Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />A16 <br />Truss Type <br />Monopitch <br />Qty <br />1 <br />Ply <br />1 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895404 <br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:12 2025 Page 1 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-PdC5fV2eFIozhWUUQEKHq70GRHuK8MDyI2xYNUyjuGT <br />Scale = 1:51.1 <br />1 2 3 4 <br />5 6 7 8 <br />16 15 14 13 12 11 10 9 <br />17 18 <br />19 20 21 22 23 24 <br />25 26 27 28 29 30 31 32 33 <br />5x6 <br />4x6 <br />8x8 4x10 <br />3x4 <br />3x10 <br />3x5 3x4 <br />3x4 2x4 <br />8x8 <br />4x8 <br />4x10 2x4 <br />2-8-0 <br />6-3-9 <br />6-3-9 <br />12-3-10 <br />6-0-0 <br />16-6-4 <br />4-2-10 <br />19-2-4 <br />2-8-0 <br />24-3-11 <br />5-1-7 <br />30-7-4 <br />6-3-9 <br />6-3-9 <br />6-3-9 <br />12-3-10 <br />6-0-0 <br />16-6-4 <br />4-2-10 <br />19-2-4 <br />2-8-0 <br />24-3-11 <br />5-1-7 <br />30-7-4 <br />6-3-9 <br />2- <br />9 <br />- <br />1 <br />2 <br />3- <br />5 <br />- <br />6 <br />0.25 12 <br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [8:0-3-8,0-2-0], [10:0-3-9,0-2-0], [11:0-4-0,0-4-8] <br />LOADING (psf) <br />TCLL <br />TCDL <br />BCLL <br />BCDL <br />20.0 <br />15.0 <br />0.0 * <br />10.0 <br />SPACING- <br />Plate Grip DOL <br />Lumber DOL <br />Rep Stress Incr <br />Code <br />2-0-0 <br />1.25 <br />1.25 <br />YES <br />IBC2021/TPI2014 <br />CSI. <br />TC <br />BC <br />WB <br />Matrix-MS <br />0.68 <br />0.81 <br />0.73 <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in <br />-0.19 <br />-0.82 <br />0.13 <br />0.19 <br />(loc) <br />12-13 <br />12-13 <br />9 <br />12-13 <br />l/defl <br />>999 <br />>444 <br />n/a <br />>999 <br />L/d <br />360 <br />240 <br />n/a <br />240 <br />PLATES <br />MT20 <br />Weight: 193 lb FT = 20% <br />GRIP <br />220/195 <br />LUMBER- <br />TOP CHORD 2x6 DF No.2 G <br />BOT CHORD 2x6 DF No.2 G <br />WEBS 2x4 DF Std G *Except* <br />8-10: 2x4 DF No.1&Btr G <br />BRACING- <br />TOP CHORD Structural wood sheathing directly applied or 3-4-6 oc purlins, <br />except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. <br />WEBS 1 Row at midpt 3-15, 4-14 <br />REACTIONS.(lb/size)15=1724/0-2-11, 9=1548/0-5-8 <br />Max Horz 15=87(LC 31) <br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-15=-638/0, 2-17=-273/223, 3-17=-464/421, 3-18=-3159/128, 4-18=-3154/355, <br />4-19=-4507/49, 19-20=-4503/97, 20-21=-4502/127, 5-21=-4502/175, 5-22=-4348/128, <br />6-22=-4344/0, 6-23=-4328/0, 7-23=-4322/202, 7-24=-2783/114, 8-24=-2778/276, <br />8-9=-1473/234 <br />BOT CHORD 15-25=-1622/3605, 25-26=-1622/3605, 14-26=-1622/3605, 14-27=-1196/4493, <br />13-27=-1196/4493, 13-28=-676/4348, 28-29=-676/4348, 12-29=-676/4348, <br />12-30=-676/4348, 11-30=-676/4348, 11-31=-372/2778, 31-32=-372/2778, <br />10-32=-372/2778 <br />WEBS 3-15=-3292/556, 3-14=-88/737, 4-14=-1473/383, 4-13=-69/389, 5-13=-596/540, <br />6-11=-521/225, 7-11=-339/1795, 7-10=-1251/312, 8-10=-373/3037, 5-12=-142/269 <br />NOTES-(13) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; <br />MWFRS (envelope) and C-C Corner(3) 0-0-0 to 15-0-0, Exterior(2) 15-0-0 to 15-5-8, Corner(3) 15-5-8 to 30-5-8 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.33 plate grip DOL=1.33 <br />3) Provide adequate drainage to prevent water ponding. <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />6) A plate rating reduction of 20% has been applied for the green lumber members. <br />7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 15. <br />8) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all <br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads. <br />9) This truss has been designed for a total drag load of 2000 lb. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist <br />drag loads along bottom chord from 0-0-0 to 2-0-0 for 1000.0 plf. <br />10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 60 lb down at 3-3-12, 60 lb <br />down at 3-3-12, and 60 lb down at 0-3-12, and 60 lb down at 0-3-12 on top chord. The design/selection of such connection <br />device(s) is the responsibility of others. <br />11) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). <br />Continued on page 2 <br />August 27,2025