 27,2025