Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />A01 <br />Truss Type <br />MONOPITCH <br />Qty <br />1 <br />Ply <br />2 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895389 <br />8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:51:01 2025 Page 2 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-GLYCzg0CMBAa4yoED0KQ9B7SN5KNqtZ0aVem4XyjuKO <br />NOTES-(17) <br />12) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all panel points along the Top Chord and <br />Bottom Chord, nonconcurrent with any other live loads. <br />13) Use Simpson Strong-Tie LUS24 (4-10d Girder, 2-10d Truss) or equivalent spaced at 2-0-0 oc max. starting at 1-1-0 from the left end to 27-1-0 to connect truss(es) to <br />back face of bottom chord. <br />14) Use Simpson Strong-Tie MUS26 (6-10d Girder, 4-10d Truss) or equivalent at 29-1-0 from the left end to connect truss(es) to back face of bottom chord. <br />15) Fill all nail holes where hanger is in contact with lumber. <br />16) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />17) This truss has been designed in conformance with Section 2303.4 of the 2022 CBC. <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Uniform Loads (plf) <br />Vert: 1-2=-30, 2-7=-70, 8-14=-20 <br />Concentrated Loads (lb) <br />Vert: 22=-73(B) 23=-73(B) 24=-73(B) 25=-73(B) 26=-73(B) 27=-73(B) 28=-73(B) 29=-73(B) 30=-73(B) 31=-73(B) 32=-73(B) 33=-73(B) 34=-69(B) 35=-69(B) <br />36=-69(B)