Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />A21 <br />Truss Type <br />Monopitch <br />Qty <br />1 <br />Ply <br />1 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895409 <br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:17 2025 Page 1 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-mb0_iC6n4rQGoINRDnwSXAk9XIeypZ5hSKeJ3iyjuGO <br />Scale = 1:52.4 <br />12 3 4 <br />5 6 7 8 <br />16 15 14 13 12 11 10 9 <br />17 18 <br />19 20 <br />21 22 23 24 <br />25 26 27 28 29 30 <br />4x6 <br />4x4 8x8 8x14 <br />4x6 8x8 <br />3x8 <br />3x4 3x4 <br />3x4 2x4 3x10 <br />4x8 2x4 <br />4x6 <br />2-8-0 <br />6-3-9 <br />6-3-9 <br />12-3-10 <br />6-0-0 <br />16-6-4 <br />4-2-10 <br />19-2-4 <br />2-8-0 <br />19-5-13 <br />0-3-9 <br />24-3-11 <br />4-9-14 <br />30-7-4 <br />6-3-9 <br />6-3-9 <br />6-3-9 <br />12-3-10 <br />6-0-0 <br />16-6-4 <br />4-2-10 <br />19-2-4 <br />2-8-0 <br />24-3-11 <br />5-1-7 <br />30-7-4 <br />6-3-9 <br />2- <br />9 <br />- <br />1 <br />2 <br />3- <br />5 <br />- <br />6 <br />0- <br />1 <br />0 <br />- <br />8 <br />3- <br />5 <br />- <br />6 <br />0.25 12 <br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [8:0-5-4,0-4-4], [9:Edge,0-3-9], [10:0-3-9,0-2-0], [11:0-4-0,0-4-8] <br />LOADING (psf) <br />TCLL <br />TCDL <br />BCLL <br />BCDL <br />20.0 <br />15.0 <br />0.0 * <br />10.0 <br />SPACING- <br />Plate Grip DOL <br />Lumber DOL <br />Rep Stress Incr <br />Code <br />2-0-0 <br />1.25 <br />1.25 <br />YES <br />IBC2021/TPI2014 <br />CSI. <br />TC <br />BC <br />WB <br />Matrix-MS <br />0.53 <br />0.65 <br />0.95 <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in <br />-0.18 <br />-0.65 <br />0.09 <br />0.13 <br />(loc) <br />12-13 <br />12-13 <br />18 <br />12-13 <br />l/defl <br />>999 <br />>560 <br />n/a <br />>999 <br />L/d <br />360 <br />240 <br />n/a <br />240 <br />PLATES <br />MT20 <br />Weight: 196 lb FT = 20% <br />GRIP <br />220/195 <br />LUMBER- <br />TOP CHORD 2x6 DF No.2 G <br />BOT CHORD 2x6 DF No.2 G <br />WEBS 2x4 DF Std G <br />OTHERS 2x6 DF No.2 G <br />BRACING- <br />TOP CHORD Structural wood sheathing directly applied or 3-8-14 oc purlins, <br />except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 9-3-2 oc bracing. <br />WEBS 1 Row at midpt 3-15 <br />REACTIONS.(lb/size)15=1378/0-2-11, 18=1322/0-5-8 <br />Max Horz 15=42(LC 9) <br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-15=-469/76, 3-20=-2719/502, 4-20=-2714/502, 4-21=-3828/693, 5-21=-3823/693, <br />5-22=-3602/649, 6-22=-3598/649, 6-23=-3582/645, 7-23=-3577/646, 7-24=-2322/417, <br />8-24=-2317/418, 9-17=0/422, 8-17=0/422 <br />BOT CHORD 15-25=-530/2714, 14-25=-530/2714, 14-26=-722/3820, 13-26=-722/3820, <br />13-27=-671/3602, 12-27=-671/3602, 12-28=-671/3602, 11-28=-671/3602, <br />11-29=-431/2317, 10-29=-431/2317, 10-30=-59/254, 9-30=-59/254 <br />WEBS 3-15=-2840/499, 3-14=0/649, 4-14=-1211/221, 5-13=-143/550, 6-11=-498/144, <br />7-11=-270/1463, 7-10=-1052/286, 8-10=-420/2327, 8-18=-1349/245 <br />NOTES-(11) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; <br />MWFRS (envelope) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members <br />and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 <br />3) Provide adequate drainage to prevent water ponding. <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />6) A plate rating reduction of 20% has been applied for the green lumber members. <br />7) Bearing at joint(s) 18 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify <br />capacity of bearing surface. <br />8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 15. <br />9) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all <br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads. <br />10) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />11) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC. <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Continued on page 2 <br />August 27,2025